SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED t y p e C O N T E N T S SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . 1 DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . 2 REFRIGERANT SYSTEM DIAGRAM . . . . 4 CIRCUIT DIAGRAM . . . . . . .
S P E C I F I C A T I O N S INDOOR UNIT MW30C3F MW36C3F OUTDOOR UNIT MR30C3F MR36C3F COOLING CAPACITY 30,700 BTU/hr 33,100 BTU/hr POWER SOURCE 208 V / 230 V 208 V / 230 V FREQUENCY 60 Hz 60 Hz RUNNING CURRENT 15.2 A 17.7 A MAXIMUM CURRENT . A . A INPUT WATTS 3,460 W 4,040 W SEER 15.
O U T L I N E A N D D I M E N S I O N S Unit : inch (mm) INDOOR UNIT 39-1/4" (998) 9" (228) 12-5/8" (320) 2008.01.09 2.
Unit : inch (mm) OUTDOOR UNIT 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2" (12) 7-3/4" (196) 5-3/4" (147) 6-3/4" (170) 3-7/8" (99) 14-5/8" (370) 25-5/8" (650) Air Flow 2008.
R E F R I G E R A N T S Y S T E M D I A G R A M 3-Way valve (Small) 3-Way valve (Large) Strainer Strainer Muffler Pressure switch 4-Way valve Expansion valve Heat exchanger (indoor unit) Heat exchanger (outdoor unit) Sub-accumulator Compressor Refrigerant direction Refrigerant pipe diameter Liquid : 3/8" (9.
RED RED BLACK WHITE YELLOW BLUE RED BROWN BLUE ORANGE YELLOW WHITE BLACK BLACK BROWN BROWN BLACK BLACK BLUE BLUE BROWN BROWN RED RED GREEN BLACK WHITE WHITE BLACK BLACK WHITE BLACK WHITE WHITE WHITE W.
CN1 1 B07B-P ASK-1 CN201 JB20-07HG CN1 1-1 RED CN1 1-2 WHITE CN1 1-3 WHITE CN1 1-4 WHITE CN1 1-6 WHITE CN1 1-7 WHITE CN1 1-5 WHITE 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 6 6 5 4 3.
5V C54 0.01 <B> R114 390 <1/10W> D14 DAN202K Q11 RT1N241M 1 10 2 3 4 5 14 18 Q10 RT1N241M 12V 12V 12V 12V I C16 I C18 I C7 R109 10K <1/10W> BZ1 PKM13EPYH-4000-A0 I C18-7 uLN2003ADR 5V L3 0R0 R101 330 <1/10W> L4 0R0 I C25 R88 1.
CN201 07 JB20 / P AP 1061 L=230 5V C201 0.1 <F> 5V + C202 47/ 10V R201 47 <1/4W> I C201 GP1UM261RKVF 5V D201 SLR-325VC D203 SLR-325DC D202 SLR-325MC 5 4 6 1 2 3 7 2 1 3 VCC OUT GND RED GREEN ORANGE INDOOR UNIT INDICA TOR PCB ASSEMBL Y K05CY -0500HSE-D0 2008.
UL1015 AWG14 WHITE UL1015 AWG14 BLACK UL1015 AWG20 WHITE UL1015 AWG20 RED UL1015 AWG20 BLACK POWER SOURCE AC208 - 230V 60Hz INDOOR UNIT N L 3 2 1 EMI FILTER W17 B W18 B W2 B W1 B W3 B EARTH UL1015 AWG.
R648 4.75K <1/10W> 1% R649 0R0 <1/10W> C643 0.01 <F> C645 0.1 <F> C644 0.01 <F> - + 7 5 6 + 1 2 3 - 15V 5V 5V R644 1.0K <1/10W> R650 1.0K <1/10W> C640 0.01 <F> JM600 0R0 I C640-1 BA2903F I C640-2 BA2903F 5V R651 10K <1/10W> C641 0.
