UNVENTED (VENT -FREE) NA TURAL GAS LOG HEA TER ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE OWNER’S OPERA TION AND INST ALLA TION MANUAL Save this manual for future reference. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER 1. This appliance is only for use with the type of gas indicated on the rating plate.
3 105070 OWNERS MANUAL PRODUCT IDENTIFICA TION Figure 1 - Ember Master Left Front Log Control Knob Rear Log Base Assembly Front Burner Piezo Ignitor Rear Burner Crossover Log Bottom Middle Log Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.
4 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Confined and Unconfined Space The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.
5 105070 OWNERS MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
6 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
7 105070 OWNERS MANUAL MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log Size 18", 24", 30" Side Wall 16" Ceiling 42" Floor 5" INSTALLATION AND CLEARANCES (Vent-Free Operation Only) WARNING: Maintain the mini- mum clearances.
8 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Noncombustible Requirements for Material Distance (A) Safe Installation 12" or more Noncombustible material OK. Between 8" and 12" 24" and 30" Models: Install fireplace hood accessory (HDABK or HDABR, see Accessories , page 22).
9 105070 OWNERS MANUAL 14" Min. Combustible Material Non-Combustible Material Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level Hearth 5" Min. Combustible Material Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring FLOOR CLEARANCES A.
10 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.
11 105070 OWNERS MANUAL 10. Attach mounting brackets to fireplace floor using masonry screws (in hard- ware package). 1 1 . Reattach heater base to mounting brackets.
12 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. WARNING: Test all gas pip- ing and connections for leaks after installing or servicing.
13 105070 OWNERS MANUAL INST ALLA TION Continued WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury. INSTALLING LOGS Each log is marked with a number.
14 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Figure 22 - Pilot Thermocouple Ignitor Electrode Pilot Burner 4. W ait fi ve (5) minutes to clear out any gas. Then smell f or gas, including near the floor . If you smell gas, STOP! F ollow “B” in the safety in- formation, column 1.
15 105070 OWNERS MANUAL TO TURN OFF GAS TO APPLIANCE WARNING: Do not operate heater between locked positions. CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve. The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained.
16 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER SPECIFICA TIONS 18" Variable 24" Variable 30" Variable Manually- Manually- Manually- Controlled Contro.
17 105070 OWNERS MANUAL TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
18 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER OBSERVED PROBLEM One or both burners do not light after ODS/ pilot is lit Delayed ignition of one or both burners Bur.
19 105070 OWNERS MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
20 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER ILLUSTRA TED PA R T S BREAKDOWN VARIABLE MANUALLY- CONTROLLED MODELS VFN18MV VFN24MV VFN30MV 17 19 18 25 24 20 20 26 .
21 105070 OWNERS MANUAL P ARTS LIST VARIABLE MANUALLY- CONTROLLED MODELS VFN18MV VFN24MV VFN30MV This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual.
22 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product.
23 105070 OWNERS MANUAL NOTES _______________________________________________________________________________________________ __________________________________________________________________________.
LIMITED WARRANTY VENT-FREE NATURAL GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa VFN24MV VFN30MV c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa VFN24MV VFN30MV - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa VFN24MV VFN30MV, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa VFN24MV VFN30MV va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa VFN24MV VFN30MV, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa VFN24MV VFN30MV.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa VFN24MV VFN30MV. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa VFN24MV VFN30MV ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.