User Guide MPS 601 HDMI Switchers Media Pr esentation Switcher 68-2454-01 Rev . A 03 14.
Safety Instructions Safety Instructions • English WARNING: This symbol, , when used on the product, is intended to alert the user of the presence of uninsulated danger ous voltage within the product’ s enclosure that may pr esent a risk of electric shock.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the FCC rules. The ClassA limits provide r easonable protection against harmful interference when the equipment is operated in a commer cial environment.
Conventions Used in this Guide Notifications The following notifications are used in this guide: CAUTION: A caution indicates a situation that may result in minor injury . A TTENTION: Attention indicates a situation that may damage or destroy the pr oduct or associated equipment.
v MPS601 Switcher • Contents Introduction ............................................................ 1 About this User Guide ........................................ 1 About the MPS601 ............................................ 1 Features .
MPS601 Switcher • Contents vi.
Intr oduction This section describes this guide and features of the MPS601, including: • About this User Guide • About the MPS601 • Features About this User Guide This guide contains information to install, configure, and operate the Extr on MPS601 Media Presentation Switcher .
Featur es • Presentation System Integration — Integrates HDMI, RGB, and audio sour ces into presentation systems. • Inputs — Includes four female HDMI type-A and two female 15-pin HD connectors for video; two female 3.5 mm TRS connectors for analog audio.
• EDID Minder — Automatically manages EDID communication between connected devices ensuring that all sources power up pr operly and reliably output content for display . • Key Minder — Continuously verifies HDCP compliance for quick, reliable switching.
Installation This section describes the installation and the operation of the MPS601, including: • Mounting the Switcher • Connections • Contact Closure and T ally Output Application Diagrams.
Power and Input A AC power — Connect to standard AC power: 100 to 240 V AC, at 50 or 60 Hz. DC Power Cord Captive Screw Connector AC Power Co rd External Power Suppl y (12 VDC, 1 A ) Ground +12 VDC 3/16" (5 mm) Max.
Control Devices F Contact In and T ally Out — Six 3.5 mm, 3-pole captive scrw connectors for automatic input switching and tally indication using Extron Show Me cables.
Contact Closur e and T ally Output Application Diagrams The following diagrams show examples of various connections using the contact enclosure and tally output feature of the MPS601.
-- A MA X POWER 12 V 1 2 B A 3 4 5 6 INPUTS MPS 601 CONTACT IN / TA LL Y OUT HDMI RGBHV HDMI HDMI RS-232 G C 135 246 TT CG T CG G CT T CG T +V CG Tx Rx G OUTPUT REMOTE Displa y HDMI Vide o an d Embe dded Audi o Vide o Vide o Audi o Vide o Audi o Audi o CC R 30 6 Cabl e Cubb y 80 0 Figure 9.
Lockit Lacing Brackets The included Lockit lacing brackets secure the HDMI cables to the r ear panel connectors as shown. The configuration of the HDMI connectors on the MPS601 rear panel r equire .
Cabling the MPS601 Switcher The switcher can be connected to asmany as six input devices (RGBHV and HDMI). It can output to one HDMI device or display . Follow the steps below and the installation example (see Figure 1 on page2). 1. T urn off power to the switcher and all devices that will be connected to it.
Operation This section discusses how to configure and operate the MPS601. T opics that are cover ed include: • Front Panel Featur es • HDCP • Audio Features • Auto-input Switching • Front.
HDCP The HDMI group is HDCP compliant. When EDID Minder is enabled (default), HDCP is not supported if adapters are used to pr ovide DVI inputs. HDCP communication occurs between the selected input source and the output device directly (pass-though).
Audio VGA Input A Following 1 Audio Input A Group Audio follows Input 1 or 2 1 VGA 2 HDMI HDMI HDMI HDMI 3 45 6 Audio Audio VGA Audio Input A Group Audio follows Input 1, 3, 5 Audio Input B Group Audi.
Autodetect for Audio Autodetect for audio is enabled when audio mode 3 is active. Audio InfoFrame data embedded in the digital signal is sampled to determine if audio is present on the selected HDMI stream. • If audio is present on the incoming str eam, it is selected for output.
EDID Minder The HDMI and RGBHV input groups featur e EDID Minder , ensuring that each input source reads the EDID of the output display even when the input is not selected. The r esult is the video source powers up pr operly and reliably outputs content when selected.
