POR T ABLE FORCED AIR HEA TER OWNER’S MANUAL IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury.
2 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater .
3 104950 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - RJ45 Handle Fuel Cap Lower Shell Power Cord Fuel Tank Hot Air Outlet Air Filter End Cover Fan Guard Upper Shell Side Cover Ignition Control.
4 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 Figure 3 - Cross Section Operational View Fuel Filter Air Line To Burner Air Output Filter Air Pump Air Intake Filter Cool Air In Fan Combustion C.
5 104950 OWNER’S MANUAL Item Fuel tank Air output and lint filters Air intake filter Fuel filter RJ45: Ignitor RJ70: Spark Plug Fan blades Motor WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.
6 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 TROUBLESHOOTING RJ45 WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. REMEDY 1. Check circuit breaker in electrical panel 2. Check all electrical connections.
7 104950 OWNER’S MANUAL TROUBLESHOOTING Continued RJ70 WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.
8 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 PUMP PRESSURE ADJUSTMENT 1. Remove pressure gauge plug from filter end cover . 2. Install accessory pressure gauge (part number HA1 180). 3. Start heater (see Opera tion , page 5). Al- low motor to reach full speed.
9 104950 OWNER’S MANUAL Fuel Filter Side Cover Upper Fuel Line Figure 9 - Fuel Filter Removal FUEL FILTER 1. Remove side cover screws using 5/16" nut-driver (see Figure 9). 2. Remove side cover . 3. Pull upper fuel line off fuel filter neck. 4.
10 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 NOZZLE (RJ45) 1. Remove upper shell (see Upper Shell Removal , page 8). 2. Remove fan (see Fa n , page 8). 3. Remove fuel and air line hoses from nozzle adapter . 4. T urn nozzle adapter 1/4 turn to left and pull toward motor to remove.
11 104950 OWNER’S MANUAL Sandpaper Figure 22 - Sanding Rotor Figure 21 - Gap Adjusting Screw Locations Figure 20 - Rotor Location O TOR PFA/P 056 Insert Rotor Air Output Filter Blade Pump Plate Air Intake Filter Filter End Cover Fan Guard 0.
12 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 Figure 23- Wiring Diagram For RJ70 WIRING DIAGRAMS Figure 22- Wiring Diagram For RJ45 White Photo- cell Black Blue Flame- Out Control B Reset But.
13 104950 OWNER’S MANUAL ACCESSORIES Purchase accessories and parts from your nearest dealer. AIR GAUGE KIT - HA1180 Special tool to check pump pressure. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient.
14 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 9-1 9-2 9-3 9-4 9-5 17 18 19 20 21 22 23 24 25 26 27 28 29 30 34 35 36 32 38 33 31 42 41 40 39 37 ILLUSTRA.
15 104950 OWNER’S MANUAL P ARTS LIST RJ45 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.
16 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 ILLUSTRA TED P AR TS BREAKDOWN RJ70 40 41 43 5 47 46 2 4 3 6 7 8 10 11 12 12 14 18 21 22 24 27 28 29 30 31 32 34 38 37 19 13 9 33 35 36 42 39 23 .
17 104950 OWNER’S MANUAL P ARTS LIST RJ70 ∆ Not available as an assembly ** Included in Rotor Kit (Part No. HA3004) ⊕ Included in Filter Kit (Part No. HA3014) ∞ Included in Pump Adjustment Kit (Part No. HA3020) KEY PART PART NO. NUMBER DESCRIPTION QTY.
W ARRANTY AND REP AIR SER VICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workman- ship.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa RJ45 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa RJ45 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa RJ45, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa RJ45 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa RJ45, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa RJ45.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa RJ45. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa RJ45 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.