Manuel d'utilisation / d'entretien du produit RX8320 du fabricant Ericsson
Aller à la page of 36
RX8320 ATSC Broadcast Receive r Software Version 4.3.2 USER GUIDE EN/LZT 790 0008/2 R1A.
RX8320 ATSC Broadcast Receiver Copyright © Copyright Ericsson AB 2011. All rights reserved. Disclaimer No part of this document may be reproduced in any form without the written permission of the copyright owner.
Contents Contents 1 Introduction ............................................................................................ 5 1.1 Who Should Use this User Guide? .......................................................... 5 1.2 What Equipment is Covered by this User Guide? .
Contents EN/LZT 790 0008/2 R1A 2011-03 -30 4 (36) List of Figures Figure 1 Rear Panel Connectors ............................................................................8 Figure 2 Front Panel LEDs and Pushbuttons ..................................
Introduction 1 Introduction 1.1 Who Should Use this User Guide? This User Guide is written for operators/users of the RX8320 ATSC Broadcast Receiver to assist in installation and operation. Detailed infor mation can be found in the Reference Guide companion document which is issued on CD.
Introduction T able 2 RX8320 Hardware Options Marketing Code Price Object Number Supply Object Number Description RX8XXX/CABLE/XLR FAZ 101 0108/24 RPM 901 364 XLR Terminal Audio Brea k-out Cable RX8XX.
Installing the Equipment 2 Inst alling the Equipment 2.1 Introduction For best performance and reliability follow the instructions for site requirements and installation in the Reference Guide and only use installation accessories recommended by the manufacturers.
Installing the Equipment Warning! The Technical Earth is not a Protective earth for electric shock protection. This unit must be correctly earthed through the molded plug supplied. If the local mains supply does not have an earth conductor do not connect the unit.
Installing the Equipment ) Type of Connector Description ALARM 9-way male D-type connector for alarm signal output. AC POWER IEC100-120 V AC / 220-240 V AC power input.
Quick Start Guide: Connect- P ower - Configure 3 Quick S tart Guide: Connect-Power-Configure 3.1 Connecting the Receiver The following points should be noted when making signal connections to the receiver: • If you have an incoming 8VSB feed, this should be connected to the rear panel connector marked RF INPUT .
Quick Start Guide: Connect- P ower - Configure 4. During initialization, confirm that the Status LED is on and all Up , Down , Left , Right , Edit and Save pushbuttons are lit. 3.2.2 Power Up Operating Modes When the equipment is switched on it will assume the control mode that was set when the power was turned off.
Quick Start Guide: Connect- P ower - Configure • The unit will automatically decode the first video component that it finds w ithin the selected service. • An alternative video component may be selected from the service tab on the Web Control interface.
Quick Start Guide: Connect- P ower - Configure and Maximum CAM Components Per Service dialog boxes. The user should refer to the CAM vendor for CAM compatibilities before setting this up. • This list may be modified from the CA tab on the Web Control interface.
Front P a nel C ontrol 4 Front Panel Control 4.1 Introduction The Front Panel display and keypad may be used to configure, control and monitor the receiver when an external control system is not used.
Front P a nel C ontrol 4.3.2 LCD A 2-line x 40-character back-lit dot-matrix Liquid Crystal Display (LCD) displays various menus and settings. The menus and setting available will vary depending on which options have been enabled through the purchase of a suitable lice nse.
Front P a nel C ontrol 4.4 Front Panel Menus An overview of the available Front Panel menus is shown below. The menus and settings available will vary depending on which receiver model is being used and which options have been enabled through the purchase of a suitable lice nse.
Front P a nel C ontrol 4.4.1 Menu Structure The Front Panel menus and sub-menus, av ailable on the LCD, provide the configuration parameters that may be viewed, selected and/or modified. • System - Provides sub-menus for viewing/config uring the receiver hardware and access parameters.
Front P a nel C ontrol • Output Menu - Provides sub-menus for viewing/configuring the receiver output parameters. - Output Selection - Enables selection of the required output type. - TS Feed Selection - Enables selection of the descrambling for the Transport Stream Feed.
Web Br o w ser Control 5 W eb Browser Control 5.1 Introduction A personal computer (PC) running a Web Browser can be used to configure, control and monitor the receiver remotely.
