MODE D’EMPLOI MANUAL DE FUNCIONAMIENTO
O PERATING M ANUAL
AIR CONDITIONER
REMOTE CONTROLLER (WIRED TYPE)
Remote Controller UTB-UUB

FUJITSU GENERAL LIMITED P/N9373329039-03
English Français Español


Depending on the indoor unit model, some buttons on this remote controller cannot be used and some functions are re- stricted. Refer to the following table for the buttons that can be used for each model.

: Button can be operated : Button cannot be operated
1 2 3 4 5 6 7 8 9 0 A B C D
If a button indicated with “ ” is pressed, the operation lock display (I on page 1) flashes, but the air conditioner will not respond.
*1: Air clean operation is always on during air conditioner operation and cannot be turned off. *2: If the wired remote controller is connected to the indoor unit, a wireless remote controller cannot be used. *3: Before connecting the remote controller, the remote controller cord must be modified. *4: The fan speed cannot be changed for some large, duct-type indoor units. *5: This button cannot be operated for the AIRSTAGE S-series remote controllers. *6: This button cannot be operated for the AIRSTAGE J-series and V-series remote controllers. *7: This button cannot be operated if the indoor unit has manually-operated horizontal airflow direction louvers.


Press the DAY button and select the current day. A appears around the selected day.
Press the TIMER MODE button for 2 seconds or more. The time display on the remote controller will flash.
Press the SET TIME buttons to set the current time. Press repeatedly to adjust the current time in 1-minute increments. Press and hold to adjust the current time in 10-minute increments.
Instructions related to heating are applicable to “HEAT PUMP MODELS” and “HEAT RECOVERY MODELS” only.
Press the START/STOP button.
G Operation mode setting
Press the MASTER CONTROL button to set the operation mode. If DRY is selected, the fan speed will be set to AUTO.
* AUTO and FAN cannot be selected for “HEAT PUMP MODELS.”
G Room temperature setting
Press the SET TEMPERATURE buttons to set the room temperature.
AUTO 64 to 88 °F COOL/DRY 64 to 88 °F HEAT 48, 52, 56, or 60 to 88 °F*
* Room temperatures as low as 48, 52, and 56 °F cannot be set depending on the model.
G Fan speed setting
Press the FAN CONTROL button to set the fan speed.
G Energy save setting
Press the ENERGY SAVE button to start or stop the energy- saving air conditioner operation. * The energy save air conditioner operation is not available depending on the model.
SAVE
Operation lamp · Temperature setting range · Lower Raise

G Vertical air direction adjustment (Swing operation)
* Press the START/STOP button to start the air conditioner, and then proceed as follows. Press the VERTICAL AIRFLOW DIRECTION button to adjust the direction of the verti- cal airflow. To set the swing operation, press the VERTICAL AIRFLOW DIRECTION button for more than 2 seconds. (Stop the setting by pressing for more than 2 sec- onds again.)
ex. Vertical swing operation
G Horizontal air direction adjustment (Swing operation)
* Press the START/STOP button to start the air conditioner, and then proceed as follows. Press the HORIZONTAL AIRFLOW DIRECTION button to adjust the direction of the horizontal airflow. To set the swing operation, press the HORIZONTAL AIRFLOW DIRECTION button for more than 2 seconds. (Stop the setting by pressing for more than 2 seconds again.)
ex. Horizontal swing operation
(1) • Always use the remote controller’s AIRFLOW DIRECTION


direction. • The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds. (3) The swing operation is not available depending on the model. Please refer to the operating manual for the in- door unit.
1 2 3 4 5
the ranges listed in the tables above. For more information, refer to the operating manual of the indoor unit.

THERMO SENSOR
Press the THERMO SENSOR button to select whether the room temperature is detected at the indoor unit (remote sensor) or the remote controller.
When the thermo sensor display appears, the room temperature is detected at the remote controller.
Press the DAY (DAY OFF) button and SET button simulta- neously for 2 seconds or more to activate the part lock function and lock all of the buttons on the remote con- troller except the Start/Stop button, Set Temperature but- tons, Master Control button, and Fan Control button. Press the buttons again for 2 seconds or more to deactivate the part lock function. When the part lock function is activated, the mark
DELETE SET
appears. If any button is pressed during the part lock, the PL display flashes.
Instructions related to heating are applicable to “HEAT PUMP MODELS” and “HEAT RECOVERY MODELS” only. The timer function is not available depending on the model.

Press the TIMER MODE button to select the ON TIMER or OFF TIMER. 2
Press the SET TIME buttons to set the time. After the time is set, the timer will start automatically. The amount of time until the OFF timer operates that is dis- played on the timer display decreases as time passes.
Indoor unit

Instructions related to heating are applicable to “HEAT PUMP MODELS” and “HEAT RECOVERY MODELS” only. The timer function is not available depending on the model.
Press the SET button for 2 seconds or more. 1
SET
3 6 9 12 15 18 21
Press the TIMER MODE button to select the weekly timer.
G Day of the week setting
DAY SET
Press the DAY button to select the day of the week, and then press the SET button to confirm the setting. * For ALL, all of the days can be set together when a appears around each day.
3 6 9 12 15 18 21
When the operating time is set, the
mark appears.
3 6 9 12 15 18 21
ex. The timer is set for 7:00 A.M.–6:00 P.M.
(7:00–18:00)
Press the SET TIME buttons to set the ON time in 30-minute increments, then press the SET button to proceed to the OFF time setting. Set the OFF time in the same way. If necessary, set the second weekly timer settings in the same way.
SET G To delete the operating time
Repeat steps 3 and 4 to set the weekly timer for another day of the week.
Press the SET button for 2 seconds or more to com- plete the weekly timer set- tings.
If the DELETE button is pressed during steps 3 or 4, the operating time for the selected day will be deleted. If all the days are selected, the operating times for all of the days will be deleted.
G Time setting

