1 INST ALLA TION and OPERA TING INSTRUCTIONS Brine-to-W ater Heat Pump for Indoor Installation SI 1 1KS SI 14KS SI 7KS SI 9KS CE Order No.: 452231.67.01 FD 8504.
2 CONTENTS 1 PLEASE READ IMMEDIA TEL Y 3 1.1 Important Information 1.2 Legal Provisions and Directives 1.3 Energy-Efficient Use of the Heat Pump 2 PURPOSE OF THE HEA T PUMP 4 2.1 Application 2.2 Principle of Operation 3 BASELINE UNIT 4 4 ACCESSORIES 5 4.
3 READ IMMEDIA TEL Y 1.1 Important Information The heat pump is not secured to the wooden pallet. The heat pump must not be tilted more than max. 45° (in either direction). Do not lift unit by the holes in the panel assemblies! In the case of large-capacity heating circuits, the installed expansion vessel (24 litres, 1.
4 3 2 PURPOSE OF HEA T PUMP BASELINE UNIT PURPOSE OF THE HEA T PUMP 2.1 Application The brine-to-water heat pump is designed for use in existing or newly built heating systems. Brine is used as the heat carrier in the heat source system. Ground coils, ground collectors or similar systems can be used as the heat source.
5 5 4 ACCESSORIES 4.1 Brine Manifold The brine manifold ties the individual collector loops of the heat source system into a single main line which is connected to the heat pump. Integrated ball valves allow individual brine circuits to be shut off for venting purposes.
6 MOUNTING 7.1 General The following connections need to be established on the heat pump: - supply/return flow of the brine system - supply/return flow of the space heating and water heating system - .
7 CAUTION! MOUNTING pump installations where a power failure cannot readily be detected (e.g. holiday houses), the heating circuit must contain a suitable antifreeze product. The integrated expansion vessel has a capacity of 24 litres.This capacity is appropriate for buildings with a heated living space floor area of up to 200 m 2 .
8 9 COMMISSIONING CARE/CLEANING COMMISSIONING 8.1 General T o ensure proper commissioning it should be carried out by an after-sales service authorised by the manufacturer . Only then can an extended warranty period of 3 years in total be granted (cf.
9 10 CAUTION! 11 According to current knowledge, we recommend cleaning with a 5% phosphoric acid solution or , in the case that cleaning needs to be performed more frequently , with a 5% formic acid solution. In either case, the cleaning fluid should be at room temperature.
10 APPENDIX 12 12.1 DIMENSIONED DRAW- ING 1 1 12. 2 EQUIPMENT D A T A 12 12 .3 SCHEMA TICS 12.3.1 Characteristics .. 7KS 1 3 12.3.2 Characteristics .. 9KS 1 4 12.3.3 Characteristics .. 1 1KS 1 5 12.3.4 Characteristics .. 14KS 1 6 12. 4 WIRING DIAGRAMS 12.
11 APPENDIX: 12.1 DIMENSIONED DRAWING Dimensioned Drawing 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder Heating circuit pressure gauge Brine circuit pressure gau.
12 APPENDIX: 12.2 EQUIPMENT D A T A Equipment Data EQUIPMENT DATA for Brine-to-Water Heat Pumps for Heating 1 TYPE AND COMMERCIAL DESCRIPTION ..7KS ..9KS ..11KS ..14KS 2 MODEL 2.1 Type compact compact compact compact 2.2 Enclosure type acc. to EN 60 529 IP 20 IP 20 IP 20 IP 20 2.
13 12.3.1 Characteristics .. 7KS APPENDIX: 12.3 SCHEMA TICS 0 2 4 6 8 10 12 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 0,5 1 1,5 2 2,5 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl.
14 12.3.2 Characteristics .. 9KS APPENDIX: 12.3 SCHEMA TICS 0 2 4 6 8 10 12 14 16 18 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 0,5 1 1,5 2 2,5 3 3,5 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl.
15 12.3.3 Characteristics .. 1 1KS APPENDIX: 12.3 SCHEMA TICS 0 2 4 6 8 10 12 14 16 18 20 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 0,5 1 1,5 2 2,5 3 3,5 4 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl.
16 12.3.4 Characteristics .. 14KS APPENDIX: 12.3 SCHEMA TICS 0 5 10 15 20 25 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 1 2 3 4 5 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl.
17 12.4.1 Control .. 7KS to .. 14KS APPENDIX: 12.4 WIRING DIAGRAMS Mains power supply.
18 12.4.2 Load .. 7KS to .. 14KS APPENDIX: 12.4 WIRING DIAGRAMS Mains power supply Soft starter not available in brine-to-water unit 7KS.
19 Mains power supply Mains power supply or Utility company disable contactor Contact open = HP disabled The function of the back-up heater can be selected 2 nd disable input Contact open = HP disabled factory-wired to be field-connected, if required 12.
20 12.4.4 Legend .. 7KS to .. 14KS APPENDIX: 12.4 WIRING DIAGRAMS A 1 Wire jumper , must be inserted if no utility company disable contactor is required A2 Wire jumper , must be removed if 2nd disable.
21 Hydraulic Block Diagram APPENDIX: 12.5 HYDRAULIC BLOCK DIAGRAM Check valve Shut-off valve Overflow valve Safety assembly Circulating pump Expansion vessel Thermostat/manual valve Shut-off valve wit.
22 APPENDIX: 12.6 EC DECLARA TION OF CONFORMITY EC Declaration of Conformity Declaration of Conformity The undersigned Glen Dimplex Deutschland GmbH Division Dimplex Am Goldenen Feld 18 D-95326 Kulmba.
23 Notes.
24 Glen Dimplex Deutschland GmbH Subject to technical modifications Division Dimplex Fax +49 92 21/709-589 Am Goldenen Feld 18 ww w .dimplex.de D-95326 Kulmbach.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Dimplex S1 7KS c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Dimplex S1 7KS - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Dimplex S1 7KS, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Dimplex S1 7KS va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Dimplex S1 7KS, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Dimplex S1 7KS.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Dimplex S1 7KS. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Dimplex S1 7KS ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.