Manuel d'utilisation / d'entretien du produit EVS200A/AW du fabricant EverFocus
Aller à la page of 51
EVS200A/A W User ’ s Manual Copyright © EverFocus Electronics Corp, Release: Nov . 2009 Rev .A.
EVS200A/A W 2 Product Name: EVS200A/A W EverFocus IP V ideo Encoder Model Number(s): EVS200A/A W FCC Notice "Declara tion of Conformity Information" RF Declaration should be added.
EVS200A/A W 3 EVS200A/A W complies with CE and FCC. About this document All the safety and operating instructions shou ld be read and followed before the unit is operated. This manual should b e retained for future reference . The information in this manual was current when publish ed.
EVS200A/A W 4 remove, use a mild detergent and wipe gently . Do not operate the appliance beyond it s specified temperature, humidity or power source ratings. Do not use the appl iance in an extreme environment where high temperature or high hu midity exists.
EVS200A/A W 5 T ABLE OF CONTENTS 1. INTRODUCTION.......................................... .......................................................... 6 2. FEA TURES ......................................................................................
EVS200A/A W 6 1. INTRODUCTION The EVS200A/EVS200AW is a high performance, two channel solution that integrates analog cameras into an IP-based video surveillan ce system. The unit supports NTSC/PAL sources at up to 30fps , per chann el, over IP network s and provides bidirectional audio communication in parallel with video.
EVS200A/A W 7 3. ACCESSING THE CAMERA MENU Step 1.S tart an Internet Explorer browser . Step 2. Enter the IP address or host na me of the camera in the Location/Add r e ss field of your Internet Explorer browser . (Please refer to EVS200A/A W Installation Guide for how to find the IP address) Step 3.
EVS200A/A W 8 1. Press button to enter Nevio Express system. For m ore details, please refer to Nevio Express user manual. 2. Press button to display the "Live" page. Double click on the image to show a full screen display , double click again or press ESC to return normal display .
EVS200A/A W 9 6. V iew Size Y ou can s elect V iew size to eith er reduce or enlarge the image to th e appropriate view size. Select the view size for live images from : NTSC: 704*480/640*480/352*240/3 20*240/176*120 P AL: 704*576/640*480/352*288/320*240/176*144 7.
EVS200A/A W 10 12. PTZ C ont rol – Navigation Mode Select this to browse in direction user pointing at. 13. PTZ C ont rol – Click-n-Go Mode Select this and system will center the pointing location for browsing. Before Click-n-G o mode After Click-n-Go mode EVS200A/A W provides 3 methods to control PTZ: 1.
EVS200A/A W 11 ○ 1 Control Panel : Zoom in : Zoom out : Focus far Fo cus near : Ir is + : Iris – Arrow buttons: Click on an arrow button to navigat e in th at directio n. : stop c urrent acti on. : User can select PTZ s peed from High, Standard, Low and Minimum.
EVS200A/A W 12 Num ber button, Go b utto n an d Cle ar button : - Click desire number button and it will show in the gray text area at lower-left corner . - Click “Clear” bu tton to cl ear the text ar ea. - Click “Go” button to run a selected function.
EVS200A/A W 13 Motion Alarm 2 Alarm 1 ○ 3 PTZ Control Shortcuts Right click the mouse to get a PTZ Control Sho rtcuts panel. User can control the PTZ through a PC’ s keyboard.
EVS200A/A W 14 4. SETTING Click “Setting” button to enter the setting menu. There are 9 sections in setup menu: [Syste m Info], [User Conf ig], [Networ k], [V id eo], [Audio], [U ser], [Event], [Sy stem] and [EKB200]. 4.1 System Info System information and system log check of the setup menu can be performed on this page.
EVS200A/A W 15 4.1.2 Log System Log : Date/Time : displaying date and tim e of the log. Log message : all information and event message, including login, user ’ s IP , reboot, firmware upgrade, load factory default, configuration reset and event detected.
EVS200A/A W 16 Press button to export syste m log into “.txt” file and select the location where the exported log file will be sav ed to. 4.2 User Config Live view configuration is to b e set by user .
EVS200A/A W 17 Date/T ime Format Used in T ext Date Format: Select Date/Time Format from the following options: T i me Format: 24 Hours or 12 Hours. Press Apply to apply the setting changes or Reset to res et without saving the change.
EVS200A/A W 18 the new language file (.evb) and then click the Upload button. Press Apply to apply the setting changes or Reset to res et without saving the change. 4.3 Network The network settings and the settings relating to Network, DDNS, Bandwidth, SMTP/FTP and Network Alarm can be configured on this page.
