Manuel d'utilisation / d'entretien du produit NGA2000 TO2 du fabricant Emerson
Aller à la page of 48
Instruction Manual 748374-F March 2003 http://www.processanalytic.com Model NGA2000 TO2 Trace Oxygen Analyzer.
Emerson Process Management Rosemount Analytical Inc. Process Analytic Division 1201 N. Main St. Orrville, OH 44667-0901 T (330) 682-9010 F (330) 684-4434 e-mail: gas.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Division of Emerson Process Management Contents i Model NGA2000 TO2 TABLE OF CONTENTS PREFACE...........................................................................................
Instruction Manual 748374-F March 2003 ii Contents Rosemount Anal ytical Inc. A Division of Emerson Process Management Model NGA2000 TO2 4-0 MAINTENANCE AND TROUBLESHOO TING ..................................................................... 4-1 4-1 Overview .
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Division of Emerson Process Management Contents iii Model NGA2000 TO2 LIST OF ILLUSTRATIONS Figure 1-1. Trace Oxygen Detect or Techno logy .............................................
Instruction Manual 748374-F March 2003 iv Contents Rosemount Anal ytical Inc. A Division of Emerson Process Management Model NGA2000 TO2.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Division of Emerson Process Management Preface P-1 Model NGA2000 TO2 PREFACE INTENDED USE STATEMENT The purpose of this manual is to .
Instruction Manual 748374-F March 2003 P-2 Preface Rosemount An alytical Inc. A Division of Emerson Process Management Model NGA2000 TO2 SAFETY SUMMARY If this equipment is used in a manner not specifie d in these instructions, prot ectiv e system s may be im- paired.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Division of Emerson Process Management Preface P-3 Model NGA2000 TO2 NOTICE Software compatibility is necessary for all NGA2000 compon ents in y our system to work together.
Instruction Manual 748374-F March 2003 P-4 Preface Rosemount An alytical Inc. A Division of Emerson Process Management Model NGA2000 TO2 GENERAL PRECAUTIONS FOR HANDLING AND STORING HIGH PRESSURE GAS .
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Division of Emerson Process Management Preface P-5 Model NGA2000 TO2 DOCUMENTATION The following NGA2000 Trace Oxygen Analyze r Mod ule instruction material s are available. Contact Cus- tomer Service Center (page 6-1 ).
Instruction Manual 748374-F March 2003 P-6 Preface Rosemount An alytical Inc. A Division of Emerson Process Management Model NGA2000 TO2 GLOSSARY OF TERMS Analyzer Module The module that contains all senso r/det ector component s for development of a Primary Variable signal; in- cludes all signal conditioni ng and temperature control circuitry.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Divisi on of Emerson Process Management Description and Specifications 1-1 Model NGA2000 TO2 SECTION 1 DESCRIPTION AND SPECIFICATIONS 1-1 OVERVIEW This manual describes the Trace Oxyge n (TO2) Analyzer Module of Rosemount Analytical's NGA2000 Series of gas analysis components.
Instruction Manual 748374-F March 2003 1-2 Description and Specifications Rosem ount Analytical Inc. A Divi sion of Emerson Process Management Model NGA2000 TO2 Figure 1-1.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Divisi on of Emerson Process Management Description and Specifications 1-3 Model NGA2000 TO2 Figure 1-2.
Instruction Manual 748374-F March 2003 1-4 Description and Specifications Rosem ount Analytical Inc. A Divi sion of Emerson Process Management Model NGA2000 TO2 1-5 SPECIFICATIONS a. General Measurement Species ................... Trace Oxygen Ranges .
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Division of Emerson Process Management Installation 2-1 Model NGA2000 TO2 SECTION 2 INSTALLATION 2-1 UNPACKIN G If the Trace Oxygen (TO2) Analyzer Mod ule is received as a separate unit, carefully examine the shipping carton and co ntents for signs of damage.
