Manuel d'utilisation / d'entretien du produit K10 du fabricant Directed Electronics
Aller à la page of 16
NO TE: This product is intended for installation b y a prof essional installer only! Any attempt to install this product by an y person other than a trained prof essional may result in se v ere damage to a vehicle’ s electrical system and components.
3 table of contents primary harness (H1) wire connection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 primary har ness (H1) wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 primary harness (H1) wire connection guide primary harness (H1) wiring diagram The primar y harness supplied with this unit is the standard 12-pin harness used.
5 H1/2 WHITE (-) Parking Light Output This wire provides a (-) 200mA output to flash the parking lights. This is suitable for driving (-) light control wires in T oyota, Lexus, BMW , some Mitsubishi, some Mazda, etc. If the vehicle has a positive parking light circuit, a relay must be used to flash the parking lights.
6 H1/6 BLUE (-) 200 mA Second Unlock Output The H1/6 BLUE output is used for progressive unlock. A progressive unlock system unlocks the driver's door when the unlock (disarm) button is pressed and unlocks the passenger doors if the unlock (disarm) button is pressed again within 15 seconds after unlocking the driver's door .
7 H1/11 RED (+)12V constant power input Before connecting this wire, remove the supplied fuse. Connect to the positive batter y terminal or the constant 12V supply to the ignition switch. N N O O T T E E : : Always use a fuse within 12 inches of the point you obtain (+)12V .
8 door lock harness (H4), wire connection guide ___ ___ ___ peripheral plug-in harnesses LED, 2-pin WHITE plug The LED operates at (+) 2 volt DC and plugs into the two-pin WHITE port. Make sure the LED wires are not shorted to ground as the LED will be damaged.
9 Pro Security Pr ogrammer interface, 3-pin port The BLACK three-pin port is provided for pr ogramming of the unit. When using the P ro Security P rogrammer , it is possible to configure any and all of the programmable functions. F or more information please refer to the guide packaged with the programmer .
10 3. T ransmit. The transmitter is used to select the desired setting. As shipped, the unit is configured to the LED ON settings. These are the default settings. Pressing the lock button will set it to the LED ON setting. The LED will light solid (stop flashing) to indi- cate the setting.
11 system features menus feature descriptions 1 ACTIVE/P ASSIVE ARMING: When active arming is selected, the starter kill will ar m (if connected) only when the transmitter is used. When set to passive arming, the starter kill will ar m (if connected) 30 seconds after the ignition key is turned off.
12 8 DOUBLE PULSE UNLOCK OFF/ON: Some vehicles require two pulses on a single wire to unlock the doors. When the double pulse unlock feature is turned on, the BLUE H2/C wire will supply two nega- tive pulses instead of a single pulse. At the same time, the GREEN H2/A wire will supply two positive pulses instead of a single pulse.
13 Channels #4-6: Channels 4 through 6 are used to assign the arm, disarm and panic functions to sep- arate buttons on the remote control. T eaching a button to Channel 4 erases all information about that remote from memor y . Any auxiliar y functions that are desired will have to be reprogrammed.
14 remote configurations The transmitters can be programmed with the standard or single button arm/disarm configurations by using the Auto Learn functions in the Remote Coding. standard configuration A remote that uses the standard configuration operates similarly to many factor y keyless entry remotes.
15 power-up Power-up ensures that the when the system is powered up it will return to the same state it was in when power is disconnected. For a full description of power-up refer to the owner's manual.
16 3-Pin 2-Wire Door Lock Harness Override Switch Pro Secur ity Programmer ® ™ wiring quick reference guide.
Get Started Get Protected Ungo Pro Security 661 W . Redondo Beach Blvd. Gardena, Ca. 90247 800-GO-CLARION © 2003 Directed Electroni cs, Inc . - All rights r eserved GK10 11-03.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Directed Electronics K10 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Directed Electronics K10 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Directed Electronics K10, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Directed Electronics K10 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Directed Electronics K10, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Directed Electronics K10.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Directed Electronics K10. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Directed Electronics K10 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.