Sav e this manual for future reference. For more information, visit www .desatech.com MODELS M36(B,H), M42(B ,H), VM36(B,H) AND VM42(B ,H) NA TURAL GAS MODELS M36P(B,H), M42P(B ,H), VM36P(B,H) AND VM4.
www .desatech.com 108795-01N 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency or the gas supplier .
www .desatech.com 108795-01N 3 SAFETY INFORMA TION W ARNING: This product c o n t a i n s a n d / o r g e n e r a t e s chemicals known to the State of California to cause cancer or birth defects or other reproduc- tive harm.
www .desatech.com 108795-01N 4 11. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. Do not run fire- place where these are used or stored. Do not place items such as clothing or decorations on or around fireplace.
www .desatech.com 108795-01N 5 W ARN ING: Inst alla tion of this appliance should be done by a qualified service person well trained in the installation of such appliances. Y ou will also need a building permit from your local Building and Safety Commissioner before installing this appliance; otherwise your insurance co.
www .desatech.com 108795-01N 6 Model 36 Model 42 Mo del 3 6 Mo de l 42 Mo del 3 6 Model 42 A 29" 36" I 40 1 / 4 " 44 1 / 4 " Q 13 7 / 8 " 14" B 5/8" 5/8" J 21&q.
www .desatech.com 108795-01N 7 PRE-INST ALLA TION PREP ARA TION CLEARANCES Minimum clearances to combustibles are: • Back and Sides of Outer Surround . . . 0" min. • Drywall to Sides of Front Face (Nailing Flanges) . . . . . . . . . . . . . .
www .desatech.com 108795-01N 8 PRE-INST ALLA TION PREP ARA TION Continued FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering.
www .desatech.com 108795-01N 9 INST ALLING TRANSITION PIPE AND ST ARTER COLLAR The transition pipe and starter collar shown in Figu re 9 are suppli ed with the firep lace , una ttac hed and read y for ins tal lat ion . Rem ove the star ter col lar and set asi de.
www .desatech.com 108795-01N 10 Maintain Listed Clearance 12' Min. 12' Min. 45 45 6' 8' 12' Min. 60 45 Position Firestop Position Firestop Position Firestop Listed V ent Cap L.
www .desatech.com 108795-01N 1 1 CHECKING FOR PROPER VENTING After completing and checking the electrical, gas and vent connections, follow the lighting instructions and allow the main burner to run for approximately 5 minutes.
www .desatech.com 108795-01N 12 OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL INST ALLA TION Note: If using optional wireless hand-held remote control, the wall switch is no longer operational.
www .desatech.com 108795-01N 13 GAS LINE HOOK-UP W ARNING: Gas line hookup should be done by your gas supplier or a qualified service person. W ARNING: Before you pro- cee d, m ake sur e yo ur gas su pply is OFF . A manual shutof f valve has been included in the applianceʼ s gas supply system.
www .desatech.com 108795-01N 14 P I L O T ON OFF IN OUT Figure 21 - Connecting Flexible Gas Line to Millivolt V alve Gas Shutoff V alve Flexible Gas Line Do NOT Kink 1/2" NPT Incoming Gas Line No.
www .desatech.com 108795-01N 15 0.5" 0.5" Figure 24 - Pan and Ember Material Clearances Grate Burner Pan Pan and Ember Material INST ALLA TION Continued LOG PLACEMENT FOR M36, M36P , VM36 AND VM36P MODELS 1. Pla ce small front rig ht log (log 1) on right front of grate as shown in Figure 25.
www .desatech.com 108795-01N 16 INST ALLA TION Continued LOG PLACEMENT FOR M42, M42P , VM42 AND VM42P MODELS 1. Place lar ge back log (log 1) onto grate making sure notches rest over grate (see Figure 29).
www .desatech.com 108795-01N 17 INST ALLA TION Continued COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of the fireplace only . The vent can be installed through any outside wall a minimum of three feet below fireplace termination cap.
