IAQ GUIDE 1 1 HEALTHY HOME SYSTEM ™.
2 FRESH CLEAN P U R E FRESH CLEAN P U R E Field Controls has developed the premier system that simply and inexpensively transforms the heating and cooling system in any home into a Healthy Home System. The Healthy Home System goes beyond traditional technology to ensure air that is Fresh, Clean, and Pure.
FRESH CLEAN P U R E fieldcontrols.com 3 FRESH CLEAN P U R E Healthy Home System™ Control Media Air Cleaner™ UV -Aire ® Air from all rooms RETURN T o all rooms FRESH, CLEAN , PURE AIR Fresh Air Damper For installation options (including upflow, horizontal, downflow, and heat pumps/gas packs) turn to page 5.
4 FRESH CLEAN P U R E FRESH CLEAN P U R E FRESH Fresh Air Ventilation CLEAN Media Air Cleaners PURE UV-Aire ® Purification For the Home • Creates uniform temperature and humidity throughout the home • Helps meet residential ventilation standard ASHRAE 62.
FRESH CLEAN P U R E fieldcontrols.com 5 FRESH CLEAN P U R E INSTALLATION OPTIONS HORIZONT AL UPFL OW DOWNFL OW EXTERNAL HEA T PUMP or GAS P ACK UV -Aire ® Air Purifier Fresh Air Damper RETURN Media A.
6 FRESH FRESH CONTROL The heart and brains of the Healthy Home System The Healthy Home System Control intelligently manages the central fan to maximize the benefits of the Healthy Home System. It’s the easiest, most cost effective way to ensure the air in the home is FRESH , CLEAN, and PURE .
FRESH fieldcontrols.com 7 FRESH • Delivers fresh air automatically, year round • Enables system to meet ASHRAE 62.2 ventilation standard for fresh air • Creates uniform temperature and humidity .
8 CLEAN CLEAN The Media Air Cleaner is a whole house air filtration system that combines minimum maintenance with maximum air cleaning capacity. As part of the Healthy Home System, the media air cleaner works with the Healthy Home System Control to CLEAN the air in the home all year round.
CLEAN fieldcontrols.com 9 CLEAN Dimensions Cabinet A B C Duct Opening D E 1400 7 1 ⁄ 8 " 24 7 ⁄ 8 " 16 1 ⁄ 4 " 22 1 ⁄ 2 " 13 7 ⁄ 8 " 2000 7 1 ⁄ 8 " 24 7 ⁄ 8.
10 PURE PURE Field Con trols of f ers a c omple te line of U V - A ire p roduc t s for any home or busine ss, wit h a variet y of duc t-mo unte d mode ls design ed for fo rced- air hea ting and cooling s ys te ms.
PURE fieldcontrols.com 11 PURE Optional Installation Location Best Installation Location (down-stream of the A-coil) H A-Coil Installing UV-Aire near the coil helps maintain optimal efficiency of the VAC system.
12 PORTABLES Portable air purification The portable UV-Aire models combine the purifying power of UV with high efficiency and carbon filtration to reduce dust, pollen, odors and VOCs. The UV-Aire portables are recommended for anyone with allergies, a respiratory illness, or a compromised immune system.
fieldcontrols.com 13 The Smart Switch for Smart Houses The easiest, most cost efficient way to help make a home ASHRAE 62.2 compliant. The SmartExhaust turns the bathroom fan into an automatic exhaust system that helps eliminate stale air from the home.
14 UV-Aire ® Air Purification Lamps Model Ref. No. Description Part No. UV-12, UV-1500C C Lamp 12" 46365401 UV-16/120, UV-16/24 C Lamp 16" 46511200 UV-18 C Lamp 18" 46365402 UV-28 C Lamp 28" 46365403 UV-500C C Lamp 8" 46508000 Portable UV-Aire ® Annual Replacement Kits Model Ref.
fieldcontrols.com 15 PURE U V- A i r e ® I n - D u c t M o d e l s M o d e l M i n i m u m D u c t W i d t h ( I n c h e s) Vo l t a g e A m p s Wa t t s R e c o m m e n d e d M a x . S q . F t . U V -12 9 120 0.5 30 1500 U V -18 14 120 0.5 30 2000 U V -2 8 22 120 1.
fieldcontrols.com ©2011 Field Controls Form # 4342 Printed in U.S.A.(TD11) Fi el d C on tr ols , L LC 2630 Airport Road Kinston, NC 28504 T: 252.522.3031 F: 252.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Field Controls IAQ11 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Field Controls IAQ11 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Field Controls IAQ11, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Field Controls IAQ11 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Field Controls IAQ11, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Field Controls IAQ11.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Field Controls IAQ11. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Field Controls IAQ11 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.