FR
Desa logo
Notice d'utilisation officielle

Desa UKC70ET

56 pages·2.8 MB·Radiateur électrique·PDF·ENDEITNLJA
Desa UKC70ET
Table des matières 18 sections Safety Information · Unpacking · Product Identification · Fuels · … AfficherMasquer
Page 1 of the Desa UKC70ET user manual — TABLE OF CONTENTS
Page 1 · cliquer pour agrandir
Page 1

CANADIAN PORTABLE FORCED AIR HEATERS

OWNER’S MANUAL

MODELSBC40, RC40, BC55CT, RC55CT, UKC55CT, BC70ET, RC70ET, UKC70ET, BC115DT, RC115DT, UKC115DT, BC165DT,

RC165DT AND UKC165DT

HEATER SIZES: 40/55/70/115/165,000 BTU/HR MODELS

H.S.I. SERIES

TABLE OF CONTENTS

Safety Information 2 Unpacking 3 Product Identification 3 Fuels 4 Ventilation 4 Theory of Operation 4 Assembly 5 Operation 6 Operation With Portable Generator 7

Storing, Transporting or Shipping 7 Preventative Maintenance Schedule 8 Troubleshooting 8 Service Procedures 10 Specifications 15 Illustrated Parts Breakdown and Parts List 16 Wiring Diagrams 25 Accessories 26 Warranty and Repair Service Back Cover

Fill In For Your Records

Model No (Located on side panel)

Serial No (Located on fuel tank)

Date of Purchase_____________________

Save this manual for future reference. For more information, visit www.desatech.com

Page 2 of the Desa UKC70ET user manual — DANGER: Carbon monoxide poisoning may lead to death!
Page 2 · cliquer pour agrandir
Page 2

SAFETY INFORMATION

d) During fueling, all fuel lines and fuel-line

connections shall be inspected for leaks. Any leaks shall be repaired prior to returning the heater to service. e) At no time shall more than one dayʼs supply

of heater fuel be stored inside a building in the vicinity of the heater. Bulk fuel storage shall be outside the structure. f) All fuel storage shall be located a minimum

of 25 feet (762 cm) from heaters, torches, welding equipment, and similar sources of ignition (exception: the fuel reservoir integral with the heater unit). g) Whenever possible, fuel storage shall be

confined to areas where floor penetrations do not permit fuel to drip onto or be ignited by a fire at lower elevation. h) Fuel storage shall be in accordance with the

authority having jurisdiction. 3. Use only the electrical voltage and frequency specified on model plate. 4. Heater must be grounded. Use only a properly grounded three-wire extension cord. Plug into grounded outlet only. 5. Use only in areas free of flammable vapors or high dust content. 6. Minimum clearance from any combustible materials: 8 feet (244 cm) from hot air outlet; 4 feet (122 cm) from top; and 4 feet (122 cm) from sides and inlet. 7. Locate heater on a stable and level surface while hot or operating or a fire may occur. 8. Use only in well-vented areas. Before using heater, provide at least a three-square-foot (2800 square cm) opening of fresh, outside air for each 100,000 Btu/Hr (30 kw) of rating. 9. Keep children and animals away from heater at all times. 10. Never start heater when combustion chamber is hot or if fuel has accumulated in combustion chamber. 11. When used with thermostat, heater may start at anytime. 12. When heater is moved or stored, it must be in a level position or fuel spillage may occur. 13. Use heater only in accordance with local ordinances and codes. 14. Never use gasoline, crankcase drainings, naphtha, paint thinners, alcohol or other highly flammable fuels. 15. Never use heater where gasoline, paint thinner or other highly flammable vapors are present.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Make certain you read and understand all warn- ings. Keep this manual for reference. It is your guide to safe and proper operation of this heater. 1. Use only kerosene, #1#2 diesel/fuel oil, JET A or JP-8 fuels to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol or other highly flammable fuels. 2. Fueling a) Personnel involved with fueling shall be

qualified and thoroughly familiar with the manufacturerʼs instructions and applicable regulations regarding the safe fueling of heating units. b) Only the type of fuel specified on the

heaterʼs data plate shall be used. c) All flame, including the pilot light, if any,

shall be extinguished and the heater allowed to cool, prior to fueling.

Page 3 of the Desa UKC70ET user manual — PRODUCT IDENTIFICATION
Page 3 · cliquer pour agrandir
Page 3

SAFETY INFORMATION

Continued

Desa UKC70ET — Continued diagram (page 3)
Fig. 1 · Continued

16. Never use heater in living or sleeping areas. 17. Never leave a heater plugged in without adult supervision if children or animals are likely to be present. 18. Never move, handle, refuel or service a hot, operating or plugged-in heater. 19. Never attach duct work to front or rear of heater. 20. Never attach heater to external fuel tank. 21. Heaters used in the vicinity of tarpaulins, canvas or similar enclosure materials shall be located a safe distance from such materials. The recommended minimum safe distance is 10 feet (304.8 cm). It is further recommended that these enclosure materials be of a fire retardant nature. These enclosure materials shall be securely fastened to prevent them from igniting or from upsetting the heater due to wind action. 22. Unplug heater when not in use. 23. Never block air inlet (rear) or air outlet (front) of heater.

Figure 2 - 55/70 Model

Desa UKC70ET — Continued diagram (page 3)
Fig. 2 · Continued

UNPACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

Ignition Control Assembly (On Inside of Side Cover)

ON/OFF Switch with Light

PRODUCT IDENTIFICATION

Figure 3 - 115 Model

Hot Air Outlet Fan Guard

Fuel Cap/ Gauge Hot Air Outlet

Desa UKC70ET — PRODUCT IDENTIFICATION diagram (page 3)
Fig. 3

Figure 4 - 165 Model

Figure 1 - 40 Model

Show 4 more labels / short text on this page
Hot Air Outlet · Hot Air Outlet · Thermostat Knob · Fuel Tank
Page 4 of the Desa UKC70ET user manual — THEORY OF OPERATION
Page 4 · cliquer pour agrandir
Page 4