Instruction Manual 748374-F March 2003 2-2 Installation Rosemount Anal ytical Inc. A Division of Emerson Process Management Model NGA2000 TO2 with a clean, metallic diaphragm, two-stage regulator. A shutoff valve is recommended. Calibration Gases The TO2 module does not requi re routine zero calibration.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Division of Emerson Process Management Installation 2-3 Model NGA2000 TO2 Figure 2-2. Trace Oxygen Analy zer Outline and Mounting Dimensions 6.00 [152] 7.00 [178] 8.10 [206] 2.70 [68] 1.
Instruction Manual 748374-F March 2003 2-4 Installation Rosemount Anal ytical Inc. A Division of Emerson Process Management Model NGA2000 TO2 Sample Inlet 1/4" Tube Sample Exhaust 1/4" Tube Figure 2-3.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Division of Emerson Process Management Installation 2-5 Model NGA2000 TO2 Network Connections Power Connection Fuse Power Indicator Light Figure 2-4.
Instruction Manual 748374-F March 2003 2-6 Installation Rosemount Anal ytical Inc. A Division of Emerson Process Management Model NGA2000 TO2.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Division of Emerson Pr ocess Management Startup and Operation 3-1 Model NGA2000 TO2 SECTION 3 STARTUP AND OPERATION 3-1 OVERVIEW Prior to initial startup, the user should perform the leak test procedure outlined in Section 2.
Instruction Manual 748374-F March 2003 3-2 Startup and Operation Rosemount Analyt ical Inc. A Division of Emerson Process Management Model NGA2000 TO2 From the Run Mode display, press the MENUS softkey to gain access to the Main Menu. The Basic controls menu i s as follo ws: Figure 3-3.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Division of Emerson Pr ocess Management Startup and Operation 3-3 Model NGA2000 TO2 3-3 STARTUP PROCEDURE Establish sample or zero gas flow through the analyzer module at a nominal flow rate of 2 SCFH (1 l/min).
Instruction Manual 748374-F March 2003 3-4 Startup and Operation Rosemount Analyt ical Inc. A Division of Emerson Process Management Model NGA2000 TO2 Introduce zero gas in to the SAMPLE INLET, and, after a stable reading is reach ed, do the following: 1.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Division of Emerson Pr ocess Management Startup and Operation 3-5 Model NGA2000 TO2 3-8 ALARM INDICATI ON NGA analyzer modules co ntinuously monitor a number of internal parameters.
Instruction Manual 748374-F March 2003 3-6 Startup and Operation Rosemount Analyt ical Inc. A Division of Emerson Process Management Model NGA2000 TO2.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Divisi on of Emerson Process Management Maintenance and Troubleshooting 4-1 Model NGA2000 TO2 Sensor Cov er Indicat or, Elect rol y t.
Instruction Manual 748374-F March 2003 4-2 Maintenance and Troubleshooting Rosemount A nalytical Inc. A Division of Emerson Process Management Model NGA2000 TO2 a. Water Addition To add water: 1. Remove the top cover of t he analyzer module. 2. Unscrew the black sen sor cover.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Divi sion of Emerson Process Management Maintenance and Troubleshooting 4-3 Model NGA2000 TO2 Install replacement Sensor in reverse order. Check Sensor for leaks an d add electrolyte as described in Section 2-2a on pag e 2-1.
Instruction Manual 748374-F March 2003 4-4 Maintenance and Troubleshooting Rosemount A nalytical Inc. A Division of Emerson Process Management Model NGA2000 TO2 sensor is a partial pressure measuring device, an increase in sample pressure will cause an increase in reading.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Divi sion of Emerson Process Management Replacement Parts 5-1 Model NGA2000 TO2 SECTION 5 REPLACEMENT PARTS WARNING PARTS INTEGRITY Tampering with or unauthorized substi- tution of components may adversely af- fect safety of this product.
