Manuel d'utilisation / d'entretien du produit DVX42DP91(N,P)-1 du fabricant Empire Comfort Systems
Aller à la page of 72
LUXUR Y DIRECT VENT GAS FIREPLACE HEA TER MODEL SERIES MILLIVOL T ST ANDING PILOT DVX36DP31(N,P)-1 DVX42DP31(N,P)-1 INTERMITTENT PILOT DVX36DP71(N,P)-1 DVX42DP71(N,P)-1 REMOTE RF DVX36DP91(N,P)-1 DVX42DP91(N,P)-1 UL FILE NO.
25613-0-0309 Page 2 Important Safety Information ..................................................................................................................................... 3 Safety Information for Users of LP Gas ...........................
25613-0-0309 Page 3 DO NOT OPERA TE THIS APPLIANCE WITHOUT GLASS FRONT P ANEL INST ALLED Before enclosing the vent pipe assembly , operate the appliance to ensure it is venting pr operly .
25613-0-0309 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must nd out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
25613-0-0309 Page 5 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residentia.
25613-0-0309 Page 6 Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner ll out and mail warra nty card suppl ied with the replace. 3. Installer should show owner how to start and operate the replace.
25613-0-0309 Page 7 Figure 1 LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW ELECTRICAL ACCESS VENT COLLAR TO P VIEW GAS LINE ACCESS A C J G I GAS LINE ACCESS H D E B VENT COLLAR ST ANDOFFS NAILING FLANGES .
25613-0-0309 Page 8 Mantel Chart (Figure 3) Figure 3 Clearances (Figure 4) Clearance from top front edge of replace to ceiling is 36" Clearance from side of replace to adjacent sidewall is 6".
25613-0-0309 Page 9 Figure 6 The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code. Installing a New Main Gas Cock Each appliance should have its own manual gas cock.
25613-0-0309 Page 10 Framing and Finishing 1. Choose unit location. 2. Frame in replace with a header across the top. It is important to allow for nished face when setting the depth of the frame. 3. Attach replace to frame using adjustable nailing ange.
25613-0-0309 Page 1 1 Figure 1 1 Attention: If a base is not used and the appliance is installed directly on tile or other combustible material other than wood ooring, it shall be installed on a metal or wood panel extending the full width and depth of the appliance.
25613-0-0309 Page 12 Flush W all Installation Figure 12 Combustible Surround Installation Figure 13 V ent Runs (Figures 14, 15, and 16) In planning the installation for the replace, it is necessary to install certain components before the appliance is completely positioned and installed.
25613-0-0309 Page 13 CORNER INST ALLA TION VER TICAL, 90° ELBOW TO HORIZONT AL OUT THE W ALL Figure 16 VER TICAL, 90° ELBOW T O HORIZONT AL OUT THE W ALL Figure 15 90º ELBOW “A” PIPE LENGTH VEN.
25613-0-0309 Page 14 T o Use the V ent Graph (Figure 17) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall V ent Graph, locate the point it intersects with the slanted graph line. 2. From the point of this intersection, draw a vertical line to the bottom of the graph.
25613-0-0309 Page 15 VENTING FIREPLACE - TOP (continued) Installation of Flue Heat Shield 1. Remove ue insulation. 2 . Remove (2) screws on outside of inlet vent adapter . See Figure 18. 3. Lift top shield placing ue heat shield around ue. 4.
25613-0-0309 Page 16 Figure 21 Examples of possible venting systems using two (2) 90° elbows. V is listed as minimum vertical dimensions and H1 + H2 is listed as total of maximum horizontal dimensions. The maximum vertical and horizontal distances for two (2) 90° elbows as shown in Figure 22 is 22 feet.
25613-0-0309 Page 17 VENT CAP 9” (229mm) minimum TO SIDE W ALL Figure 25 Figure 24 MINIMUM HOLE LOCA TION DIMENSIONS FOR THROUGH THE W ALL HORIZONT AL INST ALLA TIONS WITH 90 DEGREE ELBOW OFF TOP OF.
25613-0-0309 Page 18 Figure 28 Figure 26 Figure 27 Example H2 3ft, H3 1f t= 4ft (90 °+ 90 °+ 90° )= 6ft V 1= 21ft H= 10ft V= 21ft Example H 1= 2ft V 1= 20ft H= 2ft V= 20ft EXAMPLES - TOP VENT RUN.
25613-0-0309 Page 19 Installation Instructions This termination kit can only be used with Empire Comfort Systems direct vent replaces listed for use with DVVK-4FV V ertical Flex V ent Kit. Please review the instructions packaged with your replace and verify the replace model number .