FUELS

VENTILATION

  • Use only kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels. Heavier fuels such as No. 2 fuel oil or No. 2 diesel fuel may also be used but will result in:
  • noticeable odor
  • additional fuel filter maintenance
  • the need for nontoxic, anti-icer additives in very cold weather Do not use fuels heavier than No. 2 grade or heavy oils such as oil drained from crankcases. These heavy oils will not ignite properly and will contaminate the heater. IMPORTANT: Use a KEROSENE ONLY (blue) or DIESEL ONLY (yellow) storage container. Be sure storage container is clean. Foreign matter such as rust, dirt or water will cause the ignition control assembly to shut down heater. Foreign matter may also require heaterʼs fuel system to be frequently cleaned.
  • Example: A 200,000 Btu/Hr (58.6 kw) heater requires one of the following:
  • a two-car garage door [16 feet (4.88 meter) opening] raised 5 inches (12.7 cm)
  • a single-car garage door [9 feet (2.74 meter) opening] raised 8 inches (20.3 cm)
  • two, 30 inch (76.2 cm) windows raised 15 inches (38.1 cm)

THEORY OF OPERATION

The Fuel System: The air pump forces air through the air line. The air is then pushed through the nozzle. This air causes fuel to be lifted from the tank. A fine mist of fuel is sprayed into the combus- tion chamber.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System: The ignition control assembly provides power to the ignitor. This ignites the fuel/air mixture in the combustion chamber.

The Flame-Out Control System: This system causes the heater to shut down if the flame goes out.

Fan Combustion Chamber Ignitor

Air Pump Air Intake Filter

Clean Heated Air Out

Air Line To Burner

Air For Fuel System

Air For Combustion And Heating

Figure 5 - Cross Section Operational View

Show 7 more labels / short text on this page
Motor · Cool Air In · Air Output Filter · Nozzle Fuel Tank · Fuel Filter · Ignition Control Assembly · Fuel
Page 5 of the Desa UKC70ET user manual — ASSEMBLY
Page 5 · cliquer pour agrandir
Page 5

ASSEMBLY

(FOR 115 AND 165 MODELS ONLY) These models are furnished with wheels and a handle. Some models are furnished with a second handle also. Wheels, handle(s), and the mounting hardware are found in the shipping carton.

(FOR 40, 55 AND 70 MODELS ONLY) These models are furnished with a nose cone guard. Nose cone guard and mounting screws are found in the shipping carton.

  • Tools Needed
  • Medium Phillips Screwdriver
  • 3/8" Open or Adjustable Wrench
  • Hammer 1. Slide axle through wheel support frame. Install wheel spacers if provided. Install wheels on axle. IMPORTANT: When installing wheels, point extended hub of wheels toward wheel support frame (see Figure 7). 2. Place cap nuts on axle ends. Gently tap with hammer to secure. 3. Place heater on wheel support frame. Line up holes on fuel tank flange with holes on wheel support frame. Be sure wheels are mounted under the air inlet of heater. 4. Place handle(s) on top of fuel tank flange. Insert screws through handle(s), fuel tank flange, and wheel support frame. Attach nut finger tight after each screw is inserted. If only one handle is provided, be sure to mount handle over outlet end of heater. 5. After all screws are inserted, tighten nuts firmly.

Tools Needed • 5/16" nut driver or wrench 1. Place nose cone guard on top of upper shell flange. Make sure nose cone guard is on hot air outlet end of heater. 2. Insert screws through nose cone guard and upper shell flange. 3. Tighten screws firmly.

Desa UKC70ET — ASSEMBLY diagram (page 5)
Fig. 4

Cord Cleat with Bolts and Nuts (If provided) Handle

Desa UKC70ET — ASSEMBLY diagram (page 5)
Fig. 5

Figure 6 - Nose Cone Guard Assembly,

Figure 7 - Wheel and Handle Assembly,

Show 5 more labels / short text on this page
40/55/70 Models Only · Hot Air Outlet · Fuel Tank Flange · Wheel · 115/165 Models Only
Page 6 of the Desa UKC70ET user manual — TO RESTART HEATER
Page 6 · cliquer pour agrandir
Page 6

OPERATION

TO STOP HEATER

Desa UKC70ET — TO STOP HEATER diagram (page 6)
Fig. 6

Without ON/OFF Switch Unplug extension cord from outlet.

With ON/OFF Switch Push ON/OFF switch to OFF (O) position. Unplug heater when not in use.

TO RESTART HEATER

Without ON/OFF Switch 1. Unplug extension cord from outlet and wait 10 seconds. (Wait two minutes if heater has been running.) 2. Repeat steps under To Start Heater.

TO START HEATER 1. Follow all ventilation and safety information. 2. Locate heater to provide maximum circulation of the heated air. Follow all location require- ments noted in Safety Information, page 2. 3. Fill fuel tank with kerosene, #1#2 diesel/fuel oil, JET A or JP-8 fuel. 4. Attach fuel cap. 5. For thermostat models, turn thermostat knob clockwise to the high position. 6. Plug heaterʼs power cord into approved, grounded, three-wire extension cord. Extension cord must be at least six feet (1.8 meters) long. Extension Cord Size Requirement 6 to 10 feet (1.8 to 3 meters) long, use 18 AWG (0.75 mm2) rated cord 11 to 100 feet (3.3 to 30.5 meters) long, use 16 AWG (1.0 mm2) rated cord 101 to 200 feet (30.8 to 61 meters) long, use 14 AWG (1.5 mm2) rated cord 7. Plug extension cord into standard 120 volt/60 hertz, 3-prong grounded outlet. Note: For heater without ON/OFF switch, ignitor will preheat for five seconds, then heater will start. Note: For heater with ON/OFF switch, push switch to ON(|) position and heater should start in 5 seconds. If heater does not start, see Troubleshooting, page 9. 8. For thermostat models, adjust thermostat knob to the desired setting. Note: A cold heater may affect the thermostat setting. This thermostat is a general-heating control. It is not intended for precise temperature control. Adjust thermostat until heater cycles at the desired setting.

With ON/OFF Switch 1. Push ON/OFF switch to OFF (O) position and wait 10 seconds (2 minutes if heater has been running). 2. Repeat steps under To Start Heater.

