Manuel d'utilisation / d'entretien du produit RCP 2000 du fabricant Extron electronic
Aller à la page of 23
User ’ s Manual © 2005 Extron Electronics. All rights reserved. Extron Electronics, USA 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Extron Electronics, E urope Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.
Precautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock.
RCP 2000 • Quick Start Guide Step 1 T urn the equipment of f and disconnect it from the power sour ce. Make sure that the ISS 108/408 or SGS 408 and all attached devices are turned of f and, if applicable, disconnected from the power sour ce. Step 2 Set the RCP 2000 on a table or other flat surface.
RCP 2000 • Quick Start Guide Quick Start Guide — RCP 2000, cont’d iii RCP 2000 • Table of Contents Chapter 1 • Introduction .......................................................... 1-1 Features .............................................
iv RCP 2000 • Table of Contents T able of Contents, cont’d RCP 2000 Remote Control Panel Accessing and using the Web pages .................................... 4-4 Logon and system status ................................................. 4-4 Establishing or changing system settings .
RCP 2000 • Introduction Introduction, cont’d RCP 2000 Remote Control Panel 2 Chapter T wo Installation Rear Panel Connectors Installation Application Example Making an RCP Communication Cable Introduction The Extron RCP 2000 r emote control panel provides complete remote control of a seamless switcher .
RCP 2000 • Installation Installation, cont’d RCP 2000 • Installation Rear Panel Connectors ETHERNET LINK 120-240VA C 50/60 Hz 1.2A MAX. TO S WITCHER ACT R S -2 3 2 RE S ET 1 4 3 2 5 Figure 2-1 — RCP 2000 rear panel 1 AC power connector — Plug a standard IEC power cor d from a 100 to 240 V AC, 50/60 Hz power source into this connector .
RCP 2000 • Installation Installation, cont’d RCP 2000 • Installation 2-4 Application Example The following diagram is an example of the RCP 2000 connected to an ISS 408, along with various input and output devices.
RCP 2000 • Installation Installation, cont’d RCP 2000 Remote Control Panel 3 2-6 Chapter Thr ee Operation Top Panel Controls Using the Picture Controls Applying and Changing a Switching Effect Res.
RCP 2000 • Operation Operation, cont’d RCP 2000 • Operation Operation 3-2 T op Panel Controls FREEZE BLACK 1 2 3 4 5 6 7 8 9 10 11 12 CONT BRIGHT H DIMMER V COLOR TINT WIPE DISOL VE TAK E FREEZE.
RCP 2000 • Operation Operation, cont’d RCP 2000 • Operation 3-4 W ipe button (SGS only) — Causes the preview image to appear to unroll over the program image horizontally or vertically . The different wipe effects include standard, curtain, plus, square, and title window .
RCP 2000 • Operation Operation, cont’d RCP 2000 • Operation Detail adjustments T o apply a horizontal or vertical filter to improve the sharpness of an image, do the following: 1 . Pr ess and release the Detail button. The button lights. 2 . V arious levels of detail adjustment are available, depending on the input signal format.
RCP 2000 • Operation Operation, cont’d RCP 2000 • Operation Curtain wipe A curtain wipe causes the preview image to appear to unroll over the program image in two directions simultaneously . A curtain wipe can have either har d (sharp) or soft (fuzzy) edges.
RCP 2000 • Operation Operation, cont’d RCP 2000 • Operation 3-10 SOFTWIPE L T to RT SOFTWIPE RT to L T SOFTWIPE TP to BM SOFTWIPE BM to TP S CURT HRZ IN S CURT HRZ OUT S CURT VERT IN S CURT VERT.
RCP 2000 • Operation Operation, cont’d RCP 2000 Remote Control Panel 4 Chapter Four Remote Contr o l Manual IP Setup Network IP Setup and Control Network Switcher Control 3-12 Mode 3 — Pressing .
RCP 2000 • Remote Control Remote Control, cont’d RCP 2000 • Remote Control 4-2 4-3 Manual IP Setup The RCP 2000 unit ships with default server (ISS) and client (RCP) IP addresses, as well as Subnet Mask and Gateway Address, already set.
RCP 2000 • Remote Control Remote Control, cont’d RCP 2000 • Operation 4-4 4-5 Network IP Setup and Control Once the IP addresses have been changed, if r equired, you can contact and control the RCP 2000 by using W eb pages that are resident, in firmwar e, on the RCP unit.
RCP 2000 • Remote Control Remote Control, cont’d RCP 2000 • Remote Control Figure 4-4 — System Settings screen 2 . Make changes to the IP Settings, Date/T ime settings, etc., as necessary . 3 . Click the Submit button to enter the changes, or click the Cancel button to revert to the previous settings.
RCP 2000 • Remote Control Remote Control, cont’d RCP 2000 • Remote Control 4-8 4-9 File management The File Management screen is used to upload new files (for custom or updated W eb pages) to the RCP unit and to delete existing files from the unit.
RCP 2000 • Remote Control Remote Control, cont’d RCP 2000 Remote Control Panel A Appendix Specifications, Parts, and Accessories Specifications Part Numbers 4-10 Figure 4-7— ISS Control screen Using network switcher control T o use network switcher control, follow these steps: 1 .
RCP 2000 • Specifications, Parts, and Accessories Specifications, Parts, and Accessories, cont’d RCP 2000 • Specifications, Parts, and Accessories Part Numbers Extron Part Part Number RCP 2000 60-571-01 RS-232 male-male cable – 2' (.61 m) 26-434-01 RS-232 male-male cable – 4' (1.
RCP 2000 • Specifications, Parts, and Accessories Specifications, Parts, and Accessories, cont’d RCP 2000 • Specifications, Parts, and Accessories A-4 A-5.
RCP 2000 • Specifications, Parts, and Accessories Specifications, Parts, and Accessories, cont’d A-6.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Extron electronic RCP 2000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Extron electronic RCP 2000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Extron electronic RCP 2000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Extron electronic RCP 2000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Extron electronic RCP 2000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Extron electronic RCP 2000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Extron electronic RCP 2000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Extron electronic RCP 2000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.