Air Conditioners Room
Safety Instructions 2, 3 Operating Instructions Additional Controls 7 Control Knob Models 6 Normal Operating Sounds 7 Touch Pad Models 4, 5
Care and Cleaning Air Filter 8 Grille and Case 8 Outdoor Coils 8
Installation Instructions Through-the-Wall Installation—Optional 15 Window Installation 9–14
Manuel d’utilisation et instructions d’installation
Consumer Support Consumer Support Back Cover Ownership Registration for Customers in Canada only 17, 18 Warranty for Customers in Canada 20 Warranty for Customers in the U.S.A 19
La section française commence à la page 21
de aire
*ENERGY STAR® labeled product
y instrucciones de
instalación
La sección en español empieza en la página 41
As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.
Write the model and serial numbers here:
Find these numbers on a label on the side of the air conditioner.
Model # · Serial #

purpose as described in this Owner’s Manual.
the receptacle must be changed out by a qualified electrician.
installed in accordance with the Installation Instructions before it is used.
conditioner before making any repairs or cleaning.
on the power cord. Always grip plug firmly and pull straight out from the receptacle.
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
EXTENSION CORDS

About the controls on the air conditioner—models with touch pads.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
Light indicates the unit is in the temperature or delay time Set mode.
The display always shows the room temperature except when setting the Set temperature or the Delay timer.
Light indicates the delay timer is set.
F
Fan speed Decrease Temperature set Increase and Decrease
Light indicates Circulaire is on.
Remote Control
Controls
The air conditioner controls are located behind the control panel door. Press to open and close the door.
Mode Pad Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.
Delay Pads Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.
Power Pad Turns air conditioner on and off. When turned on, the display will show the room temperature.
Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.
Display Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.
How to set:
Press the Delay 1–24hr pad on the unit or the pad on the remote control. Each touch of the Increase ▲/ Decrease ▼ pads on the unit or the Increase + / Decrease – pads on the remote control will set the timer in 1-hour intervals. The Set light will turn on while setting.
Temp Increase ▲ /Decrease ▼ Pads Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while setting.
To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the unit or the pad on the remote control. Use the Increase ▲ / Decrease ▼ pads on the unit or the Increase + / Decrease – pads on the remote control to set a new time if desired.
Delay Timer Increase ▲ (+) /Decrease ▼ (–) Pads Each touch of the Increase ▲ / Decrease ▼ pads on the unit or the Increase + / Decrease – pads on the remote control will set the delay time when using the Delay 1–24hr timer ( ). The Set light will turn on while setting.
To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes off.
Turn on to provide continuous side-to-side air circulation.
Fan Speed Pads Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + / Decrease – pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto fan on.
For fixed side-to-side air direction, turn on until the desired air direction is obtained, then turn it off.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.
Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase ▲/ Decrease ▼pads to set the desired temperature between 64°F and 86°F in 1°F increments.
For Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.
An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
For Quieter & Nighttime Cooling—Select the Cool mode and Low fan with a middle set temperature.
Controls the fan.
ON—The fan will cycle on and off with the compressor. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan may continue to run for a short time after the compressor cycles off.
OFF—The fan runs all the time, while the compressor cycles on and off.
Auto Fan Speed
Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.
Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.
In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is restored. If the Delay 1–24hr
feature was set, it will resume countdown. You may need to set a new time if desired.
control at the signal receiver on the air conditioner.
and the remote control that could block the signal.
up to 20 feet.
correctly as indicated on the remote control.

