1 99 Series Rev . 3 / 99 USER MANUAL FOR THE METRO C199 AND FL199 SERIES INSULA TED HEA TED CABINETS Recommended Food Holding Guidelines Listed on pages 5 & 6.
1 I. INTRODUCTION A. IDENTIFYING YOUR CABINET Y our cabinet assembly has been shipped in two cartons. The first car ton contains the cabinet with module.
2 B. FEA TURES — ALL MODELS In order to utilize your new cabinet to its full potential, take a minute to identify the following features which have been provided for your convenience. • The module has been placed at the base of the cabinet for easy accessibility and efficient operation.
3 CVSN/-T/-H — Model V (adjustable) The Model V Slide Rack can be installed in either an inboard or outboar d position. Center spacing on slides can be either 3" or 4 1 / 2 ". Slides can be r emoved by lifting upward and sliding the rivet heads out of the keyhole slots.
4 It is not necessary at the end of the operating day to disrupt the TEMPERA TURE setting in order to turn the unit OFF . By switching the POWER switch to OFF , the unit is no longer operating. By switching the POWER switch to ON when resuming operations, the cabinet setting will be at the previous set point.
5 9. T o install the module, reverse step 8. When installing the module into the cabinet, the cord must be fed thr ough the opening in the cabinet back panel.
6 III. FOOD HOLDING GUIDELINES A. HM2000/HM15L W Recommended Food Holding Guidelines Food Product Covered/Uncovered T emperature Setting °F* Baked Fish Uncovered 175 Baked Potatoes Uncovered 180 Bisc.
7 I V . CLEANING INSTRUCTIONS CAUTION A T NO TIME SHOULD THE MODULE OR CABINET BE W ASHED OR FLOODED WITH W A TER OR LIQUID SOLUTION. NEVER STEAM CLEAN. SEVERE DAMAGE OR ELECTRICAL HAZARD COULD RESUL T . 1. T ur n off master switch. 2. Disconnect the unit from its power sour ce.
8 16 13 10 9 23 25 1 19 22 8 2 5 28 VI. REPLACEMENT P ARTS, PROCEDURES AND WIRING DIAGRAMS A. CABINET — ALL MODELS Refer to the Cabinet Replacement Parts Diagram on next page to identify the replacement parts.
9 CABINET REPLACEMENT P AR TS LIST ( 1 / 2 & 3 / 4 height cabinet parts not shown) Item No. Part No. Description 1 RPC199P-1102T T op Door 2 RPC199P-1102B Bottom Door 3 RPC199HP-1102 Door ( 1 / 2 .
10 B. MODULE Y our module has been designed to be user - servicable, assuming a basic knowledge of the operation of electrical devices. This section has been written to guide the user step by step, and in layman ’ s ter ms, through the dismantling and servicing of the module.
11 Holding Module Replacement Parts Diagram REPLACEMENT PARTS LIST Item No. Part No. Description 1 RPC13-017 Power Cord — 15 AMP (HM15L W only) 2 RPC13-083 Strain Relief — 15 AMP (HM15L W only) 3 .
12 HOLDING WIRING DIAGRAM VI. WIRING SCHEMA TICS.
13 FL2000 High Humidity Module Replacement Parts Diagram AIR DUCT 3 6 4 19 20 19 18 AIR INT AKE COVER 17 5 CONTROL P ANEL THERMOST A T BULB THERMOMETER SENSOR TOP P AN 9 10 DEFLECTOR PLA TE 11 12 16 C.
14 FL2000 HIGH HUMIDITY MODULE WIRING DIAGRAM WIRE NUT (TYP) BLACK 4 6 1 6 5 4 3 2 0 1 2 8 - + 6V DC OUTPUT POWER SUPPLY THERMOMETER TRANSFORMER 24V AC PERCENTAGE TIMER SWITCHING 110V AC 24V AC RELAY .
15 CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE CUSTOMER INFORMA TION 1. Which one of the following best describes your establishment? a. ❑ Full Service Restaurant b. ❑ Fast Food Restaurant c. ❑ Hotel/Motel d. ❑ Hospital/Nursing Home e. ❑ College/University f.
FOLD HERE — DO NOT DET ACH ST APLE HERE ST APLE HERE BUSINESS REPL Y MAIL FIRST -CLASS PERMIT NO. 121 WILKES-BARRE, PA NO POST AGE NECESSARY IF MAILED IN THE UNITED ST A TES POST AGE WILL BE PAID BY.
W arranty W ARRANTY , EXCLUSION OF W ARRANTIES AND LIMIT A TION OF LIABILITY . InterMetro Industries Cor poration (hereinafter ref erred to as “Seller”) warrants to the original purchaser that all products in its catalog, or custom products, delivered hereunder will be free from def ects in workmanship and mater ial.
InterMetro Industries Corporation North Washington Str eet, Wilkes-Barr e, P A 18705 For Product Information Call: 1-800-433-2232 Visit Our W eb Site: www .metro.com L01-386 Rev . A 03 / 03 Information and specifications are subject to change without notice.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson C199 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson C199 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson C199, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson C199 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson C199, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson C199.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson C199. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson C199 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.