Manuel d'utilisation / d'entretien du produit CGP10A du fabricant Desa
Aller à la page of 20
Save this manual for future reference. BLUE FLAME VENT -FREE PROP ANE/LP GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL MODELS: CGP10A AND CGP6 ® WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 101871 PROP ANE/LP GAS HEA TER CGP10A AND CGP6 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not con vertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure.
3 101871 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
4 101871 PROP ANE/LP GAS HEA TER CGP10A AND CGP6 WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide ad- equate combustion and ventila- tion air by one of the methods described in the National Fuel Gas Code, ANSI Z223.
5 101871 OWNER’S MANUAL FRESH AIR FOR COMBUSTION AND VENTILA TION Continued Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilatio.
6 101871 PROP ANE/LP GAS HEA TER CGP10A AND CGP6 For convenience and efficiency, install heater • where there is easy access for opera- tion, inspection, and service • in coldest part of room Figure 4 - Mounting Clearances As Viewed From Front of Heater INSTALLING HEATER TO WALL Marking Screw Locations 1.
7 101871 OWNER’S MANUAL Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater. Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit.
8 101871 PROP ANE/LP GAS HEA TER CGP10A AND CGP6 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/ or fittings. Figure 13 - Gas Connection Tee Joint Reducer Bushing .
9 101871 OWNER’S MANUAL CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections for leaks after installation or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
10 101871 PROP ANE/LP GAS HEA TER CGP10A AND CGP6 TO TURN OFF GAS TO APPLIANCE 1. Remove fr ont panel (see Figure 10, page 12). 2. Follow steps 1 thr ough 5 under Light- ing Instructions . 3. With contr ol knob pr essed in, str ike match. Hold match to pilot until pi- lot lights.
11 101871 OWNER’S MANUAL BURNER FLAME PATTERN Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.
12 101871 PROP ANE/LP GAS HEA TER CGP10A AND CGP6 Continued Note: All troubleshooting items are listed in order of operation. TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
13 101871 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smo.
14 101871 PROP ANE/LP GAS HEA TER CGP10A AND CGP6 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
15 101871 OWNER’S MANUAL MANUAL SHUTOFF VALVE - GA5010 Manual shutoff valve with 1/8" NPT tap. ACCESSOR Y Purchase this heater accessory from your local dealer.
16 101871 PROP ANE/LP GAS HEA TER CGP10A AND CGP6 12-2 12-1 ODS/PILOT 10 12 11 1 2 3 4 5 6 7 9 8 GRHpv014C CGP10 10 13 14 15 16 17 18 21 23 24 27 22 26 25 19 20 28 29 HEATER EXPLODED VIEW ILLUSTRA TED.
17 101871 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual. PART NUMBER FOR CGP6 CGP10A KEY NO. DESCRIPTION QTY.
18 101871 PROP ANE/LP GAS HEA TER CGP10A AND CGP6 These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department Portable Heater Parts 342 N.
19 101871 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa CGP10A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa CGP10A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa CGP10A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa CGP10A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa CGP10A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa CGP10A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa CGP10A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa CGP10A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.