Desa UKC70ET — TO RESTART HEATER diagram (page 6)
Fig. 7

ON/OFF Switch with Light

Figure 8 - ON/OFF Switch, 55/70 Models

ON/OFF Switch with Light

Figure 9 - ON/OFF Switch, 115/165

Models

Page 7 of the Desa UKC70ET user manual — OPERATION WITH PORTABLE GENERATOR
Page 7 · cliquer pour agrandir
Page 7

OPERATION WITH PORTABLE GENERATOR

STORING, TRANSPORTING OR

Desa UKC70ET — OPERATION WITH PORTABLE GENERATOR diagram (page 7)
Fig. 8

SHIPPING Note: If shipping, transport companies require fuel tanks to be empty. 1. Drain fuel tank. Note: Some models have drain plug on underside of fuel tank. If so, re- move drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed. 2. Replace drain plug if provided. 3. If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters during future use. 4. Replace fuel cap or drain plug. Properly dis- pose of old and dirty fuel. Check with local automotive service stations that recycle oil. 5. If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes. IMPORTANT: Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater.

The operating voltage range of the heater is 108 to 132 Volts (120 Volts +/- 10%). Prior to plugging heater into generator the output voltage should be verified (if generator is equipped with the au- tomatic idle feature, the output voltage should be measured with the generator running at full speed). If the voltage does not measure in this range the heater should not be plugged into the generator. Refer to Operation, page 6, for starting, stopping, and resetting heater procedures.

Desa UKC70ET — OPERATION WITH PORTABLE GENERATOR diagram (page 7)
Fig. 9

Copper or Brass Grounding Point

Figure 10 - Typical Generator Grounding

Method (Generator construction may

vary from that shown)

Page 8 of the Desa UKC70ET user manual — WARNING: High voltage!
Page 8 · cliquer pour agrandir
Page 8

PREVENTATIVE MAINTENANCE SCHEDULE

Item

How To

How Often

Flush every 150-200 hours of operation or as needed

See Storing, Transporting, or Shipping, page 7

Air output and lint filters

Replace every 500 hours of operation or once a year

See Air Output, Air Intake, and Lint Filters, page 10

Wash and dry with soap and water every 500 hours of operation or as needed

See Air Output, Air Intake, and Lint Filters, page 10

Clean twice a heating season or as needed

See Fuel Filter, page 11

Clean every season or as needed

See Fan, page 10

TROUBLESHOOTING

FAULT CONDITION

POSSIBLE CAUSE

REMEDY

Motor does not start five seconds after heater is plugged in

1. No power to heater
1. Check circuit breaker in electrical panel 2. Verify the ON/OFF switch is in ON (|) position and light is on 3. Turn thermostat knob to a higher setting
2. ON/OFF switch not in the ON(|) position 3. Thermostat setting is too low

WARNING: High voltage!

4. Bad electrical connection between motor and ignition control assembly or ignition control assembly and power cord 5. Binding pump rotor
4. Check all electrical connections. See Wiring Diagrams, page 25
5. If fan does not turn freely, see Pump Rotor, page 14 6 Replace ignition control assembly 7. Replace motor 8. See Ignition Control Assembl y, page 15
6. Defective ignition control assembly 7. Defective motor 8. Blown fuse or ignitor control assembly
Show 8 more labels / short text on this page
Fuel tank · Air intake filter · Fuel filter · Ignitor · No maintenance required · Fan blades · Motor · Not required/permanently lubricated
Page 9 of the Desa UKC70ET user manual — WARNING: High voltage!
Page 9 · cliquer pour agrandir
Page 9

TROUBLESHOOTING

Continued

FAULT CONDITION

POSSIBLE CAUSE

REMEDY

Motor starts and runs but heater does not ignite

1. No fuel in tank 2. Pump pressure incorrect
1. Fill tank with kerosene 2. See Pump Pressure Adjustment, page 11 3. See Fuel Filter, page 11 4. See Nozzle Assembly, page 13 5. Drain and flush fuel tank with clean kerosene. See Storing, Transporting or Shipping, page 7
3. Dirty fuel filter 4. Obstruction in nozzle 5. Water in fuel tank

WARNING: High voltage!

6. Bad electrical connection between ignitor and ignition control assembly 7. Defective ignitor 8. Defective ignition control assembly
6. Check electrical connections. See Wiring Diagrams, page 25
7. Replace ignitor, see page 12 8. Replace ignition control assembly

Heater ignites but ignition con- trol assembly shuts heater off after a short period of time

1. Pump pressure incorrect
1. See Pump Pressure Adjustment, page 11 2. See Air Output, Air Intake, and Lint Filters, page 10 3. See Fuel Filter, page 11 4. See Nozzle Assembly, page 13 5. Make sure photocell boot is properly seated in bracket 6. Clean photocell lens
2. Dirty air intake, air output, and/or lint filter 3. Dirty fuel filter 4. Obstruction in nozzle 5. Photocell assembly not properly installed (not seeing the flame) 6. Dirty photocell lens

WARNING: High voltage!

7. Bad electrical connection between photocell and ignition control assembly 8. Defective photocell 9. Defective ignition control assembly
7. Check electrical connections. See Wiring Diagrams, page 25
8. Replace photocell 9. Replace ignition control assembly
Page 10 of the Desa UKC70ET user manual — SERVICE PROCEDURES
Page 10 · cliquer pour agrandir
Page 10

SERVICE PROCEDURES

4. Clean fan using a soft cloth moistened with kerosene or solvent. 5. Dry fan thoroughly. 6. Replace fan on motor shaft. Place fan hub flush with end of motor shaft (see Figure 14). 7. Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds/4.5-5.6 n-m). 8. Replace fan guard and upper shell.
Desa UKC70ET — SERVICE PROCEDURES diagram (page 10)
Fig. 10

UPPER SHELL REMOVAL 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together. See Figure 11 or 12. 2. Lift upper shell off. 3. Remove fan guard.

Desa UKC70ET — SERVICE PROCEDURES diagram (page 10)
Fig. 11
Desa UKC70ET — SERVICE PROCEDURES diagram (page 10)
Fig. 12

Figure 13 - Fan, Motor Shaft, and

Desa UKC70ET — SERVICE PROCEDURES diagram (page 10)
Fig. 13
Desa UKC70ET — SERVICE PROCEDURES diagram (page 10)
Fig. 14

Figure 14 - Fan Cross Section

AIR OUTPUT, AIR INTAKE AND LINT FILTERS 1. Remove upper shell (see Figure 11 or 12). 2. Remove filter end cover screws using 5/16" nut- driver (see Figure 15 or Figure 16, page 11). 3. Remove filter end cover. 4. Replace air output and lint filters. 5. Wash or replace air intake filter (see Preventa- tive Maintenance Schedule, page 8).

