Page 1 of the Chamberlain 3885C user manual — Owner's Manual
Page 1 · cliquer pour agrandir
Page 1

The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com

Chamberlain 3885C — Owner's Manual diagram (page 1)
Fig. 1 · Owner's Manual
Chamberlain 3885C — Owner's Manual diagram (page 1)
Fig. 2 · Owner's Manual
  • Please read this manual and the enclosed safety materials carefully!
  • Fasten the manual near the garage door after installation.
  • The door WILL NOT CLOSE unless the Protector System ® is connected and properly
  • Periodic checks of the opener are required to ensure safe operation.
  • The model number label is located under the light lens on the left side panel of your
Page 3 of the Chamberlain 3885C user manual — CAUTION
Page 3 · cliquer pour agrandir
Page 3
Chamberlain 3885C — Preparing your garage door diagram (page 3)
Fig. 3 · Preparing your garage door
  • Before you begin:
  • Disable locks.
  • Remove any ropes connected to garage door.
  • Complete the following test to make sure your garage door is balanced and is not sticking or binding: 1. Lift the door about halfway as shown. Release the door. If balanced, it should stay in place, supported entirely by its springs. 2. Raise and lower the door to see if there is any binding or sticking. If your door binds, sticks, or is out of balance, call a trained door systems technician.
  • To prevent possible SERIOUS INJURY or DEATH:
  • ALWAYS call a trained door systems technician if garage door binds, sticks or is out of balance. An unbalanced garage door may not reverse when required.
  • NEVER try to loosen, move or adjust garage door, door springs, cables, pulleys, brackets or their hardware, ALL of which are under EXTREME tension.
  • Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement.

CAUTION

  • To prevent damage to garage door and opener:
  • ALWAYS disable locks BEFORE installing and operating the opener.
  • ONLY operate garage door opener at 120V, 60 Hz to avoid malfunction and damage.
Chamberlain 3885C — CAUTION diagram (page 3)
Fig. 4

During assembly, installation and adjustment of the opener, instructions will call for hand tools as illustrated below.

Adjustable End Wrench Sockets and Wrench 1/2", 5/8", 7/16", 9/16" and 1/4"

Page 4 of the Chamberlain 3885C user manual — Planning
Page 4 · cliquer pour agrandir
Page 4

Planning

Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener.

Chamberlain 3885C — Planning diagram (page 4)
Fig. 5 · Planning

Support bracket & fastening hardware is required. See page 12.

Horizontal and vertical reinforcement is needed for lightweight garage doors (fiberglass, steel, aluminum, door with glass panels, etc.). See page 19 for details.

Safety Reversing Sensor Gap between floor and bottom of door must not exceed 1/4" (6 mm)

Support bracket & fastening hardware is required. See page 12.

Safety Reversing Sensor Gap between floor and bottom of door must not exceed 1/4" (6 mm)

Safety Reversing Sensor Gap between floor and bottom of door must not exceed 1/4" (6 mm).

Page 5 of the Chamberlain 3885C user manual — Carton Inventory
Page 5 · cliquer pour agrandir
Page 5

Carton Inventory

Your garage door opener is packaged in two cartons which contain the motor unit and all parts illustrated below. Accessories will depend on the model

purchased. If anything is missing, carefully check the packing material. Parts may be stuck in the foam. Hardware for installation is also listed below.

