Manuel d'utilisation / d'entretien du produit VGL24NRA du fabricant Desa
Aller à la page of 32
Sav e this manual for future reference. For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- lowed exactly , a fire or explosion may result causing property damage, personal injury , or loss of life.
www .desatech.com 1 12882-01B 2 W ARNING: Improper installation, adjustment, altera- tion, service, or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency , or the gas supplier .
www .desatech.com 1 12882-01B 3 SAFETY INFORMA TION WAR NING : Th is pr odu ct co n- ta ins an d/o r g ene rat es che mic als kno wn to the Stat e of Cali for nia to cau se can cer or birt h defe cts , or oth er rep rod uct ive ha rm.
www .desatech.com 1 12882-01B 4 SAFETY INFORMA TION Continued 1. This ap plia nce is only for us e wi th t he type of ga s indi ca ted on the rat in g plat e. This app lian ce is n ot conv erti ble for use wit h ot her gas es. 2. Do not place propane/LP supply tank(s) in - side any structure.
www .desatech.com 1 12882-01B 5 PRODUCT IDENTIFICA TION Figure 1 - V ent-Free Gas Log Heater Optional Remote Control LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the lat - est edition of The National Fuel Gas Code, ANSI Z223/NFP A 54*.
www .desatech.com 1 12882-01B 6 AIR FOR COMB USTION AND VENTILA TION WAR NING: T his he ater sh all not be installed in a confined space or unusually tight con - struction unless provisions are prov ided f or a dequa te c ombus - tion and ventilation air.
www .desatech.com 1 12882-01B 7 Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2,560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
www .desatech.com 1 12882-01B 8 Figure 3 - V entilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic AIR FOR COMB USTION AND VENTILA TIOIN Continued V entilation Air From Outdoors Prov ide extra fresh air by using ventilat ion grills or ducts.
www .desatech.com 1 12882-01B 9 CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater . Installing heater next to vinyl or cloth wall coverings o.
www .desatech.com 1 12882-01B 10 Minimum Noncombustible Material Clearances If Not Using Mantel Note: I f u si ng a m an te l, p ro ce ed t o I f Us in g Mantel. If not using a mantel, follow the informa- tion below . Yo u mu st ha ve no nc om bu s ti bl e m at er i al (s ) a bo ve th e fir ep la ce o pe ni ng .
www .desatech.com 1 12882-01B 1 1 NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following: • operate the logs only with the flue damper open • raise the mantel to an acceptable height • remove the mantel.
www .desatech.com 1 12882-01B 12 INST ALLA TION Continued FLOOR CLEARANCES A. If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).
www .desatech.com 1 12882-01B 13 INST ALLING HEA TER BASE ASSEMBL Y CAUTI ON: Do not remove the da ta pla tes att ac hed to the hea ter base assembly . The data plates contain important warranty and safety information. W ARNING: Y ou must secure this heater to fireplace floor .
www .desatech.com 1 12882-01B 14 INST ALLA TION Continued CONNECTING TO GAS SUPPL Y W ARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator . W ARNING: A qualified ser- vic e per son must conn ect heat er to gas supply .
www .desatech.com 1 12882-01B 15 CHECKING GAS CONNECTIONS W AR NIN G: T est all gas pip ing and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once. WA RN IN G: Ne ve r u s e an op en fl a m e to c he ck f or a le ak .
www .desatech.com 1 12882-01B 16 3. Chec k al l joi nts from pro pane /LP supp ly ta nk to equipm ent shuto ff valve for prop ane/ LP gas (se e Figur e 16) or fro m gas meter to equi pmen t shut off valve for natur al gas (se e Figu re 17). Appl y noncor rosi ve leak detec tion fluid to gas join ts.
www .desatech.com 1 12882-01B 17 INST ALLA TION Continued Figure 21 - Connecting Wires Control V alve White Wire From Receiver Red Wire From Receiver 8. Install remote receiver into receiver bracket using pads and push button clips provided with receiver (see Figure 20).