User assigned EDID Mode Using SIS commands, an EDID file can be selected from a table of 64 EDID files. Four additional EDID file locations are r eserved for user -loaded EDID files. Once a user assigned EDID is selected, it is stored at that input and EDID polling ceases for a connected display .
EDID Native Resolution Refresh Rate T ype Video Format Audio 33 800 x 600 60 Hz PC HDMI 2-Ch 34 1024 x 768 60 Hz PC HDMI 2-Ch 35 1280 x 768 60 Hz PC HDMI 2-Ch 36 1280 x 800 60 Hz PC HDMI 2-Ch 37 1280 .
Connection Options The MPS601 can be remotely connected to a host computer or other device (such as a control system) attached to the r ear panel RS-232 port or the front panel USB Config port. The switcher can be set up and controlled using Simple Instruction Set (SIS) commands.
Front Panel Configuration Port The USB mini B port is located on the front panel (see figur e 15, below). It is used to connect to a host computer for configuration using SIScommands with DataViewer or for updating firmware with the Firmwar e Loader utility .
3. Click Next . The following dialog opens: 4 4 5 5 Found Ne w Hardware Wizard We lcome to the Found New Hardware Wizard This W izard helps you install soft wa re fo r: If yo ur har d ware came with an installation CD or floppy disk , inse rt it no w.
Host-to-MPS Communications The MPS switcher accepts Simple Instruction Set (SIS) commands through the RS-232 or USB configuration port. SIS commands consist of one ormore characters per command field. They do not requir e special characters to begin or end the command character sequence.
Command and Response T able Using the Command and Response T able The command and response table is shown on the following pages. Lower case characters are acceptable in the command field only wher e indicated. Symbols are used throughout the table to repr esent variables in the command and response fields.
X1* = Mute LED mode 0 = Always on (default). 1 = Off, when muted. 2 = Blink, when muted. X1( = Name is a text string of up to 24 alpha-numeric characters and a minus sign or hyphen (-). No blank or space characters are permitted. No distinction between upper and lower case.
Command and response table for SIS commands Command ASCII Command (host to switcher) Response (switcher to host) Description Input selection Select input X! ! In X!• All ] Select input X! audio and video. View current input ! X! ] View active input X! .
Command ASCII Command (host to switcher) Response (switcher to host) Description Picture Adjustments (RGB Inputs only) NOTE: The specific input must be selected on the fr ont panel in order to make picture adjustments.
Command ASCII Command (host to switcher) Response (switcher to host) Description HDCP Management Set HDCP authorization per input E E X! * X^ HDCP } HdcpE X! * X^] X! = HDMI inputs 3-6 only Set HDCP a.
Command ASCII Command (host to switcher) Response (switcher to host) Description Information request General information I In X! Aw0 • Ausw X1% • Vmt X# • Amt X#] Video input (1-6), Audio input (1- 6), Autoswitch status, Video mute status, Audio mute status.
MPS601 • Software Configuration and Contr ol 28 Configuration Softwar e The Extron Pr oduct Configuration Software (PCS) provides a graphical user interface that includes the same functions as those on the front panel and pr ovides an additional way to configure the MPS601 using a USB or RS-232 connection.
MPS601 • Software Configuration and Contr ol 29 Starting the Softwar e Open the Product Configuration Softwar e program from the Start menu or desktop shortcut.
MPS601 • Software Configuration and Contr ol 30 Using the Softwar e The main PCS window opens on the Configuration page and the Input/Output Config panel selected. Under the device tab, PCS has two drop-down menus on the toolbar: Connections and Tools (see figure 21).
MPS601 • Software Configuration and Contr ol 31 Disconnect This option disconnects the PCS program fr om the device. From the Connections menu, click Disconnect . The MPS601 is disconnected but the PCS program r emains open. NOTE: If a device is already disconnected, the Disconnect option is disabled until the device is connected.
MPS601 • Software Configuration and Contr ol 32 3. Click Browse (see figure 24 on the pr evious page). 4. Navigate to the desired firmwar e file and select the device-specific firmware file. V alid firmware files have an .ef f or .esf file extension.
MPS601 • Software Configuration and Contr ol 33 Navigating the PCS Application The configuration software opens to two main tabs: Configuration and Hardware .
