Room Air Conditioner Ser vice and P ar ts Man ual ZStar ® ZQ05/ZQ07 (06/05) ZQ05B10 ZQ07B10.
—2— CONTENTS 1. PREF A CE ...................................................................................................................................................3 1.1 FEA TURES...........................................................
—3— 1. PREF A CE This ser vice manual provides v arious ser vice inf or mation, including the mechanical and electr ical par ts, etc. This room air conditioner was manuf actured and assembled under a strict quality control system. The refrigerant is charged at the f actory .
—4— 1.3 LOCA TIONS OF CONTROLS 1.4 SAFETY PRECA UTIONS 1. When ser vicing, set the RO T AR Y SWITCH to Off and unplug the power cord. 2. Obser ve the original lead dress. If a shor t circuit is found, replace all parts which hav e been ov erheated or damaged by the short cir- cuit.
— 5 — 2. DISASSEMBL Y INSTR UCTIONS 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Disconnect the unit from source of power . 2. Remov e the two knobs by pulling them off . Using a screwdriv er , remov e the screw that secures the front grille to control board.
— 6 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the pow er source . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e the control panel . (Ref er to Section 2.
— 7 — 2.2.3 MO T OR 1. Disconnect the unit from the pow er source . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e the control panel . (Ref er to Section 2.1.3) 5. Remov e the air guide upper .
— 8 — 2.3.2 COMPRESSOR 1. Remov e the front grille and cabinet. (Ref er to Section 2.1) 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the overload protector . (Ref er to Section 2.3.1) 4. After discharging the unit completel y , unb r a z e the suction and discharge pipes at the compressor connections.
— 9 — 2.3.6 PO WER CORD 1. Disconnect the unit from source of power . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Rem o v e a scr e w that secures control panel to base pan. (Ref er to Section 2.
2.4.2 E V APOR A T OR /CONDENS E R 1. Remov e the cabinet. 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the air guide upper . (Refer to Section 2.2.1) 4. After discharging the refrigerant completely , unb r a z e the interconnecting tube at the proper connections.
— 11 — Equipment needed: V acuum pump, charging cylinder , manifold gauge , brazing equipment, pinch-off tool capable of making a v apor proof seal, leak detector , tubing cutter , hand tools to remove components and service valv e.
— 1 2 — 3 . T R OUBLESHO O TING GUIDE 3 .1 OUTSIDE DIMENSIONS (unit: mm [in]) 370 (14 9 / 16 ") 312 (12 1/4 ") 370 (14 9 / 16 ") 312 (12 1/4 ") 29 (1 5 / 32 ") 120 (4 3 / 4 ") 27.5 (1 3 / 32 ") 346 (13 5 / 8 ") 472 (18 9/16 ") 42 (1 21 / 32 ") 42 (1 21 / 32 ") 155(6 3/32 ") 12 (0.
— 1 3 — 3 .2 PIPING SYSTEM Figure 2 2 is a b r ief desc r iption of the impo r tant components and their function in what is called the ref r ige r ation system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
— 1 4 — 3 .3 T R OUBLESHO O TING GUIDE In gene r al, possi b le trou b le is classified in t w o categories . The one is called Starting Failure which is caused by an electrical def ect. The other is Ineffective Air Con- ditioning caused b y a de f ect in the ref r ige r ation circuit and /or improper application.
— 1 5 — Fails to Start Improper thermostat setting Loose ter minal connection Improper wiring Che c k p o w er sourc e . Drop of pow er voltage . Capacitor check. Replacement. Che c k control s witch setting. Compressor f ails to star t. Def ect of compressor capacitor .
— 1 6 — ROOM AIR CONDITIONER V OL T A GE LIMITS NAME PLA TE RA TING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V COMPLAINT CA USE REMED Y F an motor will not run. No pow er Check v oltage at outlet. Correct if none. P ower supply cord Check v oltage to rotar y switch.
— 17 — COMPLAINT CA USE REMED Y F an motor noise. F an If crac ked, out of balance , or par tially missing, replace it. Blow er If crac ked, out of balance , or par tially missing, replace it. Loose set screw Tighten it. W orn bear ings If knocking sounds contin ue when running or loose, replace the motor .
— 18 — COMPLAINT CA USE REMED Y Compressor cycles on F an motor If not running, deter mine the cause. Replace if ov er load. required. Condenser air flow Remo ve the cabinet, inspect the interior surf ace restriction of the condenser . If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush.
— 19 — 4 . CIRCUIT DI A GRAM 1 2 6 7 5 3854AR2330A COMP. MOTOR ROCKER SWITCH YL BR THERMOSTAT OLP BR R BL RD BK OR(BR) CAPACITOR F H C YL ROTARY SWITCH 2H L M BK BR RD BL BK POWER INPUT BK(BR) (Plain) WH(BL) (Ribbed) GN(GN/YL) RD BL YL OR(BR) 4 6 8 1 3 5 7 BL RD BK BR WIRING DIAGRAM SYNC.
— 2 0 — 5 . EXPLODED VIEW 152302 149410 147581 147582-2 147582-1 135313 352390 135312 130410 359012 W48602 354210 349480 352380 149980 559011 346811 554030 W48602 130910 266003 264110 269310 W0CZZ.
—2 1 — 6 . SE R VICE P A R TS LIST • ZQ05 B 10 . ZQ07B10 Loc No FRIEDRICH Description 130410 67302921 BASE ASSEMBLY,WELD[SINGLE] 130910 67303709 CABINET ASSEMBLY,SINGLE 135312 67306003 GRILLE AS.
Loc No FRIEDRICH Description 130410 67302921 BASE ASSEMBLY,WELD[SINGLE] 130910 67303709 CABINET ASSEMBLY,SINGLE 135312 67306003 GRILLE ASSEMBLY,FRONT(SINGLE) 135313 67306103 GRILLE,INLET 135500 673003.
— 2 3 — MEMO.
Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Friedrich ZQ07B10 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Friedrich ZQ07B10 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Friedrich ZQ07B10, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Friedrich ZQ07B10 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Friedrich ZQ07B10, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Friedrich ZQ07B10.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Friedrich ZQ07B10. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Friedrich ZQ07B10 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.