SPLIT TYPE AIR CONDITIONER (60Hz) CASSETTE type Models Indoor unit Outdoor unit MC24Y3F MR24UY3F CONTENTS SPECIFICATIONS ...................... 1 DIMENSIONS .......................... 2 REFRIGERANT SYSTEM DIAGRAM ....... 4 CIRCUIT DIAGRAM ............
INDOOR UNIT HxWxD DIMENSIONS INDOOR UNIT Gross / Net Gross / Net OUTDOOR UNIT WEIGHT POWER SOURCE COOLING RUNNING CURRENT HEATING INPUT WATTS COOLING HEATING E.
INDOOR UNIT unit : inch (mm) DIMENSIONS 2006.05.18 2 9-3/4" (246) 9-1/4" (235) 9-25/32" (248.5) 11-3/4" (298.5) 12" (305.5) 1-3/16" (30) 37" (940) 37" (940) 2-3/8" (60) Drain inside Dia. ø1-1/4" (ø32) outside Dia.
OUTDOOR UNIT unit : inch (mm) 2006.05.18 3 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2".
Evaporator OUTDOOR UNIT Pressure Check Valve Condenser 4-way Valve High Pressure Switch Accumulator Muffler Compressor Expansion Valve Refrigerant Pipe 9.52mm (3/8") Charging Valve Charging Valve Refrigerant Pipe 15.88mm (5/8") INDOOR UNIT Strainer Strainer REFRIGERANT SYSTEM DIAGRAM : COOL : HEAT 2006.
CIRCUIT DIAGRAM INDOOR UNIT 2006.05.18 5 YELLOW YELLOW BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK PURPLE BLUE RED WHITE WHITE RED RED WHITE WHITE WHITE GREEN / YELLOW WHITE WHITE YELLOW YEL.
OUTDOOR UNIT 2006.05.18 6 ORANGE YELLOW WHITE BLUE BRO WN RED BLUE YELLOW WHITE BLACK RED BLACK BLACK RED RED BLACK BRO WN BLUE BRO WN BLACK RED BRO WN BLACK BLACK WHITE BLACK BLACK WHITE WHITE GREEN .
Model : MC24Y3F CONTROLLER PCB ASSEMBL Y K01AL-050LHSE-C1 2006.05.25 7 INDOOR PCB CIRCUIT DIAGRAM.
Model : MR24UY3F POWER SUPPL Y PCB ASSY K04BA-0500HUE-P0 CONTROLLER PCB ASSY K04A W-0502HUE-C1 INVERTER ASSEMBL Y EZ-005FHUE 2006.05.25 8 OUTDOOR PCB CIRCUIT DIAGRAM.
600/450V x 4 2006.05.25 9 CONTROLLER PCB ASSEMBL Y K04A W-0502HUE-C1 Model : MR24UY3F.
5V TM101 TM102 C1 12 0.015 <YE> C1 13 0.015 <YE> C1 1 1 3.3 <LE> L4 RCH4730-021PF07 C107 3.3 <LE> TM100 L2 N200500K1D7C CT1 CT -1B 5V D60 DAN217U C64 0.1 <F> R68 22K <1/10W> C65 0.1 <F> VR1 B2K + R61 3.74K <1/10W> (1%) C60 220/16V <PJ> R60 1.
ERROR CONTENTS (indoor unit) SU MO TU WE TH FR SA (1) Stop the air conditioner operation. (2) Press the master control button and the fan control button simultane- ously for 2 seconds or more to start the test run. Unit number (usually 0) Error code (3) Press the start/stop button to stop the test run.
ERROR CONTENTS (outdoor unit) 1. Make a TEST RUN in accordance with the in- stallation instruction sheet for the indoor unit. 2. OUTDOOR UNIT LEDS Error contents Communication error (Indoor unit - Out.
692 544 710 469 468 858 487 71 71 858 61 240 93 545 481 481 481 544 705 847 542 705 847 692 690 692 847 543 543 544 544 122 543 122 847 692 690 692 847 543 847 122 690 847 692 226 338 522 122 122 834-2 876-2 472-4 253-A 472-2 481-1 472-3 777-2 777-1 472-1 472-5 472-5 472-5 472-5 DISASSEMBLY ILLUSTRATION INDOOR UNIT 2006.
479 467 127 835 482 798 835 484 465 244 563 814 484 484 464 462 164 484 168 474 477 223 457 488 160 457 514 803 187 460-1 834-1 476-2 460-2 197 197 565 337-1 146-2 146-1 337-1 337-2 INDOOR UNIT 541 334 541-1 815-1 2006.
INDOOR UNIT 236 380 380 380 195 625 234 212 875 34 32 815-2 320-1 320-1 381-4 731-2 381-4 2006.05.18 15.
INDOOR UNIT 138 735 184-1 235 896 2006.05.18 16 187.
OUTDOOR UNIT 1 6 3 4 5 2 2006.05.25 17.
17 18 10 13 11 9 15 14 8 OUTDOOR UNIT 2006.05.25 18.
22 23 31 20 29 12 28 12 19 24 26 27 25 30 OUTDOOR UNIT 2006.05.24 19.
37 38 33 34 36 35 OUTDOOR UNIT 2006.05.18 20.
PARTS LIST INDOOR UNIT Ref. Part No. Ord. Ref. Part No. Ord. No MC24Y3F Q'ty No MC24Y3F Q'ty 32 Control Box Assy 67200589 472-3 RFM (Grille)-C 67200562 34 Capacitor (Fan Motor) 67220259 472-.
OUTDOOR UNIT Ref. Part No. Ord. No MR24UY3F Q'ty 1 Top Panel Sub Assy 67201640 2 Front Panel 67201601 3 Fan Guard 67201602 4 Grip Side 67201603 5 Service Panel Sub Assy 67201688 6 Right Panel 672.
INDOOR UNIT ACCESSORIES OUTDOOR UNIT ACCESSORIES Q’ty 2 2 4 4 1 1 2 2 1 1 Name and Shape Coupler heat insulation Tapping Screw (flush heads) Special nut A (large flange) Special nut B (small flange).
0605G3089.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Friedrich MC24Y3F c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Friedrich MC24Y3F - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Friedrich MC24Y3F, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Friedrich MC24Y3F va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Friedrich MC24Y3F, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Friedrich MC24Y3F.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Friedrich MC24Y3F. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Friedrich MC24Y3F ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.