25613-0-0309 Page 20 PRE-INST ALLA TION INFORMA TION: Items Required For Installation: T ools Building Supplies Phillips Screwdriver Hammer Saw and/or saber saw Level Measuring T ape Electric Drill an.
25613-0-0309 Page 21 1. Unpack vent components and check all items for shipping damage. 2. For this venting system to operate as designed it is depen- dent on the use of all parts and procedures detailed in these instructions.
25613-0-0309 Page 22 10. W ith the ex vent assembly and the 48” long hard pipe com - ponents laid out on the oor , begin securing these parts to - gether .
25613-0-0309 Page 23 17. T o attach the vent connections at the replace, be sure the 7” diameter adapter collar has been installed per step 3. Apply a bead of silicone sealant to the 4” diamete.
25613-0-0309 Page 24 VERTICAL TERMINA TION 4’ LONG RIGID PIPE ROOF FLASHING ROOF EXTERIOR CLAMPS AT FLUE & INLET VENT CONNECTIONS STORM COLLAR (USE TO KEEP INSULA TION OUT OF THIMBLE ASSEMBL Y) FIRESTOP/THIMBLE 4” DIA. FLUE CONNECTOR 7” DIA.
25613-0-0309 Page 25 V ertical Flex T ermination Kit Item Number Item Description Repair Part No. Quantity Supplied 1 4”/7” V ertical T ermination Cap MF100038 1 2 Roof Support Kit MF100503 1 3 2 Ply Alum Flex 4” Diameter by 6 ft. MF04ALA2F006 1 4 2 Ply Alum Flex 7” Diameter by 6 ft.
25613-0-0309 Page 26 CAUTION: Sharp edges, use protective gloves when installing. T ools Needed for Installation: Sheet metal snips 5/16” nut driver Phillips head screwdriver - #2 High temperature s.
25613-0-0309 Page 27 7. Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6 5/8” (168 mm) diameter tube from the opposite end. Do not crimp or enlarge tube. 8. Attach the 4” (102 mm) diameter ue outlet tube onto the rigid venting system or directly to replace.
25613-0-0309 Page 28 Follow correct option according to venting method. Connecting Directly to Fir eplace If the air inlet and ue outlet tubes are to be connected directly to the unit (no rigid venting system is being used), then the gasket provided must be used to seal the 4” (102 mm) ue outlet tube.
25613-0-0309 Page 29 INST ALLA TION 1. Unpack vent components and check that all items are included. 2. Check to see that the vent spacer springs are located around the ue vent at 8" and 12" intervals along its length.
25613-0-0309 Page 30 T ermination clearance for buildings with combustible and noncombustible exteriors. V ertical Sidewall Installations Important! Minimum clearance between vent pipes and combustible materials is three (3") (76 mm) on top, and (1") (25 mm) on bottom and sides.
25613-0-0309 Page 31 Figure 47 VENT TERMINAL AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED A = *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum] B = clearanc.
25613-0-0309 Page 32 VERTICAL TERMINA TION (MAXIMUM OF THREE 90° ELBOWS) STOR M C OLLAR ROOF FLASHING W ALL THIMBLE HORIZONT AL TWO 90° ELBOWS) TERMINA TION (MAXIMUM OF 90° ELBOW OR 45° ELBOW 90°.
25613-0-0309 Page 33 Installing Support Brackets (Figure 49) A hori zontal pipe suppo rt MUS T BE used for eac h 3 feet of hori zontal run. The pipe supports should be placed around the pipe and nailed in place to framing members.
25613-0-0309 Page 34 A B NAILS ,4 REQUIRED CEILING FIRESTOP EXISTING CEILING JOISTS NEW FRAMING CEILING BELOW B A NAILS ,4 REQUIRED CEILING FIRESTOP A B FRAMING AND FINISHING (continued) V ent Size A .
25613-0-0309 Page 35 NOTE: T ermination cap should pass through the wall restop from the exterior of the building. Adjust the termination cap to its nal exterior position on the building. W arning: T ermination cap must be positioned so that arrow is pointing up.
25613-0-0309 Page 36 INST ALLA TION 1. Unpack vent components and check that all items are included. 2. Check to see that the vent spacer springs are located around the ue vent at 8" and 12" intervals along its length.
25613-0-0309 Page 37 Locate and mark the center point of the venting pipe. Using a nail on the underside of the roof and drive this nail through this center point. Make the outline of the roof hole around this center point. NOTE: Size of the roof hole dimensions depend on the pitch of the roof.