EVS200A/A W 19 • Primary DNS, Secondary DNS (when using DNS) IP Setting IP T ype: DHCP: Configure th e DHCP server not to assign the s ame IP address es used for the other network cameras and PCs w hose IP address is unique. Refer to the network ad ministrator for the settings of the server .
EVS200A/A W 20 Usern ame : Enter User name of the account (used only for PPPoE). Password: Enter Password of the account (used only for PPPoE). Press Apply to apply the setting changes or Reset to res et without saving the change. Port Setting HTTP Port: Port number for HTTP/WEB communication.
EVS200A/A W 21 necessary . T o use the DD NS function, it is necessary to conn ect to the dedicated DDNS server . W e of fer 4 DDNS server provi ders as follow: ○ www .everfocusddns.co m ○ www .sitelutions.com ○ www .dy ndns.com ○ www .no-ip .
EVS200A/A W 22 Bandwidth Setting Max. Bandwidth: Specify , Unlimited / 64 K/ 128 K/ 256 K / 512 K / 1M / 2M / 4M / 8M bps. the maxi mum bandwidth that the camera is allowed to use on the network. This is a useful function when connecting the ca mera to busy or heavily loaded networks.
EVS200A/A W 23 send e-mails . SMTP Port: Enter the port number for SMTP . Default is 25. Authentication: Check the box, if the SMTP server requires Authentication (user/ password). User name: Input the login user ID if th e SMTP server requires Authenti cation.
EVS200A/A W 24 4.3.5 Network A larm (re served for PowerCon) Set Network Alarm This function is reserved for PowerCon software, for the detail setting please refer to PowerCon network alarm protocol.
EVS200A/A W 25 W ireless S etting Enable W ireless (Default: disable ) SSID: Nam e of the wireless network the camera is configured for . The field accepts up to 32 alphanu meric characters. The name must be exactly the sa me as the one used in the wireless access point or the con nection will not be established.
EVS200A/A W 26 Confirm Key: Double confirm network key . IP St atus: Show IP status when wireless connection, including IP T ype, IP Address, Subnet mask, Gatew ay , P rimary DNS, Secondary DNS. Pres s Apply to apply the setting chan ges or Reset t o reset without saving the change.
EVS200A/A W 27 Resolution: NTSC: 4CIF (704*480) / VGA (640*480) / CIF (352*240) P AL: 4CIF (704*576) / VGA (640*480) / CIF (352*288) Quality: there are 8 ty pes of quality , pleas e choose from Highest / Higher / High / Middle / Normal / Low / Lower / Lowest.
EVS200A/A W 28 4.4.2 V ideo - Camera Channel: add channel selection. Came ra Settings Channel title: ad d channel title. PTZ function: select PTZ function ON or OFF ID: This entry is used to assign the own ID code of channel 1 camera. Protocol: Select protocol from Everfocus, P elco-D, Pelco-P , Samsung an d Panasonic.
EVS200A/A W 29 Whenever the above three pictur e parameters are adjus ted, the values will be set to th e channel automat ically . Press Apply to apply the setting changes or Reset to res et without saving the change.
EVS200A/A W 30 Audio Input volume: Adjust the Audio Input V olume for the audio input devices connected to the camera if there are problems with the sound input being too low or high. Press Apply to apply the setting changes or Reset to res et without saving the change.
EVS200A/A W 31 • Guest - the lowest level of access, which only allows the user a ccess to the Live Vi e w p a g e . Note: Please select Active in Status sec tion to ac tivate user a ccount. Press Apply to apply the setting changes or Reset to res et without saving the change.
EVS200A/A W 32 4.7 EVENT An event in the camera is when an Event T y pe is activated and caus es certain actions to be performed. The e vent type is the set of conditions that specifies how and when which actions will be performed. This table describes how to setup action types and event ty pe.
EVS200A/A W 33 Press button to add an event condition. T o modify the event list, click on th e event and it will be highlighted. Press button to modify the setting. T o remove an event from event list, click on the event and it will be highlighted. Press button to remove the event.
EVS200A/A W 34 1. Click button in Event pag e. 2. Enter an ev ent name for the event, e.g. Event 1 3. Select “Manual T rigg er” as event type. 4. Select “Upload to FTP” as action type. 5. Check “Enable Pre-alarm Buf fer” and “Enable Post-alar m Buf fer”.
EVS200A/A W 35 4.7.2 Motion Motion Detection First, select the channel for motion detection setting. User can define the motion area to be detected by left cli cking the mouse to draw lines. Every click is an end point of the line. When the detec tion area is formed, double click the mouse to have all the lin es connected.
EVS200A/A W 36 4.7.3 Alarm Alarm Output Setting Conta ct T ype: No rmal Close, No rmal Ope n Duration T ime: Select duration time of alarm output from 5 sec, 10 sec, 20 sec, 30 sec, 60 sec, 2 min, 3 min and 5 min. Press Apply to apply the setting changes or Reset to res et without saving the change.
