W ater Heater s Electric P oint of Use Model: GE Series The purpose of this manual is twofold: one , to provide the installer with basic dir ections and r ecommendations f or the pr oper installation .
Safety Information S afety P recautions . . . . . . 3, 4 Installation Instructions Location . . . . . . . . . . . . . . . . . . 5 Wa ter Connections . . . . . . . . . 6 Electrical Connections . . . . . . 8 Pipe Insulation . . . . . . . . . . . . 10 Heat T raps .
Safety Instructions Installation Instructions Operating Instructions Care and Cleaning T roubleshooting Tips Customer Service Time/T emperature Relationship in Scalds W ater T emperature Time T o Prod.
4 IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING. W ARNING! F or your safety , the information in this manual must be f ollowed to minimize the risk of fir e or explosion, electric shock, or to pr event pr oper ty damage, personal injur y , or loss of life .
Installing the water heater . The location chosen f or the water heater must take into consider ation the f ollowing: Local Installation Regulations This water heater must be installed in accor dance .
Installing the water heater . Thermal Expansion W ater Supply Connections Determine if a check valve exists in the inlet water line. It may hav e been installed in the cold water line as a separ ate back flow pr eventer , or it may be par t of a pressur e r educing valv e, water meter or water sof tener .
T ypical Installation Recommended heat trap 6 ″ minimum Hot water outlet to fixtures 6 ″ air gap Suitable open drain 6 ″ Union T emperature & pressure relief valve Cold water supply T o cold.
CAUTION: The presence o f water in the piping and water heater does not provide sufficient conduction for a ground. Non-metallic piping, dielectric unions, flexible connectors etc. can cause the water heater to be electrically isolated. T o Fill the W ater Heater Make cer tain the dr ain valv e is completely closed.
9 NOTICE: This guide recommends minimum branch circuit sizing and wire size based on National Electric Code. Refer to wiring diagrams in this manual for field wiring connections. Insulation blankets , available to the gener al public, f or external use on electric water heaters ar e not necessary.
10 Installing the water heater . Hot and Cold Pipe Insulation Installation F or increased ener gy efficiency , some water heaters hav e been supplied with two 24” sections of pipe insulation. Please install the insulation, accor ding to the illustr ations above , that best meets your r equir ements .
11 Safety Instructions Installation Instructions Operating Instructions Care and Cleaning T roubleshooting Tips Customer Service Installation checklist. W ater Heater Location ■ Close to ar ea of heated water demand. ■ Indoors and protected from fr eezing tempera tures .
Customer Service T roubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions 12 Safety Precautions Do turn off power to water hea ter if it has been subjected to over heating, fir e, flood, physical damage.
13 If adjustment is necessary… T urn off the power to the water heater . Remove the jacket access panel(s) and insulation exposing the thermostat(s). The thermostat protectiv e cov er(s) should not be r emoved. Using a small scr ewdriv er , set the thermostat(s) dial pointer(s) to the desir ed tempera ture .
Routine Preventative Maintenance P roperly maintained, your water hea ter will provide years of dependable tr ouble- fr ee ser vice. It is suggested that a r outine prev entiv e maintenance progr am be established and follow ed by the user .
Problem Possible Causes What T o Do Rumbling noise W ater conditions in your ● Remov e and clean the heating elements . home caused a build up of scale or miner al deposits on the heating elements . Relief valve P r essure build up caused ● This is an unacceptable condition and must be producing popping by thermal expansion corr ected.
Customer Service T roubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions Replacement P arts. F or 2 1 / 2 gallon models and 6, 10 & 20 gallon models with single elements . Instructions F or Placing a Parts Order T o place or ders using a Visa/MasterCar d call 800-431-1549.
2 1 2 THERMOST A T & HIGH TEMP . HEA T ING ELEMENT WHITE BLACK BLACK H G TO PROPERL Y GROUNDED RECEPT A CLE ON BRANCH CIRCUIT JUNCTION BOX N 1 2 1 2 THERMOST A T & HIGH TEMP . LIMIT (ECO) HEA TING ELEMENT WHITE BLACK BLACK H BRANCH CIRCUIT T O ELECTRICAL DISTRIBUTION P ANEL JUNCTION BO X N 1 G* 17 Wiring diagrams.
18 Notes. Customer Service T roubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions.
19 Rheem Manufacturing Company W arr anty Registr ation D epar tment P .O. Box 34070 Louisville, KY 40232-4070 Please place in envelope and mail to: ✁ Cut here ✁ Cut here.
20 ✁ Cut here Consumer Product Ownership Registration F ollow these three steps to protect your new appliance investment: If you require service, call 800-431-1549. 12 3 Model Number Serial Number Consumer Product Ownership Registration Model Number W ater Heater Serial Number Important Mail T oday! First Name Mr .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté GE AP12169-5 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du GE AP12169-5 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation GE AP12169-5, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le GE AP12169-5 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le GE AP12169-5, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du GE AP12169-5.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le GE AP12169-5. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei GE AP12169-5 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.