25613-0-0309 Page 38 V ertical Thr ough the Roof Applications (Figure 62) Y our Gas Fireplace has been approved for: a) V ertical installations up to 40 feet in height. b) T wo sets of 45 degree elbow offsets within these vertical installations. From 0 to a maximum of 8 ft.
25613-0-0309 Page 39 LOG IDENTIFICA TION REAR BOTTOM LOG (A) REAR T OP LOG (B) Part Number - R9228 Part Number - R9222 BOTTOM LEFT LOG (C) BOTTOM LEFT CENTER LOG (D) Part Number - R9227 Part Number - .
25613-0-0309 Page 40 6. Place Bottom Left Log (C) on far left pin of burner . The "lip" of the log will hang off the side of the burner . 7. Place Bottom Left Center Log (D) on second and third pins from left side of the burner . 8. Place Bottom Right Center Log (E) on fourth and fth pins from the left side of the burner .
25613-0-0309 Page 41 LOG PLACEMENT (13 LOG SET) 9. Pla ce Bottom Right Log (F) on far right pin on the burner . The "lip" of the log will hang off the side of the burner . 10. Place Front Left Log (G) on (C) Log pin. End of (G) Log will rest on rebox bottom.
25613-0-0309 Page 42 LOG PLACEMENT (13 LOG SET) 15. Place Front Center Log (L) between third and fourth grates on the burner . The short "Y" branch will point left and the bottom of the "Y" resting on the rebox bottom. 16. Place Front Right Log (M) on the fth grate from the left with the top resting on (K) Log.
25613-0-0309 Page 43 Log Set Parts List Index Letter Part Number Description A R9228 Rear Bottom Log B R9222 Rear T op Log C R9227 Bottom Left Log D R9372 Bottom Left Center Log E R9225 Bottom Right C.
25613-0-0309 Page 44 The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the gas controls for the replace. Initial Lighting Upon completing the gas line or turning the gas valve on after it has been in the “OFF” position, a small amount of air will be in the lines.
25613-0-0309 Page 45 ST ANDING PILOT OPERA TING INSTRUCTIONS Remote/Off/On Switch The replace is equipped with a Remote/OFF/ON switch. A wire harness is attached to the Remote/OFF/ON switch. The red, black and green (wires) female push-ons attach to the Remote/OFF/ ON switch.
25613-0-0309 Page 46 Figure 69 REMOTE CONTROL RECEIVER GAS VA LV E REMOTE/OFF/ON SWITCH (OPTIONAL) REMOTE CONTROL RECEIVER REMOTE/OFF/ON SWITCH REMOTE OFF ON THERMOPILE IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH NO.
25613-0-0309 Page 47 1. Stop! Read the safety information above. 2. Set REMOTE/OFF/ON switch to OFF . 3. T urn off all electric power to the appliance (if applicable). 4. Lower bottom louver assembly . 5 . Push in gas control knob slightly and turn clockwise to "OFF .
25613-0-0309 Page 48 With proper installation and maintenance, your new Direct V ent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the T rouble Shooting Guide below . This guide will assist a qualied service person in the diagnosis of problems and the corr ective action to be taken.
25613-0-0309 Page 49 1. T o wire Junction Box Receptacle, remove the tab on the side of the receptacle (hot side) to split receptacle. This will be required to separate blower and valve circuits. 2. Power for switched and live sides of Duplex Receptacle must come from the same power source.
25613-0-0309 Page 50 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a re or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the pilot.
25613-0-0309 Page 51 GENERAL: All replaces have been re-tested to check for proper operation. This includes, main burner ame, pilot ame, fan operation, fan control, limit control and automatic valve operation. If the replace fails to function on initial installation, it is advisable to re-check the following: 1.
25613-0-0309 Page 52 Spark Generator Powered First V alve (Pilot) Operator Opens Pilot burner lights. Module senses flame current. PILOT BURNER OPERA TION MODULE S8600H * Lockout timing is stamped on module. RESPONSE After 90 seconds*pilot valve closes, spark stops.
25613-0-0309 Page 53 Important 1. The following service procedures are provided as a general guide. 2. Meter readings between gas control and ignition module must be taken within the trial for ignition period. Once the igni- tion module locks out, the system must be reset by setting the thermostat down for at least one minute before continuing.
25613-0-0309 Page 54 INTERMITTENT PILOT TROUBLESHOOTING (continued).
25613-0-0309 Page 55 INTERMITTENT PILOT TROUBLESHOOTING (continued) Green LED Status Codes Green LED Flash Code (X + Y) a Indicates Next System Action Recommended Service Action OFF No “Call for Hea.
