SPECIFICA TIONS TYPE INDOOR UNIT OUTDOOR UNIT COOLING CAP ACITY PO WER SOURCE FREQUENCY RUNNING CURRENT (Heat) INPUT W A TTS (Heat) E.E.R. (Heat) MOISTURE REMO V AL AIR CIRCULA TION-High ELECTRICAL DA.
OUTLINE AND DIMENSIONS INDOOR UNIT Unit : inch (mm) 39-1/8" (990) 19-3/4" (500) 4-23/32" (120) 35" (900) 25-7/8" (655) 20-7/8" (530) 7-27/32" (199) 2-3/4" (70) 7-7/8" (200) 6-7/8" (175) 7-7/8" (199) (rear view) 2 2006.
Unit : inch (mm) OUTDOOR UNIT 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2" (12) 7-3/4" (196) 5-3/4" (147) 6-3/4" (170) 3-7/8" (99) 14-5/8" (370) 25-5/8" (650) Air Flow 3 2006.
REFRIGERANT SYSTEM DIAGRAM : COOL : HEAT Evaporator OUTDOOR UNIT Pressure Check Valve Condenser 4-way Valve High Pressure Switch Accumulator Muffler Compressor Expansion Valve Refrigerant Pipe 9.52mm (3/8") Charging Valve Charging Valve Refrigerant Pipe 15.
CIRCUIT DIAGRAM INDOOR UNIT TERMINAL STEP MO T OR ( LEFT / RIGHT ) STEP MO T OR (U P/D O W N) F A N M OTO R CAP A CITOR F A N M OTO R ROOM TEMPERA TURE THERMIST OR PIPE TEMPERA TURE THERMISTOR FM M M 1 2 31 2 3 Use T3.
OUTDOOR UNIT ORANGE YELLOW WHITE BLUE BRO WN RED BLUE YELLOW WHITE BLACK RED BLACK BLACK RED RED BLACK BRO WN BLUE BRO WN BLACK RED BRO WN BLACK BLACK WHITE BLACK BLACK WHITE WHITE GREEN BLACK WHITE B.
CONTROLLER PCB ASSY K01AL-050SHSE-C1 INDOOR PCB CIRCUIT DIAGRAM 7 2006.05.25.
POWER SUPPL Y PCB ASSY K04BA-0500HUE-P0 CONTROLLER PCB ASSY K04A W-0502HUE-C1 INVERTER ASSEMBL Y EZ-005FHUE OUTDOOR PCB CIRCUIT DIAGRAM 8 2006.05.25.
600/450V x 4 OUTDOOR UNIT CONTROLLER PCB ASSEMBL Y K04A W-0502HUE-C1 9 2006.05.25.
5V TM101 TM102 C1 12 0.015 <YE> C1 13 0.015 <YE> C1 1 1 3.3 <LE> L4 RCH4730-021PF07 C107 3.3 <LE> TM100 L2 N200500K1D7C CT1 CT -1B 5V D60 DAN217U C64 0.1 <F> R68 22K <1/10W> C65 0.1 <F> VR1 B2K + R61 3.74K <1/10W> (1%) C60 220/16V <PJ> R60 1.
ERROR CONTENTS (Indoor unit) Operation can be checked by lighting and flashing of the display section OPERATION, , and TIMER lamps. Perform judgment in accordance with the following.
ERROR CONTENTS (outdoor unit) 1. Make a TEST RUN in accordance with the in- stallation instruction sheet for the indoor unit. 2. OUTDOOR UNIT LEDS Error contents Communication error (Indoor unit - Out.
DISASSEMBLY ASSEMBLY INDOOR UNIT 13 2006.05.25 653-2 365-1 365-2 365-2 365-1 870-1 653-2 870-1 509 173 580 508 174 240 743.
14 2006.05.25 INDOOR UNIT 196-1 184-1 470 764 577 127 124 235 124 108 68 578 418 160 439 138 68 187.
15 2006.05.25 983 983 INDOOR UNIT.
416 417 385 771 488 472 473 443 8-1 16 2006.05.25 INDOOR UNIT.
17 2006.05.29 800 652-1 735 146 OPTIONAL P AR TS INDOOR UNIT.
18 2006.06.13 INDOOR UNIT 982.
684 558 555 554 520 521 505 505 505 321 320 361 69 69 69 69 502 505 506 500 407 408 503 876-2 876-1 361-2 361-2 361-2 361-3 361-3 361-3 361-2 19 2006.05.
1 6 3 4 5 2 20 2006.05.29 OUTDOOR UNIT.
17 18 10 13 11 9 15 14 8 OUTDOOR UNIT 2006.06.13 21.
22 23 31 20 29 12 28 12 19 24 26 27 25 30 22 2006.05.29 OUTDOOR UNIT.
37 38 33 34 36 35 23 2006.05.29 OUTDOOR UNIT.
PARTS LIST INDOOR UNIT Ref. Part No. Ord. Ref. Part No. Ord. No MS24Y3F Q'ty No MS24Y3F Q'ty 8-1 Air Filter 67220192 500 Protect Cover 67220242 34 Capacitor (Fan Motor) 67220218 502 SupportS.
OUTDOOR UNIT Ref. Part No. Ord. No MR24UY3F Q'ty 1 Top Panel Sub Assy 67201640 2 Front Panel 67201601 3 Fan Guard 67201602 4 Grip Side 67201603 5 Service Panel Sub Assy 67201688 6 Right Panel 672.
1 1 2 1 1 1 4 4 1 1 4 2 6 1 1 1 1 Q'ty INDOOR UNIT ACCESSORIES Name and Shape Part No. Application For positioning the indoor unit. For under ceiling type. For suspending the indoor unit from ceiling. For suspending the indoor unit on the wall. For fixing the wall bracket.
1 1 2 2 For remote control unit holder installation Use for air conditioner operation (AR-JW5) For remote control unit Use are remote control unit holder 9371190051 0600185534 9305642014 0700019098 Remote control unit holder Tapping screw Remote control unit Battery (penlight) Q'ty REMOTE CONTROL UNIT Name and Shape Part No.
0605G3090.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Friedrich MS24Y3F c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Friedrich MS24Y3F - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Friedrich MS24Y3F, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Friedrich MS24Y3F va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Friedrich MS24Y3F, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Friedrich MS24Y3F.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Friedrich MS24Y3F. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Friedrich MS24Y3F ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.