3 6 9 12 15 18 21
When the weekly timer is selected, the timer starts automatically.
ex. Operating time 7:00 A.M.
(1) PRECAUTIONS DURING WEEKLY TIMER SETUP
(2) The earliest OFF time you can set is 30 minutes after the
ON time. (3) The OFF time can be carried over to the next day. (4) Even if the timer operation is set, the timer indicator lamp
of the indoor unit does not light up. (The timer indicator lamp is used for wireless remote controllers only.)
DAY SET 3 DAY OFF
During the weekly timer, press the SET button for 2 seconds or more to set the day.
Select the day to set the DAY OFF.
Press the DAY (DAY OFF) button for 2 seconds or more to set the DAY OFF.
Press the SET button for 2 seconds or more to com- plete the DAY OFF setting.
3 6 9 12 15 18 21
Follow the same procedures as those for setup. ex. The DAY OFF is set for Monday.
3 6 9 12 15 18 21
(1) The DAY OFF setting is only available for days for which weekly settings already exist. (2) If the operating time carries over to the next day (during a next day setting), the effective DAY OFF range will be set as
shown below.
G Normal G Next day setting
WEEKLY ON OFF ON OFF
WEEKLY WEEKLY WEEKLY
Setting day Preceding day Next day Setting day Preceding day Next day
(3) The DAY OFF setting can only be set one time. The DAY OFF setting is cancelled automatically after the set day has
passed.
G To start · G To cancel · G To cancel

Instructions related to heating are applicable to “HEAT PUMP MODELS” and “HEAT RECOVERY MODELS” only. The timer function is not available depending on the model.
SET BACK SET If there is no existing SET BACK tempera- ture setting, “- -” will be displayed for the temperature.
3 6 9 12 15 18 21
Press the SET BACK button to change to the SET BACK confirmation display. The SET BACK operating time and the set temperature will be displayed.
Press the SET button for 2 seconds or more.
G Day setting G Operating time setting
SET
3 6 9 12 15 18 21
Follow steps 3 and 4 in “To set the WEEKLY timer” (p. 6). The DELETE button is also used as described in the procedures for the weekly timer. 4
G Temperature setting Press the SET TEMPERATURE buttons to set the temperature (from 48 °F to 88 °F).
3 6 9 12 15 18 21
Repeat steps 3 and 4. Press the SET button for 2 seconds or more to com- plete the temperature SET BACK timer settings.
84 ° F
ex. Operating time 3:00–10:00 P.M.
(15:00–22:00)
To start/cancel the temperature SET BACK timer operation
SET BACK
SET BACK
ex. Display during SET BACK timer operation (The operating time will not be displayed.)
Press the SET BACK button, and then press the DELETE button while the SET BACK confirmation display is dis- played. Even if the SET BACK button is pressed again, the SET BACK timer will be cancelled.
Press the SET BACK button. The SET BACK confirmation display appears for 5 seconds, and then the timer starts au- tomatically.
(1) The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner operation. (2) The SET BACK timer can be set to operate up to two times per day but only one temperature setting can be used. (3) The SET BACK timer can be used together with the ON, OFF, and weekly timer functions. (4) During the COOL/DRY mode, the air conditioner will operate at a minimum of 64 °F even if the SET BACK temperature
is set to 62 °F or lower. (5) The SET BACK operating time is displayed only in the SET BACK confirmation display. (Refer to step 1 for the SET
BACK confirmation display.) (6) Room temperatures as low as 48, 52, and 56 °F cannot be set depending on the model.

When the error indication “E:EE” is displayed, inspection of the air conditioning system is necessary. Please consult author- ized service personnel.

SU MO TU WE TH FR SA SU MO TU WE TH FR SA
Press the SET TEMPERATURE buttons simultaneously for 5 seconds or more to start the self-diagnosis.
(3) Press the SET TEMPERATURE buttons simultaneously for 5 seconds or more to stop the self-diagnosis.
Instructions related to heating are applicable to “HEAT PUMP MODELS” and “HEAT RECOVERY MODELS” only.
Weekly timer
(VRF system Heat Pump model only))
When is displayed there are functions for which set- tings cannot be made.
Use this timer function to change the set temperature in the operation times set for each day of the week. This can be used together with other timer settings.
During cooling operation When the ENERGY SAVE is pressed, the thermostat setting is automatically raised 2 °F every 60 minutes, until the thermostat is raised a total of 4 °F.

will also be displayed on the remote controller if the operation modes of the indoor unit and outdoor unit are different when the indoor unit starts operating.
During heating operation When the ENERGY SAVE is pressed, the thermostat setting is automatically lowered 2 °F every 30 minutes, until the ther- mostat is lowered a total of 8 °F.

Before requesting service, perform the following checks:
If the problem persists after performing these checks, or if you notice burning smells, immediately stop operation, turn off the electrical breaker and consult authorized service personnel.
Problèmes fréquents, causes probables et solutions.