25613-0-0309 Page 56 Functions • Flame powered system • Flame powered ame modulation • Electronics integrated into valve to provide thermostat, ame, and fan functions with RF commands • .
25613-0-0309 Page 57 FIRST USE OF TRANSMITTER Status Action Begin communication between transmitter and receiver/valve. Move LOCAL/REMOTE Switch to LOCAL position for at least two seconds; then move switch to the REMOTE position. T ransmit unique code.
25613-0-0309 Page 58 WIRING DIAGRAM WITH BLOWER Figure 72 RF WIRING DIAGRAM.
25613-0-0309 Page 59 1. ST OP! Read the safety information above. 2 . T urn off all electric power to the appliance (if applicable). 3. Lower louver front assembly . 4. Push in gas control knob slightly and turn clockwise to "OFF". NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly .
25613-0-0309 Page 60 Please Note It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for your gas replace to give off some odor the rst time it is burned.
25613-0-0309 Page 61 Glass Removal and Replacement (Figures 73 and 74) 1. Remove decorative front doors (where applicable) by opening and lifting straight up. 2. Remove decorative front by tilting lower portion forward to release ball catch and lifting front off mounting bracket.
25613-0-0309 Page 62 P AR TS VIEW 1 2 3 6 4 5 12 8 18 35 34 36 34 35 42 43 13 17 19 39 40 7 9 14 15 16 22 31 24 25 37 32 30 29 27 38 26 11 10 23 RF VA L V E ASSEMBL Y MILLIVOL T VA L V E ASSEMBL Y 33 .
25613-0-0309 Page 63 Use Only Manufacturer’ s Replacement Parts. Use of Any Other Parts Could Cause Injury Or Death. P AR TS LIST DVX36DP(31,71,91) Index No.
25613-0-0309 Page 64 P AR TS LIST DVX42DP(31,71,91) Use Only Manufacturer’ s Replacement Parts. Use of Any Other Parts Could Cause Injury Or Death. 30 P250 P250 P250 P245 P245 P245 Orice (LPG) 30.
25613-0-0309 Page 65 Attention: Install blower assembly before connecting gas inlet supply line Note: Junct ion box on righ t side of repla ce must be pre- wired at time of repla ce install ation for use with blower assembl y .
25613-0-0309 Page 66 110 VOLT AC JUNCTION BOX WHITE SPEED CONTROL FA N SWITCH GROUND BLACK FA N 1 FBB4 BLOWER ASSEMBL Y COMPLETE 2 R7649 F AN CONTROL 3 R4192 SPEED CONTROL KNOB 4 R4186 SPEED CONTROL F.
25613-0-0309 Page 67 ACCENT LAMP 12 VOLT SIDE 120 VOLT SIDE Y our Luxury Direct V ent Gas Fireplace comes equipped with our "Accent Lamp." The light has been pre-wired and is controlled from the Rheostat. If in the event the lamp or lens needs to be replaced, follow the instructions below: 1.
25613-0-0309 Page 68 DECORA TIVE ACCESSORIES ACCESSORIES The following accessory parts must be obtained from your Empire Comfort Systems dealer . If you need additional information contact your dealer .
25613-0-0309 Page 69 T o Order Parts Under W arranty , please contact your local Empire dealer . See the dealer locator at www .empirecomfort.com. T o provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
25613-0-0309 Page 70 36” (914mm) 6” (152mm) Web Site www .empirecomfort.com Empire Comfort Systems 918 Freeburg Avenue Belleville, Illinois 62220-2623 CLEARANCES T O COMBUSTIBLES The Studio Series.
25613-0-0309 Page 71 Web Site www .empirecomfort.com Empire Comfort Systems 918 Freeburg Avenue Belleville, Illinois 62220-2623 The Studio Series Direct V ent Gas Fireplace Heater MILLIVOL T ST ANDING.
25613-0-0309 Page 72 EMPIRE EMPIRE C o mfo r t Systems Empire Comfort Systems Inc. 918 Freeburg A ve. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Empire Comfort Systems DVX42DP91(N,P)-1 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Empire Comfort Systems DVX42DP91(N,P)-1 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Empire Comfort Systems DVX42DP91(N,P)-1, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Empire Comfort Systems DVX42DP91(N,P)-1 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Empire Comfort Systems DVX42DP91(N,P)-1, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Empire Comfort Systems DVX42DP91(N,P)-1.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Empire Comfort Systems DVX42DP91(N,P)-1. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Empire Comfort Systems DVX42DP91(N,P)-1 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.