Manuel d'utilisation / d'entretien du produit DMS 1600 du fabricant Extron electronic
Aller à la page of 25
Setup Guide 68-1829-50 Rev . C 09 13 DMS 1600, DMS 2000, DMS 3200, DMS 3600 Configurable Digital Video Matrix Switchers Matrix Switchers.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the FCC rules. The ClassA limits provide r easonable protection against harmful interference when the equipment is operated in a commercial envir onment.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Contents v Software Commands Commands are written in the fonts shown her e: ^A R Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C [01] R 0004 00300 00400 00800 00600 [0.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction 1 vi DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Contents Intr oduction WARNING : Risk of serious physical injury — The DMS ber optic I/O boards output continuous invisible light, which may be harmful to the eyes; use with caution.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction 2 3 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction About the DMS Matrix Switchers The DMS 1600, DMS 2000, DMS 3200, and DMS 3600 (see gure 1) are congurable matrix switchers that distribute DVI signals and DFX transmitter and receiver outputs and inputs.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 5 4 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction Installation This section describes installation of the DMS matrix switchers, including connections and features.
6 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 7 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation ANAHEIM, CA RESET RS232/RS422 REMOTE LAN ACT LINK REDUNDANT PRIMARY PRIMARY POWER SUPPL Y REDUNDANT POWER SUPPL Y FAN ASSIMB LY FAN ASSIMB LY 100-240V 50-60Hz 2.
8 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 9 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation e Remote port — If desired, connect a contr ol system or computer to the rear panel Remote RS-232/RS-422 port.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Front Panel Operations 11 10 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation Fr ont Panel Operations This section describes simple DMS matrix switcher operation from the front panel.
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 13 12 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Front Panel Operations Remote Contr ol This section describes using the remote contr ol features of the DMS matrix switchers to control the devices.
14 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 15 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Number of connections A switcher can have up to 200 simultaneous TCP connections, including all HTTP sockets and T elnet connections.
15 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Command and Response T able for SIS Commands Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description NOTES : • Commands can be entered back-to-back in a string, with no spaces.
16 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 17 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description EDID NOTE: In the commands below , the EDID data can come from either an active output or be set to a specied value.
18 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 19 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description Channel mute commands Channel mute X@ *1B Vmt X@ *1 ] Mute output X@ (no signal is output).
20 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control NOTE: X1! = Address nnn . nnn . nnn . nnn X1@ = DHCP 0 = off, 1 = on Command ASCII Command (host to unit) Response (unit to host) Additional Description IP and serial port setup Set IP address EX1! CI } Ipi X1!] Default: 192 .
21 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Installing and Starting the Control Pr ogram Another way to operate the switcher is via the Windows ® -based Matrix Switchers Control Pr ogram. This program is contained on the Extr on Software Pr oducts DVD (included with the switcher) or on the website.
22 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 23 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 4. Follow the on-screen instructions. The installation program cr eates a C:Program FilesExtr onMatrix_Switchers directory and an “Extr on ElectronicsMatrix Switchers” gr oup folder .
24 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 25 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 4. If you selected IP [LAN] in step 2, the IP Connection window appears. Figure 12. IP Connection Window a. Examine the Matrix IP Address eld, which displays the last Matrix IP address enter ed.
26 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 27 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 5. Execute a ping command by entering ping followed by a space and the new IP address at the command pr ompt. For example: ping 10 .
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 29 28 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Maintenance and Modifications This section describes repairing and r econguring the DMS matrix switchers by replacing components.
30 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 31 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications ANAHEIM, CA RESET REMOTE RS-232/RS-422 LAN BI-LEVEL TRI-LEVEL ACT LINK 100-240V 50/60Hz 1.2A MAX.
32 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 33 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 3. Slide the power supply out of the chassis. 4. Orient the power supply module to be installed with the LED to the right.
34 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications.
Extron W arranty Extron Electr onics warrants this product against defects in materials and workmanship for a period of three years fr om the date of purchase.
Extron USA Headquarters +800.633.9876 (Inside USA/Canada Only) Extron USA - W est Extr on USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 F AX +1.919.850.1001 F AX Extron Europe +800.3987.6673 (Inside Europe Only) +31.33.453.4040 +31.33.453.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Extron electronic DMS 1600 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Extron electronic DMS 1600 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Extron electronic DMS 1600, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Extron electronic DMS 1600 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Extron electronic DMS 1600, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Extron electronic DMS 1600.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Extron electronic DMS 1600. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Extron electronic DMS 1600 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.