Belt Cap Retainer SECURITY✚® Remote Control 3-Button Remote Control Transmitter Visor Clip LO CK Styrofoam LIGHT Motion Detecting Door Control Console (LCD) Belt Motor Unit w/Light Lenses One-Piece Rail 2-Conductor Bell Wire White & White/Red GMOUN TONL Y PCEILIN Door Bracket U Trolley Header Bracket Belt Pulley Bracket Curved Door Arm Section The Protector System® Straight Door (2) Safety Reversing Sensors Safety Labels Arm Section (1 Sending Eye and 1 Receiving Eye) and Safety Sensor with 2-Conductor White & White/Black Literature Bracket (2) Bell Wire attached INSTALLATION HARDWARE STALLATION HARDWARE H H L L C C C N L Sex Bolt 5/16"-18x7/8" (4) Self-Threading Screw 1/4"-14x5/8" (2) ex Screw #8 x 3/8" (2) Screw 6-32x1" (2) ag Screw 5/16"-9x1-5/8" (2) Insulated Staples (30) ag Screw 5/16"-18x1-7/8" (2) Ring Fastener (3) levis Pin 5/16"x2-3/4" (1) Drywall Anchors (2) levis Pin 5/16"x1-1/4" (1) Rope levis Pin 5/16"x1" (1) Handle ut 5/16"-18 (4) Rail Grease ock Washer 5/16" (4) Carriage Bolt 1/4"-20x1/2" (2) crew 6ABx1-1/4" (2) Wing Nut 1/4”-20 (2)
Page 6 of the Chamberlain 3885C user manual — ASSEMBLY STEP 1 Attach the Rail to the Motor Unit
Page 6 · cliquer pour agrandir
Page 6
Chamberlain 3885C — Assembly diagram (page 6)
Fig. 6 · Assembly

ASSEMBLY STEP 1 Attach the Rail to the Motor Unit

To avoid SERIOUS damage to opener, ONLY use bolts/fasteners mounted in top of motor unit.

  • To avoid installation difficulties, do not run the garage door opener until instructed to do so.
  • Remove the bolt and lock nut from the top of the motor unit.
  • Place rail onto the bolt mounted on the motor unit and align the back hole with the hole in the top of the unit.
  • Fasten rail with the washered bolt and lock nut previously removed. Tighten securely. Remember to use only these bolts/fasteners! Any other bolts/fasteners will cause serious damage to the opener.
  • Cut tape from rail, belt and styrofoam.
  • REMOVE STYROFOAM.
  • Position belt over the motor unit sprocket. Motor unit Sprocket
Chamberlain 3885C — ASSEMBLY STEP 1 Attach the Rail to the Motor Unit diagram (page 6)
Fig. 7 · ASSEMBLY STEP 1 Attach the Rail to the Motor Unit
Chamberlain 3885C — ASSEMBLY STEP 1 Attach the Rail to the Motor Unit diagram (page 6)
Fig. 8 · ASSEMBLY STEP 1 Attach the Rail to the Motor Unit
  • By hand, thread the spring trolley nut on the threaded shaft until it is finger tight against the trolley (Figure 1). Do not use any tools.
  • Insert a screwdriver tip into one of the nut ring slots and brace it firmly against the trolley (Figure 2).
  • Place a 7/16" open end wrench on the square end. Rotate about 1/4 turn until the spring releases and snaps the nut ring against the trolley (Figure 3). This extends the spring for optimum belt tension.
Chamberlain 3885C — ASSEMBLY STEP 1 Attach the Rail to the Motor Unit diagram (page 6)
Fig. 9 · ASSEMBLY STEP 1 Attach the Rail to the Motor Unit

1" (2.5 cm) 1-1/4" (3.18 cm) BEFORE AFTER RELEASE

Page 7 of the Chamberlain 3885C user manual — IMPORTANT INSTALLATION INSTRUCTIONS
Page 7 · cliquer pour agrandir
Page 7
Chamberlain 3885C — Step 3 Attach the Belt Cap Retainer diagram (page 7)
Fig. 10 · Step 3 Attach the Belt Cap Retainer
  • To avoid possible SERIOUS INJURY to fingers from moving garage door opener:
  • ALWAYS keep hand clear of sprocket while operating opener.
  • Securely attach sprocket cover BEFORE operating.
  • Position the belt cap retainer over the motor unit sprocket so the two holes in cap align with the two holes in mounting plate. Attach with 8x3/8" hex screws provided.

You have now finished assembling your garage door opener. Please read the following warnings before proceeding to the installation section.