About the controls on the air conditioner—models with control knobs.
Features and appearance will vary.
TEMPERATURE CONTROL (on some models)
OFF
1 TEMP
The air conditioner controls are located behind the control panel door. Press to open and close the door.
TEMP Control The TEMP control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer. CIRCULAIRE For continuous side-to-side air circulation, set the Circulaire switch to ON.
Mode Control High Cool, Med Cool and Low Cool provide cooling with different fan speeds. Fan settings provide air circulation and filtering without cooling. NOTE: If you move the mode control from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.
For fixed side-to-side air direction, set the Circulaire switch to ON until the desired air direction is obtained, then move it to OFF.
For Normal Cooling—Select High Cool or Med Cool with the TEMPERATURE control at midpoint. For Maximum Cooling—Select High Cool with the TEMPERATURE control at the highest number available on your knob. For Quieter & Nighttime Cooling—Select Low Cool with the TEMPERATURE control at midpoint.
MODE CONTROL (on some models)
Heating Descriptions For Normal Heating—Select Hi Heat or Low Heat with the temp control at midpoint. For Maximum Heating—Select Hi Heat with the temp control turned counterclockwise as far as possible. For Quieter & Nighttime Heating—Select Low Heat with the temp control at midpoint.
The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. Turn the knob clockwise to Cooler (blue) and indoor air will become cooler. Turn knob counterclockwise to Warmer (red) and the indoor air will become warmer.
Circulaire For continuous side-to-side air circulation, set the Circulaire switch to On. For fixed side-to-side air direction, set the Circulaire switch to On until the desired air direction is obtained, then move it to Off.
Hi Cool and Low Cool provide cooling with different fan speeds. Hi Heat and Low Heat provide heating with different fan speeds. Fan Only setting provides air circulation and filtering without cooling or heating. NOTE: If you move the mode control from a cool setting to Off, a fan setting or a heat setting, wait at least 3 minutes before switching back to a cool setting. Cooling Descriptions For Normal Cooling—Select Hi Cool or Low Cool with the temp control at midpoint. For Maximum Cooling—Select Hi Cool with the temp control turned clockwise as far as possible. For Quieter & Nighttime Cooling—Select Low Cool with the temp control at midpoint.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
The vent control is located above the control panels.
When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some outside air is let into the room.
To open the vent, push the lever to the right. To close it, push it to the left.
Fingertip pressure on the horizontal louvers adjusts the air direction up or down.
Press to open and close the door.
Normal operating sounds.
water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
does not.
compressor cycles on and off.

Care and cleaning of the air conditioner.
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove:
Open the inlet grille upward by pulling out the bottom of the inlet grille.
Using the tab, pull up slightly on the filter to release it and pull it down.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher. CAUTION: DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.
Grille Frame Removal (if necessary for coil cleaning)
Remove the air filter. See the Air Filter section above. If present, remove the grille frame attachment screw.
Grasp the lower corners of the grille frame while pressing in on the case side tabs with your finger tips. Pull out to release and lift it up.
Remove the battery cover by sliding it according to the arrow direction.
Insert new batteries, making sure that the (+) and (–) of battery are installed correctly.
use rechargeable batteries.
the system is not going to be used for a long time. 3
Reattach the cover by sliding it back into position.

Questions? Call 800.GE.CARES (800.432.2737) or visit our Website at: ge.com In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
Read these instructions completely and carefully.
Ruler or tape measure Pencil
Level Scissors or knife
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Adjustable wrench · Phillips head screwdriver · Flat-blade screwdriver


Type B (4) Type C (7) Type D (6) Type E (4)


ATTACH THE TOP MOUNTING RAIL SEAL STRIP Remove the backing from the top mounting rail seal strip and attach the seal strip to the bottom of the top mounting rail, along the front edge.
18″ min.
30″ to 41″ (With accordion panels)
STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool. WOOD PIECES WIDTH: 2″ LENGTH: Long enough to fit inside the window frame. THICKNESS: To determine the thickness, place a piece of wood on the sill to make it 1/2″ higher than the top of the storm window frame or the vinyl frame. Attach securely with nails or screws provided by the installer.
Remove the locking screw and locking bracket from the lower frame. Save to reinstall later.
Remove the ground screw and save to reinstall later.
Remove the ground screw and save to reinstall later
Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case.
1/2″ higher than vinyl frame (on some windows)
1/2″ higher than storm window frame


PREPARE THE WINDOW Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.
INSTALL THE CASE IN THE WINDOW Carefully slide the case into the window and center the case. Lower the window behind the top mounting rail. Pull the bottom of the case forward so that the bottom mounting rail is tight against the back of the window sill. Mount the case to the window sill using 4 type E screws. Drill pilot holes, if necessary.
4 type E screws
Install the top mounting rail with 4 type B screws from the inside of the case.
Make sure the bolts and nuts are all of the way in both the left and right V-supports.
Position the V-supports on the case bottom so that they will be near the outside wall. Attach a V-support to each side of the bottom of the case using type C screws, 3 on each side.
Insert the frames for the accordion panels into the top mounting rail and the bottom frame guides. Attach the accordion panels to the side of the case using 3 type A screws on each side.
Sill · Bolt and nut · V-support


