Save this manual for future reference. BLUE FLAME VENT -FREE NA TURAL GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL 10,000 Btu/Hr Thermostatically- Controlled Models VN1000BT A WARNING: If the information in this manual is not followed exactly, a fire or explosion may result caus- ing property damage, personal injury, or loss of life.
2 104265 BLUE FLAME 10,000 BTU NA TURAL GAS HEA TER ® Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nau- sea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced.
3 104265 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1 also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
4 104265 BLUE FLAME 10,000 BTU NA TURAL GAS HEA TER ® PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1.
5 104265 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
6 104265 BLUE FLAME 10,000 BTU NA TURAL GAS HEA TER ® Figure 2 - Ventilation Air from Inside Building Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12&.
7 104265 OWNER’S MANUAL Figure 5 - Mounting Screw Locations Mounting Screw Locations 8 7 / 8 " Minimum To Maintain 6" Clearance From Wall 7 3 / 4 " 20 1 / 4 " Minimum To Maintain 3" Clearance From Floor FLOOR JOINING WALL INSTALLING HEATER TO WALL Marking Screw Locations 1.
8 104265 BLUE FLAME 10,000 BTU NA TURAL GAS HEA TER ® Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack- age is provided with heater. Attaching To Wall Stud Method For attaching mounting screw to wall stud 1.
9 104265 OWNER’S MANUAL * A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessory , page 18.
10 104265 BLUE FLAME 10,000 BTU NA TURAL GAS HEA TER ® CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak.
11 104265 OWNER’S MANUAL TO TURN OFF GAS TO APPLIANCE 1. Remove fr ont panel (see Figure 10, page 8). 2. Follow steps 1 thr ough 5 under Light- ing Instructions . 3. With contr ol knob pr essed in, str ike match. Hold match to pilot until pi- lot lights.
12 104265 BLUE FLAME 10,000 BTU NA TURAL GAS HEA TER ® INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 17 shows a correct pilot flame pat- tern. Figure 18 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple.
13 104265 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. POSSIBLE CAUSE 1. Ignitor electrode positioned wrong 2. Ignitor electrode broken 3. Ignitor electrode not connected to igni- tor cable 4.
14 104265 BLUE FLAME 10,000 BTU NA TURAL GAS HEA TER ® TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during comb.
15 104265 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
16 104265 BLUE FLAME 10,000 BTU NA TURAL GAS HEA TER ® 12-2 12-1 ODS/PILOT ILLUSTRA TED PA R T S BREAKDOWN VN1000BTA 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 21 22 24 14 20 23 19.
17 104265 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.
18 104265 BLUE FLAME 10,000 BTU NA TURAL GAS HEA TER ® You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190. You can also visit DESA International’s technical service web site at www.
19 104265 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa VN1000BTA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa VN1000BTA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa VN1000BTA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa VN1000BTA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa VN1000BTA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa VN1000BTA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa VN1000BTA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa VN1000BTA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.