Manuel d'utilisation / d'entretien du produit CGP11A du fabricant Desa
Aller à la page of 28
Save this manual for future reference. VENT -FREE PROP ANE GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL Model: CGP1 1A WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 100846 CONTENTS SECTION PAGE Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ...................
3 100846 SAFETY INFORMA TION Continued WARNING ICON G 001 W ARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. Use only propane gas. Do not convert heater to use different fuel type. 2. Do not place propane supply tank(s) inside any structure.
4 100846 PRODUCT IDENTIFICA TION PRODUCT FEA TURES Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
5 100846 FRESH AIR FOR COMBUSTION AND VENTILA TION WARNING ICON G 001 W ARNING This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
6 100846 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued WARNING ICON G 001 W ARNING You must provide additional ventilation air in a confined space. DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
7 100846 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
8 100846 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR (Continued) Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor.
9 100846 INST ALLING T O W ALL NOTICE A qualified service person must install heater. Follow all local codes. Continued CHECK GAS TYPE Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.
10 100846 2. Mark two mounting screw locations on wall (see Figure 5). INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater.
11 100846 Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater. Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit.
12 100846 Placing Heater On Mounting Screws 1. Locate two keyhole slots on back panel of heater (see Figure 9). 2. Place large openings of slots over screwheads.
13 100846 CONNECTING T O GAS SUPPL Y NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure between 11 and 14 inches of water.
14 100846 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. Figure 13 - Gas Connection * An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection.
15 100846 3. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once.
16 100846 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above. 2. Make sure manual shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. A. This appliance has a pilot which must be lighted by hand.
17 100846 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety infor- mation at the top of page 16. If you don’t smell gas, go to the next step. 5. Press in control knob, and turn counterclockwise C-clockwise to pilot position.
18 100846 TO SELECT HEA TING LEVEL Figure 18 - Burner Patterns 1. Slightly press in control knob and turn counterclockwise C-clockwise to the LOW or HIGH positions. IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position.
19 100846 INSPECTING BURNER GRH/OV 007 GOOD PILOT/LP Thermocouple Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple.
20 100846 If burner flame pattern is incorrect, as shown in Figure 22 • turn heater off (see To Turn Off Gas to Appliance , page 19) • see Troubleshooting , pages 21 through 24 Figure 22 - Incorrect Burner Flame Pattern Figure 21 - Correct Burner Flame Pattern BURNER FLAME PATTERN Figure 21 shows a correct burner flame pattern.
21 100846 CLEANING AND MAINTENANCE WARNING ICON G 001 W ARNING Turn off heater and let cool before cleaning. Continued WARNING ICON G 001 CAUTION You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use.
22 100846 REMEDY 1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Contact local propane gas company 6.
23 100846 REMEDY 1. Clean burner orifice(s) (see Cleaning and Maintenance , page 21) or replace burner orifice(s) 2. Replace burner orifice(s) 3. Contact local propane gas company 1. Contact local propane gas company 2. Clean burner orifice(s) (see Cleaning and Maintenance , page 21) or replace burner orifice(s) 1.
24 100846 If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
25 100846 BTU (Variable) 5,500/11,000 Type Gas Propane Only Ignition Piezo Pressure Regulator Setting 8" W.C. Inlet Gas Pressure (inches of water) Maximum 14" Minimum 11" Dimensions, In.
26 100846 P ARTS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. SER VICE PUBLICA TIONS You can purchase a service manual from the address listed on the back page of this manual.
27 100846 P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa CGP11A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa CGP11A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa CGP11A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa CGP11A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa CGP11A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa CGP11A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa CGP11A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa CGP11A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.