INSTALLATION MANUAL R410A Split Series Models 2MXS40G2V1B 2MKS40G2V1B 2MXS40H2V1B 2MKS40H2V1B 2MXS40H3V1B 2MKS50G2V1B 2MXS50G2V1B 2MKS50H2V1B 2MXS50H2V1B 2MXS50H3V1B 2AMX40F2V1B 2AMX40G2V1B 2AMX40G3V1.
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan 3SB64417-5A 2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B, 2AMX40G2V1B, 2AMX50G2V1B, 2AMX40F2V1B, 2AMX50F2V1B, 2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B 2MXS40H2V1B, 2MXS50H2V1B, 2MKS40H2V1B, 2MKS50H2V1B D AIKIN INDUSTRIES, L TD.
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan D AIKIN INDUSTRIES, L TD. EN60335-2-40, DAIKIN.TCF .015 P6/07-2012 DEKRA Certification B.
3SB65451-4.fm Page 2 Thursd ay, October 27, 2011 4:49 PM.
1 ■ English Safety Precautions • The precautions descri bed herein are classified as W ARN ING and CAUTION. They both contain important informa - tion regarding safety . Be sure to observe all precau tions without fail. • Meaning of W ARNING and CAUTION no tices W ARN ING .
■ English 2 Accessories Accessories supplied wit h the outdoor unit: Precautions for Selecting the Location 1) Choose a place soli d enough to bear th e weight and vibratio n of the uni t, where the operation noi se will not be ampli fied.
3 ■ English Indoor/Outdoor Unit Installation Drawings For installation of the indoor units, refer to the insta llation manual which was provided with the units.
■ English 4 Installation • Install the unit horizontally . • The unit may be installed directly on a concrete verandah or a solid place if drai nage is good. • If the vibration may possibly be transmitted to the bu ilding, use a vibration-pr oof rubbe r (field supply).
5 ■ English Outdoor Unit Installation Guideline • Where a wall or other obstacle is in the path of outdoor unit’s inlet or outlet airflow , follow the instal lation guidelines be low . • For any of the below installation pattern s, the wall height on the exhaust side should be 120 0mm or less.
■ English 6 Refrigerant Piping W ork 1. Installing outdoor unit 1) When installing the outdoor unit, refer to “Precautions for Se lecting the Location” on page 2 and the “Indoor/Outdoor Unit Installation Drawings” on p age 3. 2) If drain work is ne cessary , follow the procedures below .
7 ■ English Refrigerant Piping W ork 4. Purging air and ch ecking gas leakage WARNING • Do not mix any substance other tha n the specifie d refrigerant (R410A) into the refrigera tion cycle. • When refrigerant gas leaks occur , ventilate the room as soon and as much as possible.
■ English 8 5. Refilling the refrigerant Check the type of refrigerant to be used on the machine nameplate. Precautions when adding R410 A Fill from th e gas pipe i n liquid form. It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, p reventing normal operatio n.
9 ■ English Refrigerant Piping W ork Precautions for Laying Refrigerant Piping • Cautions on pipe handling 1) Protect the open end of the pipe against du st and moisture. 2) All pipe bends should be as gentle as possible. Use a pipe bender for bending.
■ English 10 Pump Down Operation In order to protect the environment, be sure to pump down when relocating or disposing of the unit. 1) Remove the valve cap s on the liquid an d the gas stop valves at the pipes for rooms A and B. 2) Run the unit on forced cooling.
11 ■ English Wir ing WARNING • Do not use tapped wire s, stranded wires ( CAUTION 1)), extension co rds, or starburst co nnections, as they may cau se over- heating, electrical shock, or fire. • Do not use locally purchased electrical parts inside the produc t.
■ English 12 Maximum Power Input Limitation Setting WARNING Always shut off the power supply breaker before starting. • The Maximum Power Input Limitation needs to be set when the unit is installed. • This function limi ts the power input of the unit to 1700W .
13 ■ English ECONO Mode Prohibition Setting WARNING Always shut off the power supply breaker before starting. • This setting disables the inp ut control signal from the remote controller . • Use this setting when you wish to block receptio n of input controls (cooling/heating) from indoor unit remote co ntrollers.
■ English 14 T rial Operation and T esting • Before starting the test run, measure the voltag e at the primary side of the safety breaker . • Check that all liquid and gas stop valves are fully open. • Check that pipi ng and wiring all match. 1.
(1210) HT 3P210724-1F M07B062F Two-dimensio nal bar code is a code for manufact uring. 00_CV_3P210724-1F.fm Page 2 Tu esday, October 30, 2012 10: 36 AM.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Daikin 2AMX50G3V1B c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Daikin 2AMX50G3V1B - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Daikin 2AMX50G3V1B, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Daikin 2AMX50G3V1B va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Daikin 2AMX50G3V1B, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Daikin 2AMX50G3V1B.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Daikin 2AMX50G3V1B. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Daikin 2AMX50G3V1B ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.