Manuel d'utilisation / d'entretien du produit 15560 du fabricant Drive Medical Design
Aller à la page of 18
1 Owner ’ s Assembly And Operating Manual Ultr a Light Plus, Semi Electric Bed Competitor Item # 15560.
2 REV3.1.23.14 1. Remove contents from carton. Assembl y Instr uctions 2. Placebothendsofthesleepsurfaceontheirsideandaligntheangewiththereceptacleasshown.
3 Assembl y Instr uctions Cont. 4. Securethesleepsurfacewiththecotterpinasshown. 5. Lockthecotterpinwiththeattachedclasp.
4 REV3.1.23.14 Assembl y Instr uctions Cont. 6. NOTE:Beforeinstallingmotor ,plughandpendantcableintomotorasshown 7.
5 Assembl y Instr uctions Cont. T her e ar e tw o methods for the installa tion of the motor Method A The motorisinstalledonthebedframewhentheframeisstanding on its side. Installation instructions can be found on pages 7-8.
6 REV3.1.23.14 Assembl y Instr uctions Cont. A2. Align the opening on the head end of the motorwiththeangeontheheadsectionof thebedandinserttheangeintothemotor compartment. Actuator Bar Flange A3.
7 A6. Once in place, replace the motor covers to secure the motor . A6. Oncethemotorisattached,laybedatandinstallheadandfootboards.Thereare2height adjustments on the head and foot board. Select the desired positions and hook the frame onto the foot board.
8 REV3.1.23.14 Assembl y Instr uctions Cont. End Method A Thechartbelowindicatestheheightadjustmentsastheyrelatetothetwoadjustmentoptions.
9 End Method A Method B Installation of the motor from underneath the frame B2. Repeat for the other side. Assembl y Instr uctions Cont. Deck Height Pins Leg Holes Upper Lower 1- High 1- Medium 1-Low B1.
10 REV3.1.23.14 Assembl y Instr uctions Cont. B4. Removethecoversfromthemotorandplaceunderthebedandalignedwiththeactuatorunderthehead section. There are labels on the motor that provide direction and placement in relation to the head section.
11 Assembl y Instr uctions Cont. B6. Once in place, replace the motor covers to secure the motor . End Method B.
12 REV3.1.23.14 Assembl y Instr uctions Cont. Oncethedesiredpositionisfound,turnthethumbscrewuntiltight. Adjustotherlegstothesameposition. 12. Adjustmenttwoisonthelegoftheheadandfootboard.
13 Assembl y Instr uctions Cont. Thechartbelowindicatestheheightadjustmentsastheyrelatetothetwoadjustmentoptions. *Rails cannot be used at this height. Deck Height (inches) Deck Height Pins Leg Hole Wheels 1 1* Lower Low No 13.
14 REV3.1.23.14 Assembl y Instr uctions Cont. 14. TheCompetitorbedcomeswithacasteraccessory(soldseparately ,model#15044SET).T oinstallthe casters,insertthestemofthecasterintothelegreceptacleasshown.
15 15. T oinstallbedrails,lifttheheadsectionandndtherailreceptaclelocatedontheframeofthebedasshown. Assembl y Instr uctions Cont. 16. Pullreceptacleoutwardandreturnheadsectiontotheatposition.
16 REV3.1.23.14 Assembl y Instr uctions Cont. 18. Insert the bed rail into the receptacle. Repeat for the other rail. NOTE: The competitor bed can be used with a free standing trapeze or a Drive Medical frame mounted trapeze (Item # 15560TRAPEZE). A trapeze cannot be mounted on the Competitor head board.
17 Driverecommendsthefollowingmaintenanceandcleaningproceduresbeconductedbetweenusers. ELECTRONICS • Checkallcontrolstomakesureallfunctionsworkproperly . • Foot control • Head control • Checkallcablesfordamagedorfrayedwires.
18 REV3.1.23.14 99 Seaview Boule v ar d P ort W ashington, NY 11050 Phone: 516-998-4 600 T oll F ree: 8 77 .224 . 09 46 F ax: 516. 998.460 1 ww w .driv emedical.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Drive Medical Design 15560 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Drive Medical Design 15560 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Drive Medical Design 15560, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Drive Medical Design 15560 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Drive Medical Design 15560, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Drive Medical Design 15560.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Drive Medical Design 15560. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Drive Medical Design 15560 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.