UNVENTED (VENT -FREE) GAS FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL Save this manual for future reference. Save this manual for future reference.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 2 SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 3 3 SAFETY INFORMA TION Continued PRODUCT IDENTIFICA TION Figure 2 - Fireplace (VYGF33PRA Shown) 1. This appliance is only for use with the type of gas indicated on the rating plate.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 4 LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 5 5 PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation .
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 6 The space in the example on page 5 is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 7 7 INST ALLA TION INSTALLATION Check Gas Type Electrical Hookup Installing Hood NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 8 * INST ALLA TION Continued Figure 7 - Attaching Brass Trim to Fireplace Figure 6 - Assembling Bra.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 9 9 INST ALLA TION Continued CONVENTIONAL FIREPLACE INSTALLATION Conventional installation of this fireplace involves installing fire- place along with the corner, face, or cabinet mantel with hearth base accessories against a wall in your home.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 10 INST ALLA TION Continued INSTALLATION Built-In Fireplace Installation Actual Framing Height 32 3.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 11 11 1. Frame in rough opening. Use dimensions shown in Figure 16 for the rough opening. 2. If using blo wer, install wiring and properly ground the three- prong, 120 volt electrical outlet in fireplace.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 12 INST ALLA TION Continued Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 13 13 Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 22).
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 14 INST ALLA TION Continued Figure 23 - Removing Log Base Assembly From Fireplace NOTICE: Most building codes do not permit con- cealed gas connections.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 15 15 INST ALLA TION Continued Figure 25 - Equipment Shutoff Valve ON POSITION OFF POSITION Open Closed Equipment Shutoff Valve Test Pressures Equal To or Less Than 1/2 PSIG (3.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 16 Notches Screws for Mounting Screen INST ALLA TION It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with fireplace.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 17 17 INST ALLA TION Continued INSTALLING BATTERIES FOR REMOTE RECEIVER AND HAND HELD REMOTE CONTROL Four AA batteries and three AAA batteries are required to operate this heater with the wireless hand-held remote control set.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 18 AUT O MAN OPERATING FIREPLACE Lighting Instructions (Cont.) To Turn Off Gas To Appliance Manual Lighting Procedure 1. STOP! R e a d t h e s afe t y i n fo rm a t i o n , page 17 column 2.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 19 19 HAND-HELD REMOTE OPERATION NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instruc- tions , pages 17 and 18.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 20 Figure 38 - Correct Pilot Flame Pattern Figure 39 - Incorrect Pilot Flame Pattern Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 3 8 shows a correct pilot flame pattern.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 21 21 CLEANING AND MAINTENANCE WARNING: Turn off fireplace and let cool before cleaning. CAUTION: You must keep control areas, burner, and circulating air passageways of fireplace clean.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 22 TROUBLESHOOTING TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and let cool before servicing. Only a qualified service person should service and repair heater.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 23 23 TROUBLESHOOTING TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pi.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 24 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 25 25 SPECIFICA TIONS LMFP33NR LMFP33PR Btu (Variable) 23,000/33,000 23,000/33,000 Type Gas Natural Gas Only Propane/LP Only Ignition Piezo Piezo Pressure Manifold 3.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 26 ILLUSTRA TED P ARTS BREAKDOWN MODELS LMFP33PR AND LMFP33NR (Shown) 17 27 4 O F F P I L O T O N 8.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 27 27 P ARTS LIST This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 28 ILLUSTRA TED PA R T S BREAKDOWN FIREBOX LMFP33PR AND LMFP33NR 4 11 14 8 14 9 3 14 9 9 2 1 6 7 10.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 29 29 P ARTS LIST FIREBOX LMFP33PR AND LMFP33NR This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 30 ACCESSORIES ACCESSORIES EQUIPMENT SHUTOFF VALVE - GA5010 For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe. Purchase these fireplace accessories from your local dealer.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 31 31 • ACCESSORIES 1. Where will the product be used? ❍ Living/F amily Room ❍ Office/W arehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other 2.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 32 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Postage Required T APE T APE.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 33 33 NOTES _______________________________________________________________________________________.
111604-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 34 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa LMFP33PR c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa LMFP33PR - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa LMFP33PR, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa LMFP33PR va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa LMFP33PR, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa LMFP33PR.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa LMFP33PR. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa LMFP33PR ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.