POR T ABLE FORCED AIR HEA TER OWNER’S MANUAL Model BY150ECB 150,000 Btu/Hr 110v/50 Hz IMPORTANT Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
2 104001 POR T ABLE FORCED AIR HEA TER MODEL BY150ECB 150,000 Btu/Hr • Use only kerosene or No. 1 fuel oil to av oid risk of fire or explosion. Ne ver use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fu- els.
3 104001 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Model BY150ECB These models are furnished with wheels and a front handle. Some models are furnished with a rear handle also. Wheels, handle(s), and the mounting hardware are found in the shipping carton.
4 104001 POR T ABLE FORCED AIR HEA TER MODEL BY150ECB 150,000 Btu/Hr VENTILA TION WARNING: Follow the mini- mum fresh, outside air ventila- tion requirements. If proper fresh, outside air ventilation is not pro- vided, carbon monoxide poison- ing can occur.
5 104001 OWNER’S MANUAL Figure 4 - Flame-Out Control Reset Button Extension Cord Wire Size Requirements Up to 30.5 meters (100 feet) long, use 1.0 mm 2 (16 A WG) conductor 30.6 to 61 meters (101 to 200 feet) long, use 1.5 mm 2 (14 A WG) conductor Push ON/OFF switch to ON and heater should start.
6 104001 POR T ABLE FORCED AIR HEA TER MODEL BY150ECB 150,000 Btu/Hr TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operating, or hot.
7 104001 OWNER’S MANUAL SER VICE PROCEDURES UPPER SHELL REMOVAL 1. Remov e screws along each side of heater using 5/16" nut-dri ver . These screws attach upper and lo wer shells together . 2. Lift upper shell off. 3. Remov e fan guard. FAN IMPORTANT: Remove fan from motor shaft before removing motor from heater.
8 104001 POR T ABLE FORCED AIR HEA TER MODEL BY150ECB 150,000 Btu/Hr FUEL FILTER 1. Remov e side cover scre ws using 5/16" nut-dri ver . 2. Remov e side cover . 3. Pull upper fuel line off fuel filter neck. 4. Carefully pry bushing, fuel filter , and lower fuel line out of fuel tank.
9 104001 OWNER’S MANUAL PUMP ROTOR (Procedure if rotor is binding) 1. Remov e upper shell (see page 7). 2. Remov e filter end cover scre ws using 5/16" nut-dri ver . 3. Remov e filter end co ver and air filters. 4. Remov e pump plate screws using 5/16" nut-dri ver .
10 104001 POR T ABLE FORCED AIR HEA TER MODEL BY150ECB 150,000 Btu/Hr Power Plug 110V/50Hz Brown Blue Spark Plug On/Off Switch Flame-Out Control B B C D A Reset Button R 1 1a Blue Photocell Blue White.
11 104001 OWNER’S MANUAL KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 HA2204 Handles 2 2 M12345-33 Screw, #10-24 x 1 3/4" 8 3 M12831-3 Wheel Support Frame 1 4 NTC-3C Hex Nut, #10-24 8 5 097896-0.
12 104001 POR T ABLE FORCED AIR HEA TER MODEL BY150ECB 150,000 Btu/Hr 1 2 3 4 6 5 7 23 11 9 10 16 25 27 24 28 20 22 21 30 31 40 32 33 34 41 35 36 17 18 37 38 43 26 44 45 46 29 49 48 47 12 15 39 8 19 1.
13 104001 OWNER’S MANUAL This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. ** Not available as an assembly.
14 104001 POR T ABLE FORCED AIR HEA TER MODEL BY150ECB 150,000 Btu/Hr EC CONFORMITY DECLARA TION EC CONFORMITY DECLARATION SGB YOUNGMAN Stanestreet, Slingfold, Horsham West Sussex Rh13 7RD United Kingdom (UK) Manufacturer: DESA International, Inc. 2701 Industrial Drive Bowling Green, KY 42101 U.
15 104001 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
W ARRANTY AND REP AIR SERVICE 104001-01 Rev. A 7/97 SGB YOUNGMAN warrants new Products sold by it to be free from defects in material or workmanship for a period of 360 days after date of delivery to .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa 10BY150ECB c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa 10BY150ECB - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa 10BY150ECB, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa 10BY150ECB va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa 10BY150ECB, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa 10BY150ECB.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa 10BY150ECB. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa 10BY150ECB ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.