www .desatech.com 108795-01N 18 6. Repeat the process for the opposite door assembly . 7. T o adjust the doors, slide them partially open. Using a screwdriver , loosen the hold-down screws in the spring clip (see Figure 36) and pivot plate. 8. Close both doors until evenly joined at the middle and note the gap at the outer edges of the face.
www .desatech.com 108795-01N 19 OPERA TING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not fol- low these instructions exactly , a fire or explosion may result causing property damage, per- sonal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
www .desatech.com 108795-01N 20 TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel.
www .desatech.com 108795-01N 21 INSPECTING B URNERS Continued BURNER FLAME P A TTERN Burn er flames will be ste ady; not liftin g or floati ng. Flames should go up through the middle of logset. Flames should not "spill" to the edges of the pan or sides of the logset.
www .desatech.com 108795-01N 22 WIRING DIAGRAM DO NOT CONNECT RED REPLACE F ACTOR Y WIRING WITH 105°C EQUIV ALENT OR HIGHER RA TING THERMOST A T WIRE 18 GA. RED/WHITE EXTERNAL WIRING USE ONL Y CLASS 2 N.C.SW (VENT SAFETY SHUTOFF SWITCH) WHITE TH/TP TP TH WA LL SWITCH (SUPPLIED) MANUA L DAMPER SWITC H N.
www .desatech.com 108795-01N 23 TROUBLESHOO TING Note: Before troubleshoot ing the system, make sure the gas shutof f valve is ON. The two most common causes of a malfunctioning gas appliance are: 1.
www .desatech.com 108795-01N 24 TROUBLESHOO TING Continued OBSERVED PROBLEM Pilot goes out when wall switch is ON Spark ignitor will not light pilot after repeated triggering of red button Fireplace produces a clicking/ ticking noise just after burner is lit or shut off POSSIBLE CAUSE 1.
www .desatech.com 108795-01N 25 TROUBLESHOO TING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone.
www .desatech.com 108795-01N 26 ILL USTRA TED P ARTS BREAKDOWN MODELS M36(B,H), M36P(B,H), M42(B,H), M42P(B,H), VM36(B,H), VM36P(B,H), VM42(B,H) AND VM42P(B,H) 51 21 3 25 2 1 10 1 1 6 57 57 22 50 18 9.
www .desatech.com 108795-01N 27 P ARTS LIST This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual.
www .desatech.com 108795-01N 28 KEY NO. M3 6(B ,H ) VM 36( B, H) M4 2(B ,H ) VM 42( B, H) D ESC RIP TI ON QTY 12 106658-02 107812-02 Left Refractory , Std. Brick (M36B/M42B) 1 108164-02 108169-02 Left Refractory , Herringbone (M36H/M42H) 1 106658-01 107812-01 Left Refractory , Std.
www .desatech.com 108795-01N 29 ILL USTRA TED P ARTS BREAKDOWN LOGSETS FOR MODELS M36(B,H), M36P(B,H), VM36(B,H) AND VM36P(B,H) KEY NO. P ART NUMBER DESCRIPTION QTY .
www .desatech.com 108795-01N 30 KEY NO. P ART NUMBER DESCRIPTION QTY . - 107999-02 Log Set 1 901098-02 Rear Log 1 2A 108723-01 Left Front Log - 1 1" 1 2B 108839-01 Right Front Log - 15 3 / 4 &quo.
www .desatech.com 108795-01N 31 ACCESSORIES NOTICE: All accessories may not be available for all fireplace models. Purchase these firebox accessories from your local dealer . If they can not supply these accessories, call DESA ʼ s Sales Department at 1-866-672-6040 for information.
LIMITED WARRANTY VENT -FREE FIREBO X DESA warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa VM42P c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa VM42P - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa VM42P, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa VM42P va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa VM42P, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa VM42P.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa VM42P. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa VM42P ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.