Desa UKC70ET — SERVICE PROCEDURES diagram (page 10)
Fig. 15

FAN IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch (see Figure 13). 1. Remove upper shell (see Figure 11 or 12). 2. Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft. 3. Slip fan off motor shaft.

Figure 15 - Air Output, Air Intake, and

Lint Filters, 40/55/70 Models Only

Show 8 more labels / short text on this page
Fan Guard · Setscrew Location · Motor · Flush · 40/55/70 Models Only · Upper Shell · Fan Guard · Filter End Cover
Page 11 of the Desa UKC70ET user manual — Continued
Page 11 · cliquer pour agrandir
Page 11

SERVICE PROCEDURES

FUEL FILTER 1. Remove side cover screws using 5/16" nut- driver. 2. Remove side cover. 3. Pull upper fuel line off fuel filter neck (see Figure 19 or 20). 4. Carefully pry bushing, fuel filter, and lower fuel line (115/165 Models only) out of fuel tank (see Figure 20). 5. Wash fuel filter with clean fuel and replace in tank. 6. Attach upper fuel line to fuel filter neck. 7. Replace side cover.

Continued

6. Replace filter end cover. 7. Replace fan guard and upper shell. IMPORTANT: Do not oil filters.

Fuel Filter and Bushing

Figure 16 - Air Output, Air Intake, and

Lint Filters, 115/165 Models Only

PUMP PRESSURE ADJUSTMENT 1. Remove pressure gauge plug from filter end cover (see Figure 17). 2. Install accessory pressure gauge (part number HA1180). 3. Start heater (see Operation, page 6). Allow motor to reach full speed. 4. Adjust pressure. Turn relief valve to right to increase pressure. Turn relief valve to left to decrease pressure. See specifications correct pressure for each model (see Figure 18). 5. Remove pressure gauge. Replace pressure gauge plug in filter end cover.

Figure 19 - Fuel Filter Removal,

Desa UKC70ET — Continued diagram (page 11)
Fig. 16 · Continued

Pump Model Pressure 40 3.0 PSI 55 3.4 PSI 70 4.7 PSI 115 5.1 PSI 165 5.6 PSI

Figure 18 - Adjusting Pump Pressure

Show 8 more labels / short text on this page
Air Intake Filter · Filter End Cover · Lint Filter · Air Output Filter · Upper Fuel Line · Side Cover · 40/55/70 Models · (70 Model Shown)
Page 12 of the Desa UKC70ET user manual — SERVICE PROCEDURES
Page 12 · cliquer pour agrandir
Page 12

SERVICE PROCEDURES

Continued IGNITOR 1. Remove upper shell and fan guard (See Upper Shell Removal, page 10). 2. Remove fan (see page 10). 3. Remove 4 side cover screws with a 5/16" nut driver. Remove side cover (see Figures 19 or 20, page 11). 4. Disconnect ignitor wires from ignition control assembly (see Figure 21). Pull the ignitor wires up through the hole in the lower shell. 5. Disconnect fuel line hose and air line hose. Remove photocell from photocell bracket (see Figure 21). 6. Remove combustion chamber. Stand com- bustion chamber on end with nozzle adapter bracket on top (see Figure 22). 7. Remove ignitor screw with a 1/4" nut driver. Carefully remove ignitor from nozzle adapter bracket.

Figure 21 - Disconnecting Ignitor Wires

from Ignition Control Assembly

Desa UKC70ET — SERVICE PROCEDURES diagram (page 12)
Fig. 17

8. Carefully remove replacement ignitor from packing. 9. Carefully guide ignitor into opening in nozzle adapter bracket. Do not strike ignitor element. Attach ignitor to nozzle adapter bracket with screw using a 1/4" nut driver (see Figure 23). Torque .90 to 1.69 N-m (8 to 15 in-lbs) Do not over torque. 10. Replace combustion chamber. 11. Route the ignitor wires back down through the hole in the lower shell. Connect wires to the ignition control assembly (see Figure 22). 12. Replace side cover (see Figures 19 or 20, page 11). 13. Connect and route fuel line hose and air line hose to nozzle adapter assembly. See Fuel and Air Line Replacement and Proper Routing, page 14. 14. Replace photocell in photocell bracket. Route wires as shown in either (see Figure 23 or Figure 24, page 13). 15. Replace fan (see page 10). 16. Replace fan guard and upper shell (see page 10).

Combustion Chamber Nozzle Adapter Bracket Opening Figure 22 - Ignitor Replacement

Figure 23 - Removing Air and Fuel Line

Hoses (40/55/70 Models Only)

Show 14 more labels / short text on this page
Nozzle Adapter Bracket · Combustion Chamber · Air Line Hose · Ignitor · Fuel Line Hose · Ignitor Wire · Photocell Bracket · Ignition Control Assembly · Photocell Assembly · Side Cover · Nozzle Adapter Bracket · Photocell Bracket · Nozzle/ Adapter Assembly · Photocell Bracket
Page 13 of the Desa UKC70ET user manual — Service Procedures
Page 13 · cliquer pour agrandir
Page 13
Desa UKC70ET — Service Procedures diagram (page 13)
Fig. 18 · Service Procedures
11. Attach fuel and airline hoses to nozzle assembly. See Fuel and Air Line Replacement and Proper Routing, page 14. 12. Replace fan (see Fan , page 10). 13. Replace fan guard and upper shell (see Upper Shell Removal , page 10).

Figure 25 - Removing Nozzle/Adapter

NOZZLE ASSEMBLY 1. Remove upper shell (see Upper Shell Re- moval, page 10). 2. Remove fan (see Fan, page 10). 3. Remove fuel and air line hoses from nozzle as- sembly (see Figure 23, page 12 or Figure 24). 4. Turn nozzle assembly 1/4 turn to left and pull toward motor to remove (see Figure 25). 5. Place plastic hex-body into vise and lightly tighten. 6. Carefully remove nozzle from the nozzle adapter using 5/8" socket wrench (see Figure 26). 7. Blow compressed air through face of nozzle. This will free any dirt in nozzle area. 8. Inspect nozzle sleeve for damage. 9. Replace nozzle into nozzle adapter until nozzle seats. Tighten 1/3 turn more using 5/8" socket wrench 4.5 to 5.1 N-m (40 to 45 in-lbs). See Figure 26. 10. Attach nozzle assembly to burner strap (see Figure 25).

