Manuel d'utilisation / d'entretien du produit SVYD18N du fabricant Desa
Aller à la page of 32
Save this manual for future reference. AMITY (VENT -FREE) NA TURAL GAS S T O V E HEA TER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 104024 CONTENTS SECTION PAGE SAFETY INFORMA TION WARNING ICON G 001 W ARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
3 104024 SAFETY INFORMA TION Continued WARNING ICON G 001 W ARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
4 104024 LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
5 104024 Continued AIR FOR COMBUSTION AND VENTILA TION WARNING ICON G 001 W ARNING This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventila- tion air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
6 104024 AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
7 104024 WARNING ICON G 001 W ARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus- tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.
8 104024 WARNING ICON G 001 W ARNING Never install the heater • in a bedroom or bathroom • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less th.
9 104024 INST ALLING Continued Figure 4 - Minimum Clearance to Walls and Ceiling STOVE CAVITY ASSEMBLY 1. Lift off corrugated box enclosing stove body crating. 2. Remove all screws fastening the wood frame enclosure. Spread wood frame open and lift away from plastic-bagged stove body.
10 104024 INST ALLING Continued Figure 6 - Laying Down Stove On Side Front of Stove Unit Pallet Wood Bolted to Stove Body Bottom Top of Stove Unit Front of Stove Unit Top of Stove Unit Drop Cloth/ Blanket 5. Remove all contents from inside stove cavity.
11 104024 8. Fasten each leg to stove with four (4) M8 x 1.25 - 20mm bolts. Use a flat washer and lock washer with each bolt. Tighten bolts into threaded holes on stove body (see Figure 8 and 9). Use an adjustable wrench or a 12mm socket. Figure 9 - Attaching Stove Legs Bottom Of Stove Unit Leg Bolt Washers INST ALLING Continued 9.
12 104024 INST ALLING Continued 10. Attach stove door by inserting step bolt through door hinge pivot hole and into threaded hole in stove body (see Figure 8 and 11). Use an adjustable wrench or a 12mm socket to fasten step bolt. Tighten step bolt until snug.
13 104024 INSTALLING GAS LOG HEATER INTO STOVE 1. Remove log and gas log heater from carton. Note: Do not pick up gas log heater by the burner itself. This could damage heater. Always handle the gas log heater by the heater base only. 2. Remove all protective packaging applied to log and gas log heater for shipment.
14 104024 INST ALLING Continued 8. Set one-piece log on heater base as shown in Figure 15. Make sure middle section at bottom of log is seated into "U" shaped cutout in center of heater base. Log will fit securely on base. IMPORTANT: Make sure log does not cover any burner ports and does not touch the stove cavity (see Figure 16).
15 104024 INST ALLING Continued * An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessory , page 30.
16 104024 INST ALLING Continued Tee Joint Pipe Nipple Cap 3" Minimum Sediment Trap Gas Regulator From Gas Meter (5" W.C.** to 10.5" W.C. Pressure) A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap* Approved Flexible Gas Hose (if allowed by local codes) Figure 18 - Gas Connection * Purchase the optional A.
17 104024 Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 19). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to manual shutoff valve (see Figure 20).
18 104024 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING ICON G 001 W ARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
19 104024 WARNING ICON G 001 W ARNING Do not operate heater between PILOT and HIGH positions. WARNING ICON G 001 CAUTION Do not try to adjust heating levels by using the manual shutoff valve.
20 104024 OPERA TING HEA TER Continued T O TURN OFF GAS T O APPLIANCE Shutting Off Heater 1. Press in and turn control knob clockwise Clockwise to the HIGH position. 2. Turn the control knob clockwise Clockwise to the PILOT position. 3. Press in control knob and turn clockwise Clockwise to the OFF Position.
21 104024 CLEANING AND MAINTENANCE WARNING ICON G 001 W ARNING Turn off heater and let cool before cleaning. WARNING ICON G 001 CAUTION You must keep control areas, burner, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use.
22 104024 TROUBLE- SHOOTING Continued REMEDY 1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5.
23 104024 OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial opera- tion Heater produces a whistling noise when burner is lit Moisture/condensation noticed on windows REMEDY 1.
24 104024 TROUBLE- SHOOTING Continued WARNING ICON G 001 W ARNING If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
25 104024 TECHNICAL SER VICE You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
26 104024 ILLUSTRA TED P ARTS BREAKDOWN SVYD18N 4 20 10 11 12 20 7 20 20 5 6 9 8 15 14 16 18 2 17 13 22 20 18 3 19-2 19-1 19 17 1 21.
27 104024 P ARTS LIST SVYD18N This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual.
28 104024 ILLUSTRA TED P ARTS BREAKDOWN SCIVFC, SCIVFB, SCIVFG, SCIVFR 1 2 5 11 7-4 6 5 5 7-1 7-2 5 4 7-3.
29 104024 P ARTS LIST SCIVFC, SCIVFB, SCIVFG, SCIVFR This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual.
30 104024 ACCESSOR Y Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the address listed on the back page of this manual.
31 104024 NOTES _________________________________________________________________ _________________________________________________________________ ____________________________________________________.
LIMITED WARRANTY VENT-FREE NATURAL GAS LOG HEATERS AND AMITY STOVE CHASSIS DESA International warrants this product to be free from defects in materials and components for three (3) years from the.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa SVYD18N c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa SVYD18N - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa SVYD18N, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa SVYD18N va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa SVYD18N, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa SVYD18N.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa SVYD18N. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa SVYD18N ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.