IMPORTANT INSTALLATION INSTRUCTIONS

To reduce the risk of SEVERE INJURY or DEATH:

1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS. 2. Install garage door opener ONLY on properly balanced and lubricated garage door. An improperly balanced door may not reverse when required and could result in SEVERE INJURY or DEATH. 3. ALL repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener. 4. Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement. 5. Install garage door opener 7 feet (2.13 m) or more above floor. 6. Mount emergency release handle 6 feet (1.83 m) above floor. 7. NEVER connect garage door opener to power source until instructed to do so.

  • 8. NEVER wear watches, rings or loose clothing while installing or servicing opener. They could be caught in garage door or opener mechanisms. 9. Install wall-mounted garage door control:
  • within sight of the garage door.
  • out of reach of children at minimum height of 5 feet (1.5 m).
  • away from ALL moving parts of the door. 10. Place entrapment warning label on wall next to garage door control. 11. Place manual release/safety reverse test label in plain view on inside of garage door. 12. Upon completion of installation, test safety reversal system. Door MUST reverse on contact with a 1-1/2" (3.8 cm) high object (or a 2x4 laid flat) on the floor.
Page 8 of the Chamberlain 3885C user manual — OPTIONAL CEILING MOUNT FOR HEADER BRACKET
Page 8 · cliquer pour agrandir
Page 8

INSTALLATION STEP 1 Determine the Header Bracket Location

OPTIONAL CEILING MOUNT FOR HEADER BRACKET

  • To prevent possible SERIOUS INJURY or DEATH:
  • Header bracket MUST be RIGIDLY fastened to structural support on header wall or ceiling, otherwise garage door might not reverse when required. DO NOT install header bracket over drywall.
  • Concrete anchors MUST be used if mounting header bracket or 2x4 into masonry.
  • NEVER try to loosen, move or adjust garage door, springs, cables, pulleys, brackets or their hardware, ALL of which are under EXTREME tension.
  • ALWAYS call a trained door systems technician if garage door binds, sticks or is out of balance. An unbalanced garage door might not reverse when required.

Vertical Centerline of Garage Door

Installation procedures vary according to garage door types. Follow the instructions which apply to your door. 1. Close the door and mark the inside vertical centerline of the garage door. 2. Extend the line onto the header wall above the door. You can fasten the header bracket within 4 feet (1.22 m) of the left or right of the door center only if a torsion spring or center bearing plate is in the way; or you can attach it to the ceiling (see page 9) when clearance is minimal. (It may be mounted on the wall upside down if necessary, to gain approximately 1/2" (1 cm). If you need to install the header bracket on a 2x4 (on wall or ceiling), use lag screws (not provided) to securely fasten the 2x4 to structural supports as shown here and on page 9. 3. Open your door to the highest point of travel as shown. Draw an intersecting horizontal line on the header wall above the high point:

2" (5 cm) Track

Highest Point of Travel

Highest Point of Travel

One-piece door with horizontal track

Sectional door with curved track

  • 2" (5 cm) above the high point for sectional door and one-piece door with track.
  • 8" (20 cm) above the high point for one-piece door without track. This height will provide travel clearance for the top edge of the door. NOTE: If the total number of inches exceeds the height available in your garage, use the maximum height possible, or refer to page 9 for ceiling installation.

Highest Point of Travel

Highest Point of Travel Door

One-piece door without trackjamb hardware
One-piece door without trackpivot hardware
Show 16 more labels / short text on this page
Unfinished Ceiling · Header Wall · Structural Supports · Level (optional) · Header Wall · Track Header Wall · 2" (5 cm) · Door · Door · Header Wall · Header Wall · 8" (20 cm) · 8" (20 cm) · Door · Jamb Hardware · Pivot
Page 9 of the Chamberlain 3885C user manual — HARDWARE SHOWN ACTUAL SIZE
Page 9 · cliquer pour agrandir
Page 9

INSTALLATION STEP 2 Install the Header Bracket

Chamberlain 3885C — INSTALLATION STEP 2 Install the Header Bracket diagram (page 9)
Fig. 11 · INSTALLATION STEP 2 Install the Header Bracket

You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements. Do not install the header bracket over drywall. If installing into masonry, use concrete anchors (not provided).