Desa UKC70ET — Service Procedures diagram (page 13)
Fig. 19 · Service Procedures

Figure 26 - Nozzle and Nozzle Adapter

Assembly · Nozzle Face · Nozzle

Page 14 of the Desa UKC70ET user manual — Continued
Page 14 · cliquer pour agrandir
Page 14

SERVICE PROCEDURES

PUMP ROTOR (Procedure if Rotor is Binding) 1. Remove upper shell (see Upper Shell Re- moval, page 10). 2. Remove filter end cover screws using 5/16" nut driver (see Figure 28 or 29). 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut-driver. 5. Remove pump plate. 6. Remove rotor, insert, and blades (see Figure 28 or 29). 7. Check for debris in pump. If debris is found, blow out with compressed air. 8. Install insert and rotor. 9. Check gap on rotor. Adjust to .076/.101 mm (.003"/.004") if needed (see Figure 30, page 15). Note: Rotate rotor one full turn to ensure the gap is .076/.101 mm (.003"/.004") at tightest position. Adjust if needed. 10. Install blades, pump plate, air filters, and filter end cover. 11. Replace fan guard and upper shell (see Upper Shell Removal, page 10). 12. Adjust pump pressure (see Pump Pressure Adjustment, page 11).

Continued

FUEL AND AIR LINE REPLACEMENT AND PROPER ROUTING 1. Remove upper shell (see Upper Shell Re- moval, page 10). 2. Remove side cover screws using 5/16" nut driver (see Figure 19 or 20, page 11). 3. Remove side cover. 4. Inspect fuel and air line hoses for cracks and/or holes. If fuel line hose is damaged, disconnect from nozzle adapter (see Figure 23 or 24) and from fuel filter (see Fuel Filter, page 11). If air line hose is damaged, disconnect from nozzle adapter (see Figure 23, page 12 or Figure 24, page 13) and from barb fitting on pump end cover (see Figure 27). 5. Install new air and/or fuel line. Attach one end of air line hose to barb fitting on pump end cover (see Figure 27) and the other end to nozzle adapter (see Figure 23, page 12 or Figure 24, page 13). Attach one end of fuel line hose to fuel filter (see Fuel Filter, page 11) and the other end to nozzle adapter (see Figure 23, page 12 or Figure 24, page 13). Note: Route hoses as shown in Figure 23, page 12 or Figure 24, page 13, according to model. Hoses are not to touch photocell bracket. 6. Replace side cover. 7. Replace upper shell and fan guard (see Upper Shell Removal, page 10).

Desa UKC70ET — Continued diagram (page 14)
Fig. 20 · Continued

Figure 29 - Rotor Location, 115/165

Models

Page 15 of the Desa UKC70ET user manual — IGNITION CONTROL ASSEMBLY
Page 15 · cliquer pour agrandir
Page 15

SERVICE PROCEDURES

IGNITION CONTROL ASSEMBLY

Continued

WARNING: High voltage!

1. Unplug heater. 2. Remove side cover screws (4) using 5/16" nutdriver to expose ignition control assembly. 3. Remove fuse cover (see Figure 32). 4. Remove fuse from fuse clips (see Figure 32). 5. Replace fuse with fuse of the same type and rating (GMA-10). Do not substitute a fuse with a higher current rating. 6. Replace fuse cover (see Figure 32). 7. Replace side cover (see Figures 19 or 20, page 11).
Desa UKC70ET — IGNITION CONTROL ASSEMBLY diagram (page 15)
Fig. 21

.003"/.004" (.076-.101 mm) Gap Measured With Feeler Gauge

Desa UKC70ET — IGNITION CONTROL ASSEMBLY diagram (page 15)
Fig. 22

Gap Adjusting Screw Figure 30 - Gap Adjusting Screw

Figure 31 - Sanding Rotor

SPECIFICATIONS Model Size 40 55 70 115 165 Output Rating (Btu/Hr) 40,000 55,000 70,000 115,000 165,000 Fuel Use only kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels* Fuel Tank Capacity (U.S. Gal./Liters) 3/11.3 5/18.9 5/18.9 9/34 13.5/51 Fuel Consumption (Gal. Per Hr/Liters Per Hr) .3/1.14 .44/1.67 .52/1.97 .85/3.00 1.2/4.54 Pump Pressure (psi) 3.0 3.4 4.7 5.1 5.6 Electric Requirements 120 V/60 HZ (Same All Models) Amperage (Normal Run) 2.0 2.0 2.8 3.6 3.6 Motor RPM 1725 1725 3440 3440 3440 Hot Air Output (CFM) 170 180 360 490 575 Shipping Weight 32/14.5 35/15.9 35/15.9 54/24.5 65/29.5 (Approximate lbs./kg) Heater Weight without Fuel 28/12.2 30/14 30/14 46/21 55/25 (Approximate lbs./kg) * Use of #2 diesel & fuel oil will result in noticeable odor and could require additional fuel filter main- tenance. Use in extreme cold temperatures may require nontoxic anti-icer additives.

Gap Adjusting Screw · Locations · Sandpaper

Page 16 of the Desa UKC70ET user manual — MODELS BC40 AND RC40
Page 16 · cliquer pour agrandir
Page 16

ILLUSTRATED PARTS BREAKDOWN

MODELS BC40 AND RC40

Desa UKC70ET — MODELS BC40 AND RC40 diagram (page 16)
Fig. 23
Page 17 of the Desa UKC70ET user manual — PARTS AVAILABLE - NOT SHOWN
Page 17 · cliquer pour agrandir
Page 17

PARTS LIST

MODELS BC40 AND RC40 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.

KEY PART NO. NUMBER DESCRIPTION QTY.

