Vault w/ visor C-Scroll w/ visor Roundel w/ visor These installation instructions are valid with the above Ametrix styles

Cooper Lighting CPP/CPS diagram (page 1)
Fig. 2
Page 2 of the Cooper Lighting CPP/CPS user manual
Page 2 · cliquer pour agrandir
Page 2

Vault w/ visor C-Scroll w/ visor Roundel w/ visor These installation instructions are valid with the above Ametrix styles.

#8-32 x1/2" Screw (2x)

#8-32 x1/2" Screw (2x)

#10-32 x5/8" End Screw

#10-32 x5/8" End screw

1. Secure pendant yoke to pendant tube using both pendant nuts prior to installation.
1. Secure pendant yoke to pendant tube using both pendant nuts prior to installation.

Mounting power-side pendant to J-box

Mounting non power side pendant

Run wiring into pendant tube

(2x) Screw (by others)

#8-32 x1/2" Screw (2x)

These instructions are valid for both PP and PS mounting assemblies. Secure both pendant assemblies to ceiling before attaching fixture head.

These instructions are valid for both PP and PS mounting assemblies

1. Remove canopy and allow it to slide down pendant. 2. Refer to power orientation supplementary sheet for power location. 3. Run wiring from j-box down pendant tube and using #8-32 x1/2" Pan head screws, secure mounting plate to j-box. Reinforce J-box with additional bracing.
1. To secure non-power pendant, remove canopy and allow it to slide down pendant. 2. Replace #8 Pan head screws with appropriate fasteners(by others) Use additional bracing to secure pendant. 3. Secure mounting plate on center using dimensions provided on next page.
Cooper Lighting CPP/CPS diagram (page 2)
Fig. 3
Show 15 more labels / short text on this page
PP Exploded assembly · PS Exploded assembly · PP mounting plate · PS mounting plate · PP canopy · PS canopy · Pendant yoke · Pendant yoke · Pendant nut · Pendant nut · PS mounting plate · #8-32 x1/2" J-box · plate PS mounting · Canopy · Canopy
Page 3 of the Cooper Lighting CPP/CPS user manual
Page 3 · cliquer pour agrandir
Page 3
Cooper Lighting CPP/CPS diagram (page 3)
Fig. 4

Vault w/ visor C-Scroll w/ visor Roundel w/ visor These installation instructions are valid with the above Ametrix styles

Page 4 of the Cooper Lighting CPP/CPS user manual — Securing additional fixtures in run
Page 4 · cliquer pour agrandir
Page 4

Vault w/ visor C-Scroll w/ visor Roundel w/ visor These installation instructions are valid with the above Ametrix styles.

3 Securing first fixture to wired center yoke

Securing first fixture to first pendant

bracket

Fixture wire Power wire from J-box

#10-32 x 5/8 End screw

#10-32 x5/8 End screw

#6-32 x 3/8" Pan head screws

1. Remove both #6-32 x3/8" Pan head screws and slide center cover plate down. 2. Run power wire from fixture through hub and into center yoke bracket. 3. Secure first fixture to center yoke bracket using #10-32 x5/8" end screw.
1. Choose first fixture in run. First fixture depends on length of run, refer to page four(4) for fixture identification. The final fixture will have to have the extra wire capped off. 2. Secure fixture head to pendant assembly using #10-32x 5/8" end screw.

Securing additional fixtures in run

Wiring fixtures to J-box

Power wire from J-box

#10-32 x 5/8" End screw Center cover plate

Fixture wire Fixture wire

1. Mount next center or end pendant depending on length of run. 2. Run new fixture wire into center yoke bracket. 3. Using #10-32 x5/8" end screws, secure new fixture head to both pendants.
1. Attach wires and ensure connections are properly matched. (wire nuts by others) 2. Replace center cover plate and secure using both #6-32 x 3/8" Pan head screws.
Cooper Lighting CPP/CPS — Securing additional fixtures in run diagram (page 4)
Fig. 5 · Securing additional fixtures in run
Show 6 more labels / short text on this page
Fixture wire · Canopy · First fixture head · Center cover plate · Fixture wire · Center cover plate
Page 5 of the Cooper Lighting CPP/CPS user manual — Continuous Pendant Row Layouts
Page 5 · cliquer pour agrandir
Page 5

Vault w/ visor C-Scroll w/ visor Roundel w/ visor These installation instructions are valid with the above Ametrix styles

Continuous Pendant Row Layouts

Nominal Row Length (ft)Actual Overall Row Length: Pendant (ft)Row Breakdown/ Installation Sequence 32.62C 43.63C 54.64C 65.12C,2C 76.12C,3C 87.13C,3C 98.13C,4C 109.14C,4C 1110.73C,3C,3C 1211.74C,2C,4C 1312.74C,3C,4C 1413.74C,4C,4C 1514.23C,3C,3C,3C 1615.23C,3C,3C,4C 1716.23C,4C,4C,3C 1817.24C,4C,4C,3C 1918.24C,4C,4C,4C 2019.84C,3C,3C,3C,4C 2120.83C,4C,4C,4C,3C 2221.84C,4C,3C,4C,4C 2321.84C,4C,3C,4C,4C 2423.42C,4C,4C,4C,4C,2C 2523.42C,4C,4C,4C,4C,2C 2625.43C,4C,4C,4C,4C,3C
Nominal Row Length (ft)Actual Overall Row Length: Pendant (ft)Row Breakdown/ Installation Sequence 2725.43C,4C,4C,4C,4C,3C 2827.44C,4C,4C,4C,4C,4C 2928.94C,4C,3C,3C,3C,4C,4C 3029.93C,4C,4C,4C,4C,4C,3C 3130.94C,4C,4C,3C,4C,4C,4C 3231.94C,4C,4C,4C,4C,4C,4C 3331.94C,4C,4C,4C,4C,4C,4C 3432.52C,4C,4C,4C,4C,4C,4C,2C 3534.53C,4C,4C,4C,4C,4C,4C,3C 3635.54C,4C,4C,4C,3C,4C,4C,4C 3736.54C,4C,4C,4C,4C,4C,4C,4C 3838.04C,4C,4C,3C,3C,3C,4C,4C,4C 3939.03C,4C,4C,4C,4C,4C,4C,4C,3C 4039.03C,4C,4C,4C,4C,4C,4C,4C,3C 4140.04C,4C,4C,4C,3C,4C,4C,4C,4C 4241.04C,4C,4C,4C,4C,4C,4C,4C,4C 4342.64C,4C,4C,4C,3C,3C,3C,4C,4C,4C 4443.63C,4C,4C,4C,4C,4C,4C,4C,4C,3C 4544.64C,4C,4C,4C,4C,3C,4C,4C,4C 4645.64C,4C,4C,4C,4C,4C,4C,4C,4C,4C 4746.13C,3C,4C,4C,4C,4C,4C,4C,4C,3C,3C 4847.14C,4C,4C,4C,3C,3C,3C,4C,4C,4C,4C 4948.13C,4C,4C,4C,4C,4C,4C,4C,4C,4C,3C 5049.14C,4C,4C,4C,4C,3C,4C,4C,4C,4C,4C

(Custom row configurations are available however pricing may be affected)

Cooper Lighting CPP/CPS — Continuous Pendant Row Layouts diagram (page 5)
Fig. 6 · Continuous Pendant Row Layouts

Poser une question sur : Cooper Lighting CPP/CPS

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Cooper Lighting CPP/CPS

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Cooper Lighting CPP/CPS manuel PDF

5 pages·828 KB·Mobilier d'intérieur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…