MPS601 • Software Configuration and Contr ol 34 Configuration Pages The Configuration tab global navigation bar has the following pages: • Input/Output Configuration – Provides an overview of the curr ent inputs and output configuration (see Input/Output Configuration on page34).
MPS601 • Software Configuration and Contr ol 35 Output Configuration panel The Output Configuration panel shows the current status of the output and allows color bit depth adjustment. • Output – The number is always 1. • Signal Presence – Indicates an active signal on the output.
MPS601 • Software Configuration and Contr ol 36 EDID Minder Page EDID Minder manages the EDID information between the switcher and one or more input sources.
MPS601 • Software Configuration and Contr ol 37 Available EDID panel EDID can be stored or imported as custom EDID files. Up to four custom EDID files can be stored in the switcher . Audio settings from custom EDID files take priority over current settings on the input.
MPS601 • Software Configuration and Contr ol 38 Adding EDID to the EDID Library 1. Click Add EDID to Library . The Browse Add EDID to Library dialog box opens. 2. Navigate to the desired EDID file location and select it. NOTE: V alid EDID files have a .
MPS601 • Software Configuration and Contr ol 39 Audio Config Page The MPS601 audio inputs have three modes that switch the active digital and analog audio inputs to the output. Figure 31. Audio Configuration Audio Configuration Mode 1 (default) – The associated audio input follows the selected input.
MPS601 • Software Configuration and Contr ol 40 Device Settings Page The Device Settings page allows configuration of the input auto-switching and the tally out LED indication. Click the Device Settings button on the Global Navigation Bar to open the page.
MPS601 • Software Configuration and Contr ol 41 Har dwar e Pages The Hardwar e pages contain unit information and options for device information, device naming, executive mode, and reset mode. Click the Hardware tab to open these pages. Figure 33.
MPS601 • Software Configuration and Contr ol 42 Executive Mode Page The Executive Mode page contains options for enabling or disabling the front panel lockout mode. When enabled, executive mode provides security fr om an accidental or unauthorized front panel button pr ess by locking out the input switching buttons.
MPS601 • Software Configuration and Contr ol 43 Reset Device Page This page allows the user to reset the device. Click Reset Device on the Global Navigation Bar to open the page. Figure 37. Reset Device Page There is one r eset option: Reset Device — Resets all settings on the device to factory defaults.
Refer ence Information This section discusses the specifications, part numbers, and accessories for the MPS601. T opics that are covered, include: • Mounting Options • DataViewer • Updating Firmware Mounting Options The MPS601 is housed in 1U tall, half rack width, six inches deep metal enclosure, rack- or desk-mountable.
RackMounting #10-32 Scre w w/ Nylon Captiv e Cap W asher Figure 38. Mounting the Switcher T able or W allMounting The table or wallmounting brackets extend approximately 1/4 inch (6.4mm) above the top surface of the switcher enclosure allowing for an air space between the enclosur e and the surface.
Through-deskMounting Mount the switcher through a desk or podium as follows: 1. Attach the mounting brackets to the switcher with themachine screws pr ovided. 2. Cut the proper sized hole in themounting surface. 3. Hold the switcher with the attached brackets against the underside of the table or other furniture.
Extron USB Device DataViewer DataViewer is an enhanced terminal emulation program that facilitates analysis of RS-232, USB, and TCP/IP communication with Extron devices. The softwar e allows users to send commands to a device and view the responses in ASCII or hexadecimal format.
Updating Firmwar e The MPS601 firmware can be updated using the PCS firmwar e update option (see Update Firmware on page31) or using the Extr on Firmware Loader program. T o update the firmware using either method, the latest firmwar e must first be obtained from the website.
Extron Headquarters +1.800.633.9876 (Inside USA/Canada Only) Extron USA - W est Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 F AX +1.919.850.1001 F AX Extron Europe +800.3987.6673 (Inside Europe Only) +31.33.453.4040 +31.33.453.4050 F AX Extron Asia +65.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Extron electronic MPS 601 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Extron electronic MPS 601 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Extron electronic MPS 601, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Extron electronic MPS 601 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Extron electronic MPS 601, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Extron electronic MPS 601.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Extron electronic MPS 601. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Extron electronic MPS 601 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.