The STN Series is a functional and multi-purpose medium duty strip family that incorporates premium performance and construction durability. The performance and application versatility of this series can be increased by incorporating symmetrical or asymmetrical reflectors. The STN Series can be installed using various mounting methods and numerous options and accessories are available.

The STN Series can be the illumination solution in commercial, industrial, retail and residential applications. Fixtures can be used in storage/utility areas, coves, display cases, shops, task and general area lighting.

A ... Construction Channel die formed code gauge prime cold rolled steel. Deep V-Groove for tong hanger. Die formed channel connector, sleeve type, assures straight rows and continuity of ground through set screws. Numerous KOs for ease of installation. Lampholder mounting brackets easily installed with snap-in action. Channel/wireway cover secured with quarter-turn fasteners.
B ... Electrical* Ballasts are CBM/ETL Class "P" and are positively secured by mounting bolts. Spring loaded lampholders. UL/CUL listed. Suitable for damp locations.
D ... Channel/Wireway Cover Die formed heavy gauge steel. Tight fit for ease of maintenance. Easily removed without use of tools. Optional reflector available incorporating silver technology enhancements. (SilverLining) Consult Pre Sales Technical Support.
C ... Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibitor. Lighting grade, baked white enamel finish.
140 132 240 232

7/8" K.O. (5)
11/16" x 1" K.O. (2)
7/32" x 3/8" K.O. (4)

11/16" x 1" K.O. (2)
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00
*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.
12/11/2007 7:51:43 AM Consult your representative for additional options and finishes. Specifications and Dimensions subject to change without notice. ADF020715

PHOTOMETRICS
Coefficients of Utilization
Candela
Effective floor cavity reflectance 20% rc 80% 70% 50% 30% 10% 0%
Angle Along II 45o Across⊥ 0
1009 1009 1009 996 1001 1009
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR
942 979 1014 853 945 1026 735 898 1008
107 102 93 93 93 85 85 85 78 78 78 75 95 90 86 81 91 86 82 78 79 75 72 72 69 67 65 63 61 58
86 77 70 64 81 74 67 62 67 62 58 61 57 53 56 53 50 46 78 67 59 52 74 64 57 51 59 53 47 54 49 44 49 45 41 38 71 59 50 44 67 56 48 42 52 45 40 47 42 37 43 38 35 32
593 823 959 432 721 906
260 633 824 100 460 600 9 248 381
64 52 43 36 61 49 41 35 45 38 33 41 35 31 38 33 29 26 59 46 37 31 56 44 36 30 40 33 28 37 31 26 34 29 25 22 54 41 32 26 51 39 31 26 36 29 24 33 27 23 30 25 21 19
7 336 527 7 255 448 7 211 364
50 37 28 23 47 35 27 22 32 26 21 30 24 19 27 22 18 16
46 33 25 19 43 31 24 19 29 22 18 27 21 17 24 19 16 14 43 30 22 17 40 29 21 17 26 20 16 24 19 15 22 17 14 12
7 142 276 7 76 175
7 18 79 7 5 5 0
Zone Lumens %Lamp %Fixture
822 14.4 15.4 1397 24.5 26.2 2724 47.8 51.1 4250 74.6 79.8 1078 18.9 20.2 5328 93.5 100.0
0-40 0-60 0-90 90-180
Test Report: STN232.IES
LER = FS-80
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00
S A M P L E N U M B E R : ST N - 2 3 2 - 1 2 0 V- E B 8 1- U

Options RIF1=Radio Interference Suppressor 6-3/18 SJT-C&P-515P=Cord & Plug (120V) 6-3/18 SJT-C&P-L715P= Cord & Plug (277V) PI/CPI=Plug-In Option L715P=Cord & Plug (277V) TILW=Tandem In-Line Wiring Option (Consult TILW Option Catalog Page) (See options & accessories)
Number of Lamps 1 or 2 lamps (Not Included)
Packaging U=Unit Pack 4B=4 Bulk
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast 1, 2 or 3
Wattage (Length) 40=34/40W T12 (48") 32=32W T8 (48")
EB8 /PLUS=T8 Electronic Instant Start.
High Ballast Factor >1.13. Total Harmonic Distortion < 20%
No. of Ballast 1, 2 or 3
120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (2)
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast 1 or 2
EB2 =T12 Electronic Rapid Start.
No. of Ballast 1 or 2
Options GL=Single Element Fuse GM=Double Element Fuse Emergency=EM Installed
DLS=Digital Lighting System Dimming
GRP-STN=Gripper Hanger (Use 2 Per Fixture) AYC-Chain/Set=36" Chain Hanger (Use 1 Set Per Fixture) SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) ATG-4=Tong Hanger (Use 2 Per Fixture) DI2=Long Connector STN/SS-ASY-3(3)=3" Asymmetric Reflector (Specify 2', 3', or 4')
STN/SS-ASY/REV-3(3)=3" Asymmetric Reverse Reflector
Catalog No. Wt.
(Specify 2', 3', or 4')
STN-132 12 lbs. 8TSTN-132 20 lbs. STN-232 12 lbs. 8TSTN-232 24 lbs.
STN/SS-SYM-6(3)=6" Symmetric Reflector (Specify 2', 3', or 4') STN/SS-ASY-6(3)=6" Asymmetric Reflector (Specify 2', 3', or 4') IC-4FT-REFL(3)=12" Symmetric Reflector WG/SS-4FT=Wire Guard
(Additional Accessories Available. See Options and Accessories Section.)