1 M51104-01 Handle 1 2 098511-67 Upper Shell (Service Part Will Be Black) 1 3 M11084-29 Screw, #10-16 x 3/4" 2 4 108631-01 Screw, #10-16 x 1" 2 5 098512-58 Combustion Chamber 1 6 M10908-2 Screw, #6-32 x 3/8" 2 7 103154-03 Photocell Bracket 1 8 M16656-24 Photocell Assembly 1 9 (see page 22) Burner Head Assembly 1 10 M11084-26 Screw, #10-16 x 3/8" 2 11 103684-01 Fan 1 12 (see page 22) Motor 1 13 M51105-01 Fan Guard 1 14 098219-38 Power Cord 1 15 M11143-1 Strain Relief Bushing 1 16 NTC-4C Hex Lock Nut, 1/4-20 2 17 M11084-26 Screw, #10-16 x 3/8" 4 18 M50631 Rubber Bumper 2 19 097461-09 Side Cover 1 20 101205-01 Motor Bracket 1 21 M30865-02 Bushing 2 22 M11271-8 Clip Nut 6 23 M50104-02 Bushing 1 24 M11084-26 Screw, #10-16 x 3/8" 6 25 M10908-14 Screw, #8-32 x 3/8" 1 26 098511-234 Lower Shell (Service Part will be Black) 1 27 M50814-06 Rubber Airline 1 28 079973-01 Fuel Line 1 29 M50876-04 Fuel Filter with bushing 1 30 M10990-3 Rubber Bushing 1 31 079532-01 Guard, Nose Cone 1 32 102349-01 PCB Support 5 33 104068-02 Ignition Control Assembly 1 34 097702-01 Fuel Cap (Includes Gasket) 1 35 108088-01 Fuel Tank 1 36 M51108-01 Shell Heat-Shield 1 37 M15823-27 Screw, #10-16 x 1/2" 4

PARTS AVAILABLE - NOT SHOWN

103814-01 Wire Tie 1 105550-01 Warning/Maintenance Decal 1 105550-02 Warning/Maintenance Decal 1

Page 18 of the Desa UKC70ET user manual — MODELS BC55CT, RC55CT, UKC55CT, BC70ET, RC70ET AND UKC70ET
Page 18 · cliquer pour agrandir
Page 18

ILLUSTRATED PARTS BREAKDOWN

MODELS BC55CT, RC55CT, UKC55CT, BC70ET, RC70ET AND UKC70ET

Desa UKC70ET — MODELS BC55CT, RC55CT, UKC55CT, BC70ET, RC70ET AND UKC70ET diagram (page 18)
Fig. 24
Page 19 of the Desa UKC70ET user manual — PARTS LIST
Page 19 · cliquer pour agrandir
Page 19

PARTS LIST

MODELS BC55CT, RC55CT, UKC55CT, BC70ET, RC70ET AND UKC70ET This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.

KEY PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-67 Upper Shell (Service Part Will Be Black) 1 3 M11084-29 Screw, #10-16 x 3/4" 2 4 108631-01 Screw, #10-16 x 1" 2 5 098512-50 Combustion Chamber (55) 1 098512-51 Combustion Chamber (70) 1 6 M10908-2 Screw, #6-32 x 3/8" 2 7 103154-03 Photocell Bracket 1 8 M16656-24 Photocell Assembly 1 9 (see page 22) Burner Head Assembly 1 10 M11084-26 Screw, #10-16 x 3/8" 2 11 103684-01 Fan (55) 1 M29678 Fan (70) 1 12 (see page 22) Motor and Pump Assembly 1 13 M51105-01 Fan Guard 1 14 113065-01 Power Cord 1 15 M11143-1 Strain Relief Bushing 1 16 NTC-4C Hex Lock Nut, 1/4-20 2 17 M11084-26 Screw, #10-16 x 3/8" 8 18 M50631 Rubber Bumper 2 19 097461-16 Side Cover 2 20 101205-01 Motor Bracket 1 21 M50104-06 Bushing 1 22 M11271-8 Clip Nut 6 23 M50104-02 Bushing 1 24 M11084-26 Screw, #10-16 x 3/8" 6 25 M10908-14 Screw, #8-32 x 3/8" 1 26 098511-234 Lower Shell (Service Part Will Be Black) 1 27 M50814-06 Rubber Airline 1 28 079973-01 Fuel Line 1 29 M50876-05 Fuel Filter with bushing 1 30 M10990-3 Rubber Bushing 1 31 102349-01 PCB Support 5 32 104068-02 Ignition Control Assembly 1 33 113280-01 Fuel Cap w/ Gauge (includes Gasket) (Use with Fuel Tank 113279-01) 1 34 113279-01 Fuel Tank (Plastic Filler Neck) 1 35 M51108-01 Shell Heat-Shield 1 36 104458-01 Thermostat 1 37 M12461-18 Screw, #8-32 x 7/8" 1 38 104460-01 Thermostat Knob 1 39 WLE-2 Lock Washer, EXT #8 1 40 113461-01 ON/OFF Switch 1 41 M15823-27 Screw #10-16 x 1/2" 4 42 079532-01 Nose Cone Guard 1 PARTS AVAILABLE - NOT SHOWN 103814-01 Wire Tie (For Ignition Control Assembly) 1 M9900-170 Wire Assembly (Thermostat to Ignition Control Assembly) 1 079010-46 Wire Assembly (Connects Switch to Thermostat or Ignition Control) 1

Page 20 of the Desa UKC70ET user manual — MODELS BC115DT, RC115DT, UKC115DT, BC165DT, RC165DT AND UKC165DT
Page 20 · cliquer pour agrandir
Page 20

ILLUSTRATED PARTS BREAKDOWN

MODELS BC115DT, RC115DT, UKC115DT, BC165DT, RC165DT AND UKC165DT

Desa UKC70ET — MODELS BC115DT, RC115DT, UKC115DT, BC165DT, RC165DT AND UKC165DT diagram (page 20)
Fig. 25
Page 21 of the Desa UKC70ET user manual — PARTS LIST
Page 21 · cliquer pour agrandir
Page 21

PARTS LIST

MODELS BC115DT, RC115DT, UKC115DT, BC165DT, RC165DT AND UKC165DT This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.

