Power Blower Operator's Manual MODEL PB-610 W ARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood for proper and safe operation.
2 T ABLE OF C ONTENTS Introduction .................................................................. 2 - The Operator's Manual .......................................... 2 Safety ..................................................................
3 P OWER B LOWER O PERA TOR ' S M ANUAL IMPORTANT The enclosed message provides information necessary for the protection of the unit. NOTE This enclosed message provides tips for use, care and maintenance of the unit.
4 Physical Condition Your judgment and physical dexterity may not be good: • if you are tired or sick, • if you are taking medication, • if you have taken alcohol or drugs. Operate unit only if you are physically and mentally well. Eye Protection Wear eye protection that meets ANSI Z87.
5 P OWER B LOWER O PERA TOR ' S M ANUAL Repetitive S tress Injuries It is believed that overusing the muscles and tendons of the fingers, hands, arms, and shoulders may cause soreness, swelling, numbness, weakness, and extreme pain in those areas.
6 Emission Control Label (located on Engine) (EXAMPLE ONLY, information on label varies by FAMILY). PRODUCT EMISSION DURABILITY The 300 hour emission durability compliance period is the time span sele.
7 P OWER B LOWER O PERA TOR ' S M ANUAL 1 2 3 4 5 6 7 8 10 11 12 9 13 14 Hot Decal (near muffler) General W arning Decal (located on top of blower housing) P/N 89016006361 P/N 89016009461 72 Category III dB(A) Measured at 50 ft. (15m) per ANSI B175.
8 1. AIR CLEANER - Contains replaceable air filter element. 2. SPARK PLUG - Provides spark to ignite fuel mixture. 3. SPARK ARRESTOR - CATALYTIC MUFFLER / MUFFLER - The muffler or catalytic muffler controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler.
9 P OWER B LOWER O PERA TOR ' S M ANUAL A SSEMBL Y W ARNING DANGER Never perform maintenance or assembly procedures with engine running or serious personal injury may result. INST ALL BLOWER PIPES / STICK HANDLE 1 . Assemble clamps (A) onto both ends of flexible pipe (B).
10 O PERA TION NOTICE: Use of unmixed, improperly mixed, or fuel older than 90 days, (stale fuel), may cause hard starting, poor performance, or severe engine damage and void the product warranty. Read and follow instructions in the Storage section of this manual.
11 P OWER B LOWER O PERA TOR ' S M ANUAL o i t a R 1 : 0 5 - x i M l i O o t l e u F . S . UC I R T E M S A GL I OS A GL I O s n o l l a G. z o . l Fr e t i L. c c 1 2 5 6 . 2 2 . 5 3 1 4 8 0 2 0 8 0 6 1 0 0 4 Mixing Instructions 1 . Fill an approved fuel container with half of the required amount of gasoline.
12 D 4. Recoil Starter Pull recoil starter handle (D) and engine should start. 5. Choke Move choke (B) to run ( ) position and if necessary, restart engine. NOTE If engine does not start after 5 pulls, repeat instructions 2-5. NOTE Allow engine to warm up before use.
13 P OWER B LOWER O PERA TOR ' S M ANUAL NOTE Never use a higher speed setting than necessary to perform a task. Remember, the higher the engine speed, the louder the blower noise. Minimize dust by using blower at lower speeds and by dampening material with water/mist when necessary.
14 M AINTENANCE Your ECHO unit is designed to provide many hours of trouble free service. Regular scheduled maintenance will help your unit achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take your unit to an ECHO Service Dealer for maintenance.
15 P OWER B LOWER O PERA TOR ' S M ANUAL W ARNING DANGER Allow the engine and muffler to completely cool before performing any maintenance activity.
16 SP ARK PLUG Level 1. Tools required: 3/4 in. Spark Plug deep socket, feeler gauge Parts Required: REPOWER TM Tune Up Kit P/N 90071 IMPORTANT Use only NGK BPM-8Y spark plug (BPMR-8Y in Canada) otherwise severe engine damage may occur. 1 . Remove spark plug and check for fouling, or worn and rounded center electrode.
17 P OWER B LOWER O PERA TOR ' S M ANUAL COOLING SYSTEMS CLEANING Level 2. Tools required: 25 - 50 mm (1 - 2 in.) Cleaning brush, cross head screwdriver Parts Required: None, if you are careful. IMPORTANT To maintain proper engine operating temperatures, cooling air must pass freely through the cylinder fin area.
18 A D C B E EXHAUST SYSTEM Spark Arrestor Screen Level 2. Tools required: Cross head screwdriver, soft metal brush Parts Required: Spark arrestor screen. Gaskets (3) IMPORTANT Carbon deposits in muffler will cause a drop in engine output and overheating.
19 P OWER B LOWER O PERA TOR ' S M ANUAL CARBURETOR ADJUSTMENT Engine Break-In New engines must be operated a minimum duration of two tanks of fuel break-in before carburetor adjustments can be made. During the break-in period your engine performance will increase and exhaust emissions will stabilize.
20 Initial Adjustment 1 . With engine off, turn HI speed screw (C) counterclockwise to stop. 2 . Turn LO speed screw (B) midway between stops. 3 . Turn idle screw (A) until tip of screw just touches throttle plate; then turn three (3) turns clockwise.
21 P OWER B LOWER O PERA TOR ' S M ANUAL T R A H C G N I T O O H S E L B U O R T m e l b o r Pk c e h Cs u t a t Se s u a Cy d e m e R - s k n a r c e n i g n E / d r a h s t r a t s t ' n s.
22 2 . Place the stop switch in the "STOP" position. 3 . Remove accumulation of grease, oil, dirt and debris from exterior of unit. 4 . Perform all periodic lubrication and services that are required.
23 P OWER B LOWER O PERA TOR ' S M ANUAL S PECIFICA TIONS MODEL ---------------------------------------------------------- PB-610 Length ------------------------------------------------------------ 325 mm (12.8 in.) Width ------------------------------------------------------------- 520 mm (20.
DEALER? Call 1-800-432-ECHO 1-800-432-3246 or www .echo-usa.com ECHO, INCORPORA TED 400 Oakwood Road Lake Zurich, IL 60047 www .echo-usa.com CONSUMER PRODUCT SUPPORT 1-800-673-1558 8:30 - 4:30 Mon - Fri C.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Echo PB-610 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Echo PB-610 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Echo PB-610, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Echo PB-610 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Echo PB-610, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Echo PB-610.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Echo PB-610. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Echo PB-610 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.