www .desatech.com 1 12882-01B 18 INST ALLING LOGS WA RN ING : Fai lur e to po sit ion t h e p a r t s i n ac co r d a n ce w it h t h e se di ag ra ms or fai lu re to use onl y pa rt s s pe ci fic al ly ap pr ov ed wi th th is he at er may r es ul t in pro pe rt y da ma ge o r pe rs on al i nj ur y.
www .desatech.com 1 12882-01B 19 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not fol- low these instructions exactly , a fire or explosion may result causing property damage, per - sonal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
www .desatech.com 1 12882-01B 20 Figure 20 - Pilot Ignitor Electrode Pilot Burner Ignitor Electrode Pilot Burner Propane/LP Gas Natural Gas TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. T urn control knob clockwise to the OFF position. 2a. Set selector switch in the OFF position.
www .desatech.com 1 12882-01B 21 OPERA TING HEA TER Continued OPTIONAL HAND-HELD REMOTE OPERA TION Note: All remote control accessories must be purchased separately (see Accessories, pag es 29). Follow instructions included with the re - mote control.
www .desatech.com 1 12882-01B 22 Figure 34 - Incorrect Pilot Flame Pattern Figure 33 - Correct Pilot Flame Pattern Pilot Burner Propane/LP Gas Natural Gas Thermocouple OPERA TING HEA TER Continued Pilot Burner Thermocouple Propane/LP Gas Natural Gas MAIN BURNER Periodically inspect all burner flame holes with the heater running.
www .desatech.com 1 12882-01B 23 CLEANING AND MAINTENANCE W ARNING: T urn off heater and let cool before cleaning. C AUTI ON: Yo u mus t kee p co nt ro l are as, bu rn er , and cir cu - la ti ng air pa ss ag ew ay s of hea te r clean. Inspect thes e areas of heat er b efore eac h us e.
www .desatech.com 1 12882-01B 24 TROUBLESHOO TING W ARNING: T urn off heater and let cool before servicing. Only a qualified service person should service and repair heater . CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
www .desatech.com 1 12882-01B 25 OBSERVED PROBLEM ODS/pilot lights but flame goes out when control knob is re - leased One or both burners do not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during com - bustion Sligh t s moke or od or during initial operation TROUBLESHOO TING Continued POSSIBLE CAUSE 1 .
www .desatech.com 1 12882-01B 26 TROUBLESHOO TING Continued OBSERVED PROBLEM Moisture/condensation noticed on windows Heater produc es a whistling noise when burner is lit White powder residue forming within burner box or on adjacent walls or furniture Remote does not function POSSIBLE CAUSE 1.
www .desatech.com 1 12882-01B 27 W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’s phone.
www .desatech.com 1 12882-01B 28 WIRING DIAGRAM Receiver Black On Off Remote Red Red White Thermopile Gas Control TPTH TH TPTH TP SERVICE HINTS When Gas Pressure Is T oo Low • pilot will not stay li.
www .desatech.com 1 12882-01B 29 ACCESSORIES Purchase these fireplace accessories from your lo- cal dealer . If they can not supply these accessories call DESA Heating Productsʼ Sales Department at 1-866-672-6040 for referral information. Y ou can also write to the address listed on the back page of this manual.
www .desatech.com 1 12882-01B 30 ILL USTRA TED P ARTS BREAKDOWN MODELS VGL18PRA, VGL18NRA VGL24PRA, VGL24NRA VGL30PRA, VGL30NRA 15 27 19 16 23 12 5 20 21 6 3 7 9 14 8 1 1 10 19 17 1 22 31 23 10 4 22 2.
www .desatech.com 1 12882-01B 31 P ARTS LIST This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual. P ART NUMBER KEY VGL18PRA VGL24PRA VGL30PRA NO.
112882 01 Model __________________________________ Serial No. _______________________________ Date Purchased __________________________ 2701 Industrial Drive P .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa VGL24NRA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa VGL24NRA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa VGL24NRA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa VGL24NRA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa VGL24NRA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa VGL24NRA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa VGL24NRA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa VGL24NRA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.