KEY PART NO. NUMBER DESCRIPTION QTY. 1 098511-292 Upper Shell (Service Part Will Be Black) 1 2 M15823-27 Screw, #10-16 x 1/2" 8 3 098512-71 Combustion Chamber (115) 1 098512-75 Combustion Chamber (165) 1 4 103154-05 Photocell Bracket (115) 1 M16660-02 Photocell Bracket (165) 1 5 M10908-2 Screw, #6-32 x 3/8" 2 6 M16656-24 Photocell Assembly 1 7 (See page 22) Burner Head Assembly 1 8 M11084-26 Screw, #10-16 x 3/8" 2 9 097293-01 Fan (115) 1 102042-01 Fan (165) 1 10 (See page 23) Motor and Pump Assembly 1 11 M50631 Rubber Bumper 2 12 101206-01 Motor Mounting Bracket 1 13 M12461-18 Screw, #8-32 x 7/8" 1 14 104068-02 Ignition Control Assembly 1 15 NTC-4C Hex Lock Nut, 1/4-20 2 16 111037-01 Fan Guard 1 17 M27417 Drain Plug (Includes “o” Ring) 1 18 107878-02 Button Plug 1 19 M51345-06 Fuel Line 1 20 106896-01 Fuel Filter 1 21 M51151-01 Fuel Line Tube (115) 1 M51151-02 Fuel Line Tube (165) 1 22 M10990-3 Rubber Bushing 1 23 M50814-03 Airline 1 24 098511-293 Lower Shell (Service Part Will Be Black) 1 25 M50104-06 Bushing 1 26 M50104-01 Bushing 1 27 M11084-26 Screw, #10-16 x 3/8" 6 28 M11271-8 Clip Nut 8 29 M10908-14 Screw, #8-32 x 3/8" 1 30 113279-02 Fuel Tank 115 1 113279-03 Fuel Tank 165 1 31 113280-02 Fuel Cap w/ Gauge (includes Gasket) 115 1 113280-03 Fuel Cap w/ Gauge (includes Gasket) 165 1 32 102349-01 P.C. Board Support 5 33 M11143-1 Strain Relief Bushing 1 34 113065-01 Power Cord 1 35 M51077-18 Side Cover 2 36 M11084-26 Screw, #10-16 x 3/8" 8 37 104460-01 Thermostat Knob 1 38 104458-01 Thermostat 1 39 WLE-2 Lock Washer, EXT #8 1 40 113461-01 ON/OFF Switch with Light 1 103814-01 Wire Tie (Not Shown - Groups wires connected to Ignition Control Assembly) 1 M9900-77 Wire (Not Shown - Connects T-stat to Ignition Control Assembly) 1 079010-46 Wire (Not Shown - Connects ON/OFF Switch to Ignition Control Assembly or Thermostat if Equipped) 1

Page 22 of the Desa UKC70ET user manual — BURNER HEAD ASSEMBLY
Page 22 · cliquer pour agrandir
Page 22

ILLUSTRATED PARTS BREAKDOWN

BURNER HEAD ASSEMBLY

Desa UKC70ET — BURNER HEAD ASSEMBLY diagram (page 22)
Fig. 26

KEY PART NO. NUMBER DESCRIPTION QTY. 1 HA3006 Nozzle Assembly (40) 1 HA3024 Nozzle Assembly (55) 1 HA3026 Nozzle Assembly (70) 1 HA3027 Nozzle Assembly (115) 1 HA3028 Nozzle Assembly (165) 1 2 HA1000 Ignitor Kit 1 3 M10908-75 Screw, #6-32 x 7/8" 1 4 102336-01 Nozzle Adapter Bracket 1 5 104056-01 Nozzle Adapter (40) 1 104054-01 Nozzle Adapter (55/70/115/165) 1 6 103347-01 Washer 1

MOTOR AND PUMP ASSEMBLY MODELS BC40, RC40, BC55CT, RC55CT, UKC55CT, BC70ET, RC70ET AND UKC70ET

KEY PART NO. NUMBER DESCRIPTION QTY. 1 102001-01 Motor (40/55) 1 102001-20 Motor (70) 1 2 079975-02 Pump Body (40/70) 1 079975-03 Pump Body (55) 1 3 M22009*, ** Insert 1 4 M22456-1* Rotor (40 & 70) 1 M22456-2** Rotor (55) 1 5 M29608 Pump End Cover 1 6 M29632*** Lint Filter 1 7 M29633*** Intake Filter 1 8 M29609 Filter End Cover 1 9 M12461-31 Screw, #10-32 x 1" 3 10 M27694 ∞ Adjusting Screw 1 11 M10993-1 ∞ Pressure Relief Spring 1 12 M22997 ∞ Plug 1 13 M8940 ∞ Steel Ball, 1/4" Diameter 1 14 M29612-01*** Output Filter 1 15 M12461-31 Screw, #10-32 x 1" (40/70) 6 M12461-32 Screw, #10-32 x 1 1/8" (55) 6 16 103676-01 Nylon Elbow, 90° 1 17 M8643* Blade (40/70) 4 M8643-2** Blade (55) 4 18 FHPF3-5C Screw (40/70) 2 FHPF3-6C Screw (55) 2

* Included in Rotor Kit (Part No. HA3004) ** Included in Rotor Kit (Part No. HA3005) *** Included in Filter Kit (Part No. HA3014) ∞ Included in Pump

Adjustment Kit (Part No. HA3020)

Page 23 of the Desa UKC70ET user manual — MODELS BC115DT, RC115DT, UKC115DT, BC165DT, RC165DT AND UKC165DT
Page 23 · cliquer pour agrandir
Page 23

ILLUSTRATED PARTS BREAKDOWN

MODELS BC115DT, RC115DT, UKC115DT, BC165DT, RC165DT AND UKC165DT

Desa UKC70ET — MODELS BC115DT, RC115DT, UKC115DT, BC165DT, RC165DT AND UKC165DT diagram (page 23)
Fig. 27
Desa UKC70ET — MODELS BC115DT, RC115DT, UKC115DT, BC165DT, RC165DT AND UKC165DT diagram (page 23)
Fig. 28

1 102001-30 Motor 1 2 079975-02 Pump Body 1 3 FHPF3-5C Screw, #10-32 x 5/8" 2 4 M22009** Rotor Insert 1 5 M22456-1** Pump Rotor 1 6 M50545 Pump End Cover 1 7 M12179** Intake Filter 1 8 M16545 Filter End Cover 1 9 M8940** Steel Ball, 1/4" Diameter 1 10 M10993-1** Relief Spring 1 11 M27694** Adjusting Screw 1 12 M22997** Plug 1 13 M12461-31 Screw, #10-32 x 1" 10 14 M12244-1** Output Filter 1 15 M11637** Lint Filter 1 16 M50820-02 Barb Fitting 1 17 M8643** Blade 4