INSTALL THE CASE IN THE WINDOW (cont.) Use a wood block (obtained locally) between the leveling bolts and the wall if the wall is weak or if the weight of the air conditioner falls between the studs in the wall.
A CAUTION: To prevent broken glass or damage to windows, on vinyl or other similarly constructed windows, attach the support bracket to the window side jam.
Drill pilot holes and attach the support brackets with two type D screws, one on each side.
Adjust the leveling bolts and nuts against the outside wall so that the case has a slight tilt to the outside. Tighten nuts with an adjustable wrench. Use a level; no more than a 1/2 bubble will be the correct case slant to the outside.
Cut the foam top window gasket to the window width.
Stuff the foam between the glass and the window to prevent air and insects from getting into the room. NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.
Extend the left and right accordion panels to the vertical window sashes. Drill pilot holes and attach the top and bottom corners with 4 type D screws.
Type D screw Type D screw
Top mounting rail · Type D screw · Type D screw

INSTALL THE AIR CONDITIONER IN THE CASE Make sure the ground wire is off to the side and slide the air conditioner into the case. Do not push on the controls or the finned coils. Make sure the air conditioner is firmly seated.
A
G
Pull the coiled power cord from its shipped position in the air discharge area. Attach the front grille frame to the case by inserting the tabs on the grille frame into the slots on the front top of the case.
Reinstall the locking bracket and screw removed earlier.
Guide the lever carefully through the grille frame as you push it in.
Press the grille frame in around the power cord on the right side. Secure the grille with a type F (painted) screw on each side and a type C screw in the front.
Reconnect the ground wire to the air conditioner using the screw removed earlier. IMPORTANT: The ground wire must be reinstalled to ensure a proper ground.
Press the ground wire against the unit to prevent it from being pinched when installing the front grille
Reinstall the filter.
Remove the front grille from its box and remove the shipping tape.
Grasp the inlet grille at the bottom corners and pull it forward. Unhook it from its top hinges and set it aside.
Reinstall the inlet grille. Connect power.
Using the tab, pull up slightly on the filter to release it and pull it down and out. F
Caulk or weather-strip any gaps or openings to the outside to seal the installation.
Type F screw · Type F screw · Type C screw

The case may be installed through-the-wall in both existing and new construction. Read completely, then follow step-by-step. NOTE: Except for the V-support assemblies (included), obtain all materials locally for mounting the air conditioner through-the-wall.
Install the V-supports. See the INSTALL THE CASE IN THE WINDOW section in the Window Installation Instructions.
FINISH THE WALL OPENING Caulk all four sides on the outdoor side of the case to prevent moisture from getting through to the interior wall. Use of flashing (drip rail) will further prevent water from dripping inside the wall and down the outside of the building.
All side and top louvers in the case must project on the outdoor side of the wall.
The room side of the case must project into the room far enough to maximize the balance of the unit.
The case must be installed level from side- to-side and with a slight tilt from front to rear. Use a level; no more than a 1/2 bubble will be the correct case slant to the outside.
Lintel angle is required to support bricks or blocks above opening.
Trim molding (if desired)
Flashing is required and should extend the length of the opening to ensure no inside cavity leakage occurs.
INSIDE
A
Remove the air conditioner from the case. For specific instruction, refer to the Window Installation Instructions.
Air louvers (top and sides must project on the outdoor side of the wall)
Make certain that a wall receptacle is available close to the hole location or make arrangements to install a receptacle.
Wood filler and caulking (above and below the flashing)
Flashing (Drip rail) Wood support strips
Place the case in the wall opening and place wood support strips between the case bottom and the flashing on both sides of the bottom rail. They should be the same height as the bottom rail and the same length as the wall opening.
Place the air conditioner into the case. For specific instruction, refer to the Window Installation Instructions.

