Manuel d'utilisation / d'entretien du produit SQC Pro du fabricant Cuno
Aller à la page of 15
© 2001 CUNO Incorporated 98-91220 0601 CUNO Incorporated 400 Research Parkway Meriden, CT 06450, U.S.A. Toll Free: 1-800-733-1199 Worldwide: 203-237-5541 Fax: 203-238-8701 www.
INTRODUCTION This manual explains the installation, operation and maintenance of the Water Factory Systems ® SQC Series Reverse Osmosis (RO) Drinking Water Appliances. Please read each section of this manual care - fully. The specific model chosen should be appropriate for the local water conditions and the customer's needs.
A. DETERMINE THE APPLIANCE LOCATION The appliance can be located under a sink or in a basement depending on space availability and the customer's preference. If a basement installation is selected, additional tubing, hardware and fittings may be needed and a hole will have to be made from inside the cabinet, through the floor, to the basement.
C. PREPARE THE APPLIANCE FOR INSTALLATION Open the shipping carton and remove the components. Check to see that all of the installation parts are present. They should include the purification assembly, storage tank, faucet, installation hardware, RO membrane cartridge and tubing.
E. MOUNT THE FAUCET Undercounter installations generally require that the faucet's built-in air gap be used. In basement installations, the built-in air gap does not have to be used if one is provided elsewhere on the drain line. For Basement Installations Without An Air Gap Module See Installation Instructions O.
F . INSTALL THE FEED WATER TAPPING VALVE AND TUBING The feed water tapping valve which is supplied, is designed to be used on 3/8" to 1/2" OD soft copper tubing (plain or chromed) and rigid metal pipe. Do not use it on flexi - ble ribbed tubing, because it has too thin a wall thickness and it requires special hardware.
5) Turn the feedwater tapping valve handle clockwise to close the valve. With a wrench, tighten the nut/seal around the valve handle stem. 6) Remove the cover from the appliance and disconnect the orange 1/4" tubing from the feedwater fitting. (See Fig.
I. INSTALL THE PURIFICATION ASSEMBLY AND STORAGE TANK For Basement Installation See Installation Instructions O. Undercounter Installation: The purification assembly is usually mounted to the right or the left side wall inside of the sink cabinet, taking into consider - ation the space available and the tank location.
L. START UP THE APPLIANCE 1) Double check to see that all of the connections are secure. 2) Open the feedwater tapping valve and check the appliance for leaks. If any leaks are detected, close the valve and correct the problem before proceeding. NOTE: If a leak occurs at a "Push In" plastic fitting, then refer to Fig.
O. APPENDIX FOR BASEMENT INSTALLATIONS The following variations are generally required for basement installations: INSTALL THE DRAIN CONNECTION For basement installations, the drain saddle is generally not used.
Teflon is a registered trademark of E.I. DuPont 11 P. INSTALLATION TROUBLESHOOTING Problem: Leak at the feedwater tapping valve. Cause: Tapping valve is not clamped tightly enough. Solution: Tighten the tapping valve clamp screws evenly and firmly keeping both halves of the bracket parallel.
A. IMPORTANT WATER QUALITY ASSURANCE REQUIREMENTS Reverse Osmosis drinking water appliances contain treat - ment components that are critical for the effective reduction of Total Dissolved Solids (TDS) as well as inorganic chemical contaminants.
C. REPLACING THE RO MEMBRANE CARTRIDGE The life of the RO membrane cartridge depends on the local water conditions and proper maintenance, e.g., regular fil - ter changes.
4) Fill the sanitizing device with the following recommended dosage of common household bleach: • A standard 2.5 gallon tank - 1/2 teaspoon (3 ml) • Alternate size tanks - 1/2 teaspoon (3 ml) per 2.5 gallons of tank capacity 5) Open the feedwater tapping valve to force water and sanitizer into the storage tank.
Appendix 1. Electrical Diagram 15.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Cuno SQC Pro c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Cuno SQC Pro - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Cuno SQC Pro, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Cuno SQC Pro va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Cuno SQC Pro, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Cuno SQC Pro.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Cuno SQC Pro. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Cuno SQC Pro ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.