** Included in Rotor Kit (Part No. HA3004)

Page 24 of the Desa UKC70ET user manual — WHEELS AND HANDLE PARTS LIST
Page 24 · cliquer pour agrandir
Page 24

ILLUSTRATED PARTS BREAKDOWN

WHEELS AND HANDLE PARTS LIST

KEY PART NUMBER NO. 115 MODELS 165 MODELS DESCRIPTION QTY. 1 079998-02 099614-01 Handle, Front 1 2 M51334-02 099614-02 Handle, Rear (if provided) 1 3 M12345-33 M12345-33 Screw, #10-24 x 1 3/4" 8 4 M12342-3 M12831-5 Wheel Support Frame 1 5 NTC-3BZ NTC-3BZ Hex Nut, #10-24 8 6 107426-01 — Wheel Kit (115) (Contains 2 Black Wheels and Cap Nuts) 1 — 113326-01 Pneumatic Wheel Kit (165) (Contains 2 Black Wheels, Cap Nuts, & Spacers) 1 7 M28526 M28526 Cap Nut 2 8 M51015-01 M16801-5 Axle 1 9 — 113497-01 Wheel Spacer (165 only) 2 10 113193-01 113193-01 Cord Cleat Kit (if provided) (Contains 2 Cleats, 4 Nuts and 4 Bolts) 1

Page 25 of the Desa UKC70ET user manual — 120V (L1)
Page 25 · cliquer pour agrandir
Page 25

WIRING DIAGRAMS

120V (L1)

120V (L1)

Figure 33 - Wiring Diagrams

Show 52 more labels / short text on this page
Blue · Photocell · White Photocell · Ignition Control Assembly · Photocell · Blue · Ignitor · Green Green · Motor Return · White · Power Plug · 120V/60Hz · AC Neutral (L2) · Motor · Yellow · Black · Motor · Red · Black · Thermostat · Ignitor · Ignitor · Yellow · (40 Models) · Blue · Photocell · Ignition Control Assembly · Blue · Photocell · Photocell · White · Ignitor · Green · Motor Return · White · Power Plug · Black · 120V/60Hz · AC Neutral (L2) · Green · Motor · Yellow · Red Black · ON/OFF Switch · Motor · Black · Thermostat · with Light · Ignitor · Yellow · Ignitor · (55/70/115/155/165 Models)
Page 26 of the Desa UKC70ET user manual — Accessories
Page 26 · cliquer pour agrandir
Page 26

ACCESSORIES Heater accessories and parts are available at your local dealer. Should your dealer not stock or is un- able to order a particular accessory or part, please contact DESA Industries for more information. DESA Industries of Canada, Inc. 2220 Argentia Road, Unit #4 Mississauga, Ontario L5N 2K7 Parts Department 1-905-826-8010

THERMOSTAT KIT - HA1210 For 40 model. Keeps your building at the tempera- ture you select day and night. Helps economize on fuel.

AIR GAUGE KIT - HA1180 For all models. Special tool to check pump pressure.

IGNITION CONTROL ASSEMBLY/ PHOTOCELL TESTER - HA1170 Special tool used to test the ignition control as- sembly and photocell.

HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient. Fits 40/55/70 models.

Page 27 of the Desa UKC70ET user manual — _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
Page 27 · cliquer pour agrandir
Page 27

NOTES

Page 28 of the Desa UKC70ET user manual — REPAIR SERVICE
Page 28 · cliquer pour agrandir
Page 28

WARRANTY AND REPAIR SERVICE

KEEP THIS WARRANTY

Model No.

Serial No.

LIMITED WARRANTIES FOR NEW AND FACTORY

RECONDITIONED PRODUCTS

New Products: DESA Industries warrants this heater and any parts thereof, to be free of defects in materials and workmanship for one (1) year from the date of first purchase, when operated and maintained in accordance with the manufacturer's instructions. These warranties are extended only to the original retail purchaser, when proof of purchase is provided.

Factory Reconditioned Heaters: DESA Industries warrants this factory reconditioned heater and any parts thereof, to be free of defects in materials and workmanship for thirty (30) days from the date of first purchase, when oper- ated and maintained in accordance with the manufacturer's instructions. These warranties are extended only to the original retail purchaser, when proof of purchase is provided.

These warranties cover only the cost of parts and labor required to restore the product to proper operating condition. Transportation and incidental costs associated with warranty repairs are not reimbursable under this warranty.

Warranty service is available only through authorized dealers and service centers.

This warranty does not cover defects resulting from misuse, abuse, negligence, accidents, lack of proper maintenance, normal wear, alteration, modification, tampering, contaminated fuels, repair using improper parts or repair by anyone other than an authorized dealer or service center. Routine maintenance is the responsibility of the owner.

THIS EXPRESS WARRANTY IS GIVEN IN LIEU OF ANY OTHER WARRANTY EITHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

DESA Industries assumes no responsibility for indirect, incidental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations or exclusions may not apply to you. This Limited Warranty gives you specific legal rights and you may also have other rights which vary from province to province.

WARRANTY SERVICE

Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA Industries will repair or replace the heater without charge.

REPAIR SERVICE

Return the heater to your nearest authorized service center. Each Service Center is independently owned and operated. Repairs not covered by the warranty will be billed at standard prices. We reserve the right to amend these specifications at any time without notice.

Illustrated parts lists can be obtained free of charge. Send a self-addressed stamped envelope to the address listed below. List the heater model number and the date located in the lower right corner of this page. A service manual may be purchased from the address listed below. Send a cheque for $5.00 payable to DESA Industries.

When writing for information regarding your heater, be sure to include the model number and serial number as shown on the model plate.

2220 Argentia Road, Unit #4 Mississauga, Ontario L5N 2K7 (905) 826-8010 Fax (905) 826-8236

Date of Purchase · Printed in USA

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Desa UKC70ET

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Desa UKC70ET

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Desa UKC70ET manuel PDF

56 pages·2.8 MB·Radiateur électrique·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…