Web Br o w ser Control Unit Model Number and Name About button Header Function Tabs Navi g ation Path Toolbar Main Web Page Results Frame Figure 4 Web Page Overview (T ypical) • Header – The header of the web page displays the Ericsson logo and the unit model number name.
Web Br o w ser Control web page. When you switch between tabs, the browser remembers the path for each tab. • Navigation Path – The web pages are organized into a tree-like structur e, like the directory on a computer.
Web Br o w ser Control 5.3 W eb Pages 5.3.1 Status This web page shows a number of top-level parameters indicating the current status of the receiver. Figure 6 S t atus Web Page 5.
Web Br o w ser Control Figure 7 Device Info Web Page This page also provides buttons to the following further web pages: • Build – provides details of equipment build and version numbers. No user- editable fields. • Environment – provides details of the phy sical environment of the equipment such as temperature and fan speed.
Web Br o w ser Control 5.3.3 Alarms The Alarms web page provides access to the alarms settings for the receiver. The contents of this page are composed mainly of fields with drop-down menus which allow the setting or masking of various alarms and check boxes which can be used to activate relay mapping.
Web Br o w ser Control Figure 8 Alarms W eb Page 5.3.4 Customization Web Page The Customization web page provides acce ss to the list of licenses enabled on the equipment and to enable further licenses (as purchased) by entering the custom key provided.
Web Br o w ser Control Figure 10 CA W eb Page 5.3.6 Input The Input Web Page provides access to the parameters of the various inputs to the receiver. The page, which is displayed, depends on which Input card is fitted.
Web Br o w ser Control Figure 1 1 Input Web Page (8VSB Input Card fitted) 5.3.7 Service Plus The Service Plus web page provides access to the various encryption and encoding services available to the receiver. A Se rvice Control table is displayed showing which services are available.
Web Br o w ser Control • Splice - gives access to the splice operation parameters. • DVB Subtitles - gives access to the Digital Video Broadcasting (DVB) subtitles parameters.
Web Br o w ser Control 5.3.9 Output The Output web page provides access to the output feed parameters of the receiver. Figure 14 Output Web Page 5.3.10 Download The Download web page provides access to the over air download status of the receiver. There are no user-editable fields on this page.
Web Br o w ser Control Figure 15 Download Web Page 5.3.11 SNMP This page gives access to the Simple Network Management Protocol (SNMP) parameters for the receiver, including protocol selection and MIB parameters. Figure 16 SNMP Web Page 5.3.12 Presets The Presets web page gives access to a list of 40 preset configurations.
Web Br o w ser Control Figure 17 Presets W eb Page 5.3.13 Save/Load The Save/Load web page provides a range of configuration download and upload facilities, including saving and restoring unit confi guration, saving unit MIB files, saving alarm log files and saving splice log files.
Web Br o w ser Control Figure 18 Save/Load Web Page 5.3.14 Help The Help web page gives access to a Web Interface User Guide which provides a brief description of the interface functionality.
Equipment P a ckaging 6 Equipment Packaging 6.1 Packaging S t atement The outer carton and any cardboard inserts are made from 82% recycled material and are fully recyclable. The Stratocell ® or Ethafoam 220 ® polyethylene foam inserts can be easily recycled with other low density polyethylene (LDPE) materials 6.
Materials Declarations 7 Materials Declarations 7.1 Overview Ericsson products are designed and manufactured in keeping with good environmental practice. Our component and materials selection policy prohibits the use of a range of potentially hazardous materials.
Disposal of this Equipment 8 Disposal of this Equipment 8.1 General Dispose of this equipment safely at the end of its life. Local codes and/or environmental restrictions may affect its disposal. Regulations, policies an d/or environmental restrictions differ throughout the world.
Re c y cling EN/LZT 790 0008/2 R1A 2011-03 -30 36 (36) 9 Recycling Ericsson SA TV Recycling has a process facility that enables customers t o return Old and End-of-Life Products for recycling if it is required. Ericsson provides assistance to customers and recyclers thr ough our Ericsson and SATV Recycling eBusiness Portal.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Ericsson RX8320 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Ericsson RX8320 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Ericsson RX8320, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Ericsson RX8320 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Ericsson RX8320, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Ericsson RX8320.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Ericsson RX8320. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Ericsson RX8320 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.