Troubleshooting Tips.
Air conditioner The air conditioner • Make sure the air conditioner plug is pushed completely does not start is unplugged. into the outlet.
The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.
Air conditioner does not Airflow is restricted. • Make sure there are no curtains, blinds or furniture cool as it should blocking the front of the air conditioner.
The air filter is dirty. • Clean the filter at least every 30 days. See the Care and Cleaning section.
The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cooling coils have iced up. • See “Air conditioner freezing up” below.
The remote control The batteries are inserted • Check the position of the batteries. They should be is not working incorrectly. inserted in the opposite (+) and (–) direction.
The batteries may be dead. • Replace the batteries.
Water drips outside Excessively hot and • This is normal. humid weather.
Water drips indoors The air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear.
Water collects in Moisture is removed from • This is normal for a short period in areas with little base pan indoor air and drains into humidity; normal for a longer period in very humid areas. rear of a cabinet where a fan blows it against the outdoor condenser coil.
Delay 1–24hr feature not A power outage or interruption • The unit will automatically re-start in the settings last used working properly occurred. after the power is restored. If the Delay 1–24hr feature was set, it will resume countdown. You may need to set a new time if desired.

Please place in envelope and mail to: Veuillez mettre dans une enveloppe et envoyez à :
(FOR CANADIAN CONSUMERS ONLY)



GE Air Conditioner—One-Year Limited Warranty. (For customers in the U.S.A.)
All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, visit us on-line at ge.com, or call 800.GE.CARES (800.432.2737). Have serial number and model number available when calling for service.
Staple your receipt here. Proof of the original purchase date is needed to obtain service
under the warranty.
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and related original purchase service to replace the defective part.
use the product.
breakers.
have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
protected.
voltage, accident, fire, floods or acts of God.
defects with this air conditioner.
the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
unit to a location where it is accessible for service by an individual technician.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. For service, call 1.800.561.3344. Please have serial number and model number available when calling for service.
Staple your receipt here. Proof of the original purchase date is needed to obtain service
under the warranty.
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, Mabe will also provide, free of charge, all labor and related original purchase service to replace the defective part.
use the product.
breakers.
have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
protected.
voltage, accident, fire, floods or acts of God.
defects with this air conditioner.
the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
unit to a location where it is accessible for service by an individual technician.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased in Canada for home use within Canada. In-home warranty service will be provided in areas where it is available and deemed reasonable by Mabe to provide.
Some provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from province to province. To know what your legal rights are in your province, consult your local or provincial consumer affairs office.
Burlington, Ontario
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| Air conditioner does not start | The air conditioner • Make sure the air conditioner plug is pushed completely is unplugged. into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker. Power failure. • The unit will automatically re-start in the settings last used after the power is restored. • There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on. The current interrupter • Press the RESET button located on the power cord plug. device is tripped. • If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. | p.16 | |
| Air conditioner does not cool as it should | Airflow is restricted. • Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner. The temp control may not • On models with touch pads: In the Cool mode, press the be set correctly. Decrease ▼ pad. •On models with control knobs, turn the temperature knob to a higher number. The air filter is dirty. • Clean the filter at least every 30 days. See the Care and Cleaning section. The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down. Cold air is escaping. • Check for open furnace floor registers and cold air returns. • Set the air conditioner’s vent to the closed position. Cooling coils have iced up. • See “Air conditioner freezing up” below. | p.16 | |
| Air conditioner freezing up | Ice blocks the air flow and • On models with control knobs, set the mode control at stops the air conditioner High Fan or High Cool with the Temp at 1 or 2. from cooling the room. •On models with touch pads, set the controls at High Fan or High Cool and set the thermostat to a higher temperature. | p.16 | |
| The remote control is not working | The batteries are inserted • Check the position of the batteries. They should be incorrectly. inserted in the opposite (+) and (–) direction. The batteries may be dead. • Replace the batteries. | p.16 | |
| Water drips outside | Excessively hot and • This is normal. humid weather. | p.16 | |
| Water drips indoors | The air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear. | p.16 | |
| Water collects in base pan | Moisture is removed from • This is normal for a short period in areas with little indoor air and drains into humidity; normal for a longer period in very humid areas. rear of a cabinet where a fan blows it against the outdoor condenser coil. | p.16 | |
| Delay 1–24hr feature not working properly | A power outage or interruption • The unit will automatically re-start in the settings last used occurred. after the power is restored. If the Delay 1–24hr feature was set, it will resume countdown. You may need to set a new time if desired. | p.16 |