Instruction Manual 748374-F March 2003 5-2 Replacement Parts Rosemount Analytical Inc. A Divi sion of Emerson Process Management Model NGA2000 TO2.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Divi sion of Emerson Process Management Return of Material 6-1 Model NGA2000 TO2 SECTION 6 RETURN OF MATERIAL 6-1 RETURN OF MATERIAL If factory repair of defective equipment is re- quired, proceed as follows: 1.
Instruction Manual 748374-F March 2003 6-2 Return of Material Rosemount Analytical Inc. A Divi sion of Emerson Process Management Model NGA2000 TO2.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Divi sion of Emerson Process Management Appendix A. Menu Structure 7-1 Model NGA2000 TO2 SECTION 7 APPENDIX A. MENU STRUCTURE 7-1 NGA TO2 MENU STRU C TURE INTRODUCTION This Appendix contains a listing of the menu s belonging to the TO2 Analyzer Module.
Instruction Manual 748374-F March 2003 7-2 Appendix A. Menu Structure Rosemount Analytical Inc. A Divi sion of Emerson Process Management Model NGA2000 TO2 The Range Settings men u allows configuration of the upper and lower limit of the 4 ranges o n the Analyzer Module.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Divi sion of Emerson Process Management Appendix A. Menu Structure 7-3 Model NGA2000 TO2 From the Analyzer Diagnostics m enu, all ana- lyzer health diagnostic information can be ac- cessed.
Instruction Manual 748374-F March 2003 7-4 Appendix A. Menu Structure Rosemount Analytical Inc. A Divi sion of Emerson Process Management Model NGA2000 TO2 The Load Factory Calibra tion scre ens allow the user to enter the factory calibration data unique to the sensor in the Analyzer Module.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Divi sion of Emerson Process Management Appendix A. Menu Structure 7-5 Model NGA2000 TO2 Temperature Parameters… sele ct ion directs the user to the sensor temperature information. It is recommended that the user not co nd uct temperature calibration of the sensor in the field.
Instruction Manual 748374-F March 2003 7-6 Appendix A. Menu Structure Rosemount Analytical Inc. A Divi sion of Emerson Process Management Model NGA2000 TO2.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Divi sion of Emerson Process Man agement Appendix B. User Interface Help 8-1 Model NGA2000 TO2 SECTION 8 APPENDIX B. USER INTERFACE HELP This section provides a mean s of rapidl y finding any desired function or configuratio n factor in the menu system.
Instruction Manual 748374-F March 2003 8-2 Appendix B. User Interface Hel p Rosemount Analytical Inc. A Division of Emerson Process Management Model NGA2000 TO2 ITEM PATH NOTES Range number sel ec- ti.
Instruction Manual 748374-F March 2003 Rosemount Analytical Inc. A Divi sion of Emerson Process Management Index 9-1 Model NGA2000 TO2 SECTION 9 INDEX 2 24 V 5A DC power, 2-5 A alarm electrolyte, 4-1,.
Instruction Manual 748374-F March 2003 9-2 Index Rosemount Analytical Inc. A Divi sion of Emerson Process Management Model NGA2000 TO2 R Return Authorization, 6-1 S sample connections, 2-2 flow rate, .
WARRANTY Goods and part(s) (excluding consu mables) manufac tured by Seller are warrant ed to be free fro m defects in workman ship and material under normal use and se rvice for a period of twelve (12) months from the date of shipment by Seller. Consumable s, glass electrode s, membranes, liquid junctions, electrolyte, o-rings, etc.
Instruction Manual 748374-F March 2003 © Rosemount Analytical Inc. 2003 Emerson Process Management Rosemount Analytical Inc. Process Analytic Division 1201 N. Main St. Orrville, OH 44667-0901 T (330) 682-9010 F (330) 684-4434 E gas.csc@emersonprocess.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson NGA2000 TO2 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson NGA2000 TO2 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson NGA2000 TO2, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson NGA2000 TO2 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson NGA2000 TO2, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson NGA2000 TO2.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson NGA2000 TO2. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson NGA2000 TO2 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.