Manuel d'utilisation / d'entretien du produit CGP10R du fabricant Desa
Aller à la page of 20
INFRARED VENT -FREE PR OP ANE/LP GAS HEA TER O WNER’S OPERA TION AND INST ALLA TION MANU AL Models: CGP10R and CGP10RL ® Save this manual for future reference. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 103548 GAS RESIDENTIAL HEA TERS SAFETY INFORMA TION W ARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, and carbon monoxide poisoning.
3 103548 OWNER’S MANUAL Heater Cabinet Grill Guard Burners Front Panel Figure 1 - Vent-Free Propane/LP Gas Heater Control Knob Piezo Ignitor Button PRODUCT IDENTIFICA TION Continued AIR FOR COMBUSTI.
4 103548 GAS RESIDENTIAL HEA TERS DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
5 103548 OWNER’S MANUAL Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 Figure 2 - Ve.
6 103548 GAS RESIDENTIAL HEA TERS 36" 3" FLOOR CEILING Minimum Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material 8" Minimum From Sides Of Heater Right Side Left Side Figure 4 - Mounting Clearances As Viewed From Front of Heater INST ALLING TO W ALL NOTICE: A qualified service per- son must install heater.
7 103548 OWNER’S MANUAL Mounting Screw Locations 10 7/8" Minimum To Maintain 6" Clearance From Wall 7 3/4" 20 1/4" Minimum To Maintain 3" Clearance From Floor FLOOR JOINING WALL INST ALLING TO W ALL Continued INSTALLING HEATER TO WALL Marking Screw Locations 1.
8 103548 GAS RESIDENTIAL HEA TERS IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/ or fittings. Figure 13 - Gas Connection * An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection.
9 103548 OWNER’S MANUAL CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections for leaks after installation or servicing. Correct all leaks at once WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
10 103548 GAS RESIDENTIAL HEA TERS OFF PILOT IGNITOR LOW HIGH T O SELECT HEA TING LEVEL 1. Slightly press in control knob and turn counter clockwise o the LO W or HIGH positions. IMPORT ANT : Release downward pressur e while turning contr ol knob . Control knob will lock at the desir ed position.
11 103548 OWNER’S MANUAL LOW OFF PILOT HIGH OFF PILOT OFF Control Knobs Burners Figure 18 - Burner Patterns OPERA TING HEA TER Continued T O TURN OFF GAS T O APPLIANCE Shutting Off Heater 1. T ur n control knob clockwise to the OFF position. Shutting Off Burner Only (pilot stays lit) 1.
12 103548 GAS RESIDENTIAL HEA TERS TROUBLESHOOTING Note: All Trouble Shooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/ pilot.
13 103548 OWNER’S MANUAL TROUBLESHOOTING Continued Continued REMEDY 1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 10 seconds 3. Fully open manual shut-of f valve 4. Hand tighten until snug, then tighten 1/4 turn more 5 .
14 103548 GAS RESIDENTIAL HEA TERS When gas pressure is too low • pilot will not stay lit • burner(s) will ha ve delayed ignition • heater will not produce specif ied heat • propane/LP gas supply may be lo w TROUBLESHOOTING Continued TECHNICAL SER VICE You may have further questions about in- stallation, operation, or Trouble Shooting.
15 103548 OWNER’S MANUAL CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person.
16 103548 GAS RESIDENTIAL HEA TERS ILLUSTRA TED PA R T S BREAKDOWN CGP10R CGP10RL 23 GRH VP11A GRH VP11A 21 20 19 18 17 14 15 16 13 10 12 9 9 11 22 7 8 6 6 5 4 3 2 1 A B 23 24 25 GRH VP11A GRH VP11A GRHpv013.
17 103548 OWNER’S MANUAL P ARTS LIST CGP10R CGP10RL This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY.
18 103548 GAS RESIDENTIAL HEA TERS NOTES _______________________________________________________________________________________________ _______________________________________________________________.
19 103548 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
KEEP THIS WARRANTY W ARRANTY INFORMA TION 103548-01 REV. A 03/97 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 DESA International warrants this product to be free from defects in m.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa CGP10R c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa CGP10R - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa CGP10R, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa CGP10R va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa CGP10R, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa CGP10R.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa CGP10R. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa CGP10R ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.