Accor d Series T5/T8 Enhanced Lighting System.
1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual Perception 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Comparison 7 . . . . .
2 Improve visual perception • The accord TM evenly distributes light, making the space more pleasing to the eye. • Dark spots (cave effect) associated with parabolics are eliminated. Attractive design • Smooth, cur ved surfaces are attractive but subtle.
Parabolics are designed to direct light into the cut-off zone, while restricting light into the shielded or glare zone. In other words, parabolics deliver light to the work plane and suppress high-angle brightness. Due to the high-angle cutoffs as shown in Figure 1.
SHIELDED ZONE CUT -OFF ZONE 85˚ 75˚ 65˚ 55˚ Figure 1. Parabolic Light Distribution MINIMIZED SHIELDED ZONE ENHANCED CUT -OFF ZONE 85˚ 75˚ 65˚ 55˚ Figure 2. accord TM Light Distribution Attractive contemporary design • Smooth, cur ved surfaces are attractive but subtle.
accord TM 2 Lamp, T5 accord TM (2) 28W T5 lamps, 18 fixtures step-dim electronic ballast (.95 ballast factor) 63 watts per fixture Watts/Sq.ft. Horizontal Footcandles Vertical Footcandles 0.76 41 25 IES* accord TM maximizes savings Choose either T5 or T8 technology to best meet your lighting needs.
T roffer 4 Lamp T ypical 4 lamp troffer (4) 32W T8 lamps, 12 fixtures electronic ballast (.87 ballast factor) 122 watts per fixture Watts/Sq.ft. Horizontal Footcandles Vertical Footcandles 0.98 50 23 IES* accord TM 2 Lamp, T8 accord TM (2) 32W T8 lamps, 12 fixtures electronic ballast (1.
Appearance and performance make accord TM the lighting choice. Energy savings makes accord TM a sound financial decision. The accord TM family of products saves up to 40% energy costs when compared to a standard 3 lamp,18 cell parabolic. The dimming feature reduces energy consumption by another 50%.
COST PER kWh Hours of Oper ation $0.06 $0.08 $0.1 0 $0.1 2 $0.1 4 P er Day P er Y ear 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 12 hrs. 4,380 $16.03 $7.88 $21.37 $10.51 $26.72 $13.14 $32.06 $15.76 $37.41 $18.36 18 hrs. 6,570 $24.04 $1 1.
• 3-13/16" low profile housing Surface Mount av ailable Low profile and quality performance – the surface accord TM is an energy efficient alternative to traditional surface mount fixtures. Designed for areas without a grid-ceiling type system, the accord’ s TM low profile is an ideal retro-fit solution.
Diffuser Options Square Perf Design (SQP) Smooth acrylic diffuser with square perforated insert (2' x 2', 2' x 4' only) Round Perf Design (RPD) Smooth acrylic diffuser with round p.
accord TM - 1' x 4', T5 accord TM - 1' x 4', T8 Candlepower Angle Along II 45° Across ⊥ 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 AC-128T5 Electronic Ballast (1) F28T5/835 Lamp 260 0 Lumens Spacing criterion: (II) 1 .
accord TM - 2' x 2', T5 accord TM - 2' x 2', T8 Candlepower Angle Along II 45° Across ⊥ 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 2AC-214T5 Electronic Ballast (2) F14T5/835 Lamps 1350 Lumens Spacing criterion: (II) 1 .
T5 Ordering Information SAMPLE NUMBER: 2AC-228T5-UNV-L5841-EBT1NDIM-U Number of Lamps (Not included) 1 =1 Lamp (1' x 4' only) 2 =2 Lamp (2' x 2', 2' x 4' only) W attage (.
• The accord TM can provide up to 40% energy savings when compared to a 3 lamp, 18 cell, T8 parabolic. • The accord TM also exceeds mandated energy regulations such as California’ s Titl e 24 and ASHRAE 90.1 2001. • Step dimming can increase energy s av ings by as much as 50%.
Printed in USA ADF080670 Cooper Industries, Ltd. 600 T ravis, Ste. 5800 Houston, TX 77002-1001 P: 713-209-8400 www .cooperindustries.com Cooper Lighting and Metalux logos are valuable trademarks of Cooper Industries in the United States and other countries.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Cooper Lighting Accord Series c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Cooper Lighting Accord Series - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Cooper Lighting Accord Series, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Cooper Lighting Accord Series va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Cooper Lighting Accord Series, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Cooper Lighting Accord Series.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Cooper Lighting Accord Series. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Cooper Lighting Accord Series ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.