1 2 3 4 5 6 7 8 9 10 12 13 11 14 15 16 17 18 19 20 21 22 23 24 25 26 UP VP I VUFB VUFS VP VP I VVFB VVFS WP VP I VPC VWFB VWFS VNC VN I C I N CFO FO UN VN WN P U V W N I C 301 PS21267-AP 15V C332 0.1 <F> C302 47/ 35V + D307 HZ24BP-TK-E L300 BL02Rn1 R304 1.
12V K101 DW12D1-O(M) 3 2 4 1 C108 3.3 <LE> L102 N200500K1D7C 12V B B B B CN100 UL1007 AWG26 2P POWER RELA Y CONTROL W29 BROWN W28 ORANGE W26 ORANGE W25 ORANGE PTC OUT C106 3.3 <LE> L101 RCH3818 - 022PF07 4 3 1 2 CT OUT W21 GRAY B W9 BLACK L100 RCH3818 - 022PF07 C103 3.
.
4 2 2 4 6 1 5 5 2008.01.09 14 P A R T S INDOOR UNIT 1 Front Panel Total Assy 9315335081 2 Intake Grille Assy 9315336064 4 Air Filter 9315014016 5 Clamper (Grille) 9306755010 6 Receiver Window 9315010018 Ref.
2008.01.09 15 INDOOR UNIT Evaporator 8 31 35 36 34 29 30 27 25 28 32 33 9 8 Crossflow Fan Assy 9315024015 9 Bearing C Assy 9306628017 27 Evaporator Assy A 9315348012 28 Evaporator Assy B 9315349019 25.
26 23 22 2008.01.09 16 INDOOR UNIT Casing assy 10 13 14 1 1 12 15 16 17 18 19 20 21 Ref. Description Part number 10 Casing Assy 9315331021 22 R and L Louver 9311997016 23 Spacer B 9312441013 26 Drain .
INDOOR UNIT 17 2008.01.09 46 48 52 55 40 42 41 53 39 37 38 47 57 56 Ref. Description Part number 37 Controller PCB Assy (30) 37 Controller PCB Assy (36) 9707090093 9707090109 38 Control Box 9314996023.
OUTDOOR UNIT 2008.01.09 18 6 7 5 2 4 3 1 Ref. 1 Top Panel Sub Assy 9374417032 2 Front Panel 9374094066 3 Fan Guard 9374330010 4 Grip Side 9374173013 5 Service Panel Sub Assy 9374415052 6 Right Panel 9.
OUTDOOR UNIT 2008.01.09 19 9 8 10 13 15 8 Propeller Fan Assy 9366378020 9 Fan Motor 9602114016 10 Condenser A Assy 9374433148 13 Separate Wall 9374413133 15 Base Assy 9374166138 Ref.
OUTDOOR UNIT 2008.01.09 20 24 21 27 25 12 28 17 18 26 20 19 29 23 22 Ref. 12 Strainer Assy 9372524015 17 3-Way Valve Assy 9372205044 18 3-Way Valve Assy 9372205075 19 Check Joint Assy 9372802038 20 Co.
OUTDOOR UNIT 2008.01.09 21 46 47 48 41 39 36 38 42 37 45 35 33 40 31 CONNECTOR : BLUE CONNECTOR : ORANGE DISCHARGE TEMP THERMISTOR OUTDOOR TEMP THERMISTOR CONNECTOR : GREEN COMPRESSOR TEMP THERMISTOR CONNECTOR : RED HEA T EXCHANGER THERMISTOR CONNECTOR : RED PRESSURE SWITCH WIRE Ref.
9305642045 Remote control holder Name and Shape Part number 9315023018 9315027160 0600185534 0700076046 9310519004 Remote control Battery (penlight) Cloth tape Tapping screw (big) Wall hook bracket S T A N D A R D A C C E S S O R I E S Tapping screw (small) 0700019036 2008.
0602G3030.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Friedrich MW36C3F c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Friedrich MW36C3F - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Friedrich MW36C3F, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Friedrich MW36C3F va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Friedrich MW36C3F, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Friedrich MW36C3F.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Friedrich MW36C3F. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Friedrich MW36C3F ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.