SH15L30-B SH20L30-B HG-SVC-PRTS-07 (3-07) R oom Air Conditioners 60 Hz Mode ls 20 0 7 Ser vi ce & P ar ts Manu al.
2 T ABLE OF CONT EN TS Speci fi cations ...................................................................................................................... ................................... 3 Per formance Data ...................................
3 EV APORA T OR AIR TEMP . DEG. F EV APORA TOR TEMP . DEG. F CONDENSER TEMP . DEG. F Discharge T emp Suction T emp Liquid T emp Super Heat Sub- Cooling OPERA TING PRESSURES ELECTRICAL RA TINGS R-22 REF . Evap CFM Motor RPM BREAKER FUSE Discharge Air T emp.
4 COMPRESSOR WINDING TEST (Figure 2.) Remov e the c ompress or terminal box c over and disconnect the wires from t he terminals. Using an ohmmeter , c heck c ontinuit y across the follow ing: COMPONENT OPERA TION AND TESTING COM PRE SSO RS Compress ors are single phase, 208 /23 0 volt.
5 F AN MOTOR (Figure 4) A 230 volt single phase per manent split capacitor m otor is used to drive the evaporator blower and condenser fan. A running c apacitor is wired acros s the star t and r un terminals of the motor . The motor is totally enc losed and is protected with a line volt- age overload located inter nally of the motor .
6 THERMOST A T A cross ambient ther most at is used to maintain the desire d comfor t level . The ther most at reacts only to a change in temperature at the bulb location. Impor t ant to the succ essful operation of the unit is the posit ion of the sensing bulb in relation to the evaporator ( see Figure 8 ) .
7 NOTE: This procedure can be sped up by the use of heat lamps, or by breaking the v acuum with refr igerant o r d r y n i t r o g e n a t 5 , 0 0 0 m i c r o n s . P r e s s u r e s y s t e m t o 5 PSIG and leave in the s ystem a minimum of 10 minutes.
8 TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE TO CORRECT UNIT DO ES NOT RUN. Power disconnected. Check power source. System switch in “ O f f ” posit ion. Set switc h co rrec tly . Branch circuit f use blown or circuit breaker tripped. Replace fuse, reset breaker .
9 TROUBL ESHOOTING ( Continu ed) PROBLEM POSSIBLE CAUSE TO CORRECT COM PRES SOR AT T E M P T S T O ST ART , OR RUNS FO R S H O R T PERIOD S ON L Y . CYCL ES O N OV ER LOA D. Compress or attempts to st ar t before syst em pressures are equal ized. Allow a minimum of t wo (2 ) minutes to allow pres sures to equalize before attempting to star t.
10 TROUBL ESHOOTING ( Continu ed) PROBLEM POSSIBLE CAUSE TO CORRECT F AN M OTOR DOES NOT R U N. Defective switch (On- Of f ). Check co ntinuit y across ter minals 2 and 3. F an capacitor open. Check by substituting a known go od c apacitor of the s ame rating .
11 WIRING DIA GR AM MODELS SH 1 5L30 - B and SH20L30 - B.
12 HAZARDGARD CABINET P ARTS.
13 HAZARDGARD CHASSIS P ARTS.
14 HAZARDGARD P ARTS LIST REF DESCRIPTION P ART NO# MODELS CODE ELECTRICAL P ARTS SH15L30-B SH20L30-B 1 COMPRESSOR 61 193549 1 600 1 COMPRESSOR 61 193550 1 600 2 MOTOR, F AN 61871426 11 1 0 2 MOTOR, F.
15 HAZARDGARD P ARTS LIST REF DESCRIPTION P ART NO# MODELS CODE CHASSIS P ARTS SH15L30-B SH20L30-B 8 HOLDER, THERMOST A T 61829800 1 1 999 1 1 KNOB, CONTROL 61493915 1 1 761 17 DECORA TIVE P ANEL 61822662 1 1 760 22 F AN BLADE, COND. 60542003 1 710 22 F AN BLADE, COND.
HG-SVC-PRTS-07 (3-07) FRIEDRICH AIR CONDITIONING CO. Post Of fi ce Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4480 www .friedrich.com Printed in the U.S.A. Friedrich Air Conditioning Company P.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Friedrich HazardGard 60 Hz c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Friedrich HazardGard 60 Hz - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Friedrich HazardGard 60 Hz, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Friedrich HazardGard 60 Hz va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Friedrich HazardGard 60 Hz, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Friedrich HazardGard 60 Hz.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Friedrich HazardGard 60 Hz. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Friedrich HazardGard 60 Hz ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.