Manuel d'utilisation / d'entretien du produit DX20i MkII du fabricant Charnwood
Aller à la page of 11
Operating and Installation Instructions CHARNWOOD DX20i MkII Multifuel Roomheater Bishops Way, Newport, Isle Of Wight, PO3O 5WS, U.K. Tel: (01983) 537799 Fax: (01983) 537788.
GENERAL POINTS Before lighting the fire check with the installer that the work and checks described in the installation instructions have been carried out correctly and that the chimney has been swept, is sound, and free from any obstructions.
Open the main doors Open the ashpit door Close the ashpit door Close the main doors MULTIFUEL GRATE Your Charnwood is fitted with a multifuel grate which enables solid fuel, wood and peat to be burned equally effectively. The grate has two positions. One for solid fuel, the other for wood and peat.
For safety reasons, if the fire is to be left unattended with the doors open then use a spark guard which complies with BS 3248. ASH CLEARANCE The ashpan must be emptied regularly before it becomes too full. The most convenient time to remove the ash is just before riddling the fire since the ash will then be at it’s coolest.
THROAT PLATE AND FLUEWAY CLEANING It is important that the throat plate and all the appliance flueways are kept clean. When burning smokeless fuels they should be cleaned monthly. When burning other fuels they should be cleaned at least once a week, and more frequently if necessary.
Fire Blazing Out Of Control. Check that: a) the doors are tightly closed, b) the thermostat knob is turned down to the minimum setting, c) the air inlet damper is closed (at the bottom left of the app.
HEALTH AND SAFETY PRECAUTIONS WARNING Please take care when installing the appliance that the requirements of the Health and Safety at Work Act 1974 are met. Some types of fire cement are caustic and should not be allowed to come into contact with the skin.
output sufficient for domestic hot water heating. If the boiler is fitted then the room heating will be reduced. The hot water system should be a gravity circuit and must be correctly vented as shown in Fig. 6. A double feed indirect hot water appliance.
same side as the boiler tappings. One of the original side firebricks is fitted on the other side, and the rear firebrick is discarded. The firebricks must be fire cemented into position, wetting the firebox will improve the adhesion. Replace the back fireplate, the side fireplates, the front firebar and the throat plate.
The free inset method of installation may be used instead of infilling. Details are available on request. THERMOSTAT Before lighting the fire check the cold setting distance of the thermostat. With the control knob at the minimum setting the flap should be just closed as shown in Fig.
1 5 0 º 5 0 6 2 6 5 4 0 5 1 2 0 2 6 0 2 0 0 5 4 7 i / d 4 0 0 2 6 0 1 5 0 8 4 6 0 4 6 2 0 O p t i o n a l B o il e r M a y B e F i tt e d W i t h T h e1 " B .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Charnwood DX20i MkII c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Charnwood DX20i MkII - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Charnwood DX20i MkII, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Charnwood DX20i MkII va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Charnwood DX20i MkII, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Charnwood DX20i MkII.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Charnwood DX20i MkII. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Charnwood DX20i MkII ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.