EVS200A/A W 37 Re-trigger Filter Setting Re-trigger Filter: Set a re-trigger filter time, if another event is triggered during this time, this triggered event will be ignored. Press Apply to apply the setting changes or Reset to res et without saving the change.
EVS200A/A W 38 An example on how to set weekend as time mask: 1. Click f ro m time mask sett ing. 2. Enter Mask name, e.g. W eekend. 3. Check “Sun” & “Sat” boxes. 4. Select “Start time” and “End time” or “Full day”. Press Apply to apply the setting changes or Reset to res et without saving the change.
EVS200A/A W 39 Press Apply to apply the setting changes or Reset to res et without saving the change. Set T ime Zone T ime Zone: Select a time zone according to the lo cation where the camera is in use. Press Apply to apply the setting changes or Reset to res et without saving the change.
EVS200A/A W 40 Press Apply to apply the setting changes or Reset to res et without saving the change. 4.8.2 Daylight Saving Set Daylight Saving Ti c k Enable Daylight Saving checkbox to en able daylight saving. Set the start time to daylight sav ing time.
EVS200A/A W 41 May / June / July / Augus t / September / October / November / December . Set the ending tim e change of daylight saving time: Choose the “From” time and “End” time when daylight saving ends. Press Apply to apply the setting changes or Reset to res et without saving the change.
EVS200A/A W 42 disconnected . Normal: Follow the event actions settings you have made in “Event” menu to record event video to S D card. Overwrite: Select ON for overwriting data when SD card memory is full. Select OFF for not overwriting SD card data.
EVS200A/A W 43 4.8.4 Serial Commun ication RS485 Setting Baud Rate: This field is to set the speed at whi ch is used to trans mit instruction or information through the RS485 port on the camera. There are six dif ferent speeds, 2400/4800/9600/19200/38400/57600.
EVS200A/A W 44 4.8.5 Maintenance Maint enance Se rver Reboot: The unit is rebooted without changing any of the settings. Use this method by pressing Reboot button if the unit is no t behaving as expected. Restore: The unit is restarted and most current settings are reset to the factory defaul t values by press ing Re stor e button.
EVS200A/A W 45 Upgrade Firmware Upgrade the EVS200A/A W with the latest firmware. Press Br owse button to search firmware file. Press Upgrade button to upg rade the firmware. 4.9 EKB200 4.9.1 Action List EKB200 Button Mapping EKB-200 is an IP surveillance keyboard controller powered by US B port.
EVS200A/A W 46 to Key No.12) can be set. Us er can choose action and set value for each Key No. If the comman d requires a value, su ch as GoT o P reset [x] or T our [x], user needs to enter the number [x] in the field "V alue". Otherwise, the va lue option will be disabled.
EVS200A/A W 47 EKB200 Panel There are 20 available Action o ptions, including: 1. Set Pre set : When the action of a key is set “Set Prese t”, use joystick to s elect a position and press this key on KEB200 to sav e the position as Preset Point. 2.
EVS200A/A W 48 KEB200 to start autopan. 10. St o p A u t o p a n : When the action of a key is set “Stop Autopan”, press this key on KEB200 to stop autopan. 11. OSD Men u On : When the action of a key is set “OSD Menu On”, press this key on KEB200 to display OSD Menu on the screen.
EVS200A/A W 49 5. SPECIFICA TIONS VIDEO STREAMING Video Compre ssion H.264/MPEG-4/M-JPEG Vide o Resolution 4CIF , VGA, CIF , QVGA, QCIF Video Quality 8 le vels adjustable Frame Rate Up to 30fp s Video.
EVS200A/A W 50 ENVIRONMENT AL Operating T emp. 0°C ~40°C / 32°F~104°F Humidity (20%~80% Humidity).
EVS200A/A W 51 China Office: Room B-05D-1, KESHI PLAZA, Shangdi Information Industry Base,Haidian District, Beijing China 100085 TEL: +86-10-62973336/37/38/39 F AX: +86-10-62971423 www .everfocus.co m.cn Eur ope Offi ce: Albert-Einstein-Strasse 1 D-46446 Emmerich, Germany TEL: 49-2822-9394-0 F AX: 49-2822-939495 www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté EverFocus EVS200A/AW c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du EverFocus EVS200A/AW - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation EverFocus EVS200A/AW, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le EverFocus EVS200A/AW va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le EverFocus EVS200A/AW, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du EverFocus EVS200A/AW.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le EverFocus EVS200A/AW. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei EverFocus EVS200A/AW ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.