The nail hole is for positioning only. You must use lag screws to mount the header bracket.

  • WALL HEADER BRACKET INSTALLATION
  • Center the bracket on the vertical centerline with the bottom edge of the bracket on the horizontal line as shown (with the arrow pointing toward the ceiling).
  • Mark the vertical set of bracket holes (do not use the holes designated for ceiling mount). Drill 3/16" pilot holes and fasten the bracket securely to a structural support with the hardware provided.

HARDWARE SHOWN ACTUAL SIZE

Chamberlain 3885C — HARDWARE SHOWN ACTUAL SIZE diagram (page 9)
Fig. 12
  • CEILING HEADER BRACKET INSTALLATION
  • Extend the vertical centerline onto the ceiling as shown.
  • Center the bracket on the vertical mark, no more than 6" (15 cm) from the wall. Make sure the arrow is pointing toward the wall. The bracket can be mounted flush against the ceiling when clearance is minimal.
  • Mark the side holes. Drill 3/16" pilot holes and fasten bracket securely to a structural support with the hardware provided.

The nail hole is for positioning only. You must use lag screws to mount the header bracket.

Lag Screw 5/16"-9x1-5/8"

Page 10 of the Chamberlain 3885C user manual — INSTALLATION STEP 3 Attach the Rail to the Header Bracket
Page 10 · cliquer pour agrandir
Page 10

INSTALLATION STEP 3 Attach the Rail to the Header Bracket

Chamberlain 3885C — INSTALLATION STEP 3 Attach the Rail to the Header Bracket diagram (page 10)
Fig. 13 · INSTALLATION STEP 3 Attach the Rail to the Header Br…
  • Position the opener on the garage floor below the header bracket. Use packing material as a protective base. NOTE: If the door spring is in the way you’ll need help. Have someone hold the opener securely on a temporary support to allow the rail to clear the spring.
  • Position the rail bracket against the header bracket.
  • Align the bracket holes and join with a clevis pin as shown.
  • Insert a ring fastener to secure.
Chamberlain 3885C — INSTALLATION STEP 3 Attach the Rail to the Header Bracket diagram (page 10)
Fig. 14 · INSTALLATION STEP 3 Attach the Rail to the Header Br…
Page 11 of the Chamberlain 3885C user manual — INSTALLATION STEP 4 Position the Opener
Page 11 · cliquer pour agrandir
Page 11

INSTALLATION STEP 4 Position the Opener

CAUTION

To prevent damage to garage door, rest garage door opener rail on 2x4 placed on top section of door.

Follow instructions which apply to your door type as illustrated.

Chamberlain 3885C — INSTALLATION STEP 4 Position the Opener diagram (page 11)
Fig. 15 · INSTALLATION STEP 4 Position the Opener
  • SECTIONAL DOOR OR ONE-PIECE DOOR WITH TRACK A 2x4 laid flat is convenient for setting an ideal door-to-rail distance.
  • Remove foam packaging.
  • Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough.
  • Open the door all the way and place a 2x4 laid flat on the top section beneath the rail.
  • If the top section or panel hits the trolley when you raise the door, pull down on the trolley release arm to disconnect inner and outer sections. Slide the outer trolley toward the motor unit. The trolley can remain disconnected until Installation Step 12 is completed.

Door 2x4 is used to determine the correct mounting height from ceiling.

Chamberlain 3885C — INSTALLATION STEP 4 Position the Opener diagram (page 11)
Fig. 16 · INSTALLATION STEP 4 Position the Opener
Chamberlain 3885C — INSTALLATION STEP 4 Position the Opener diagram (page 11)
Fig. 17 · INSTALLATION STEP 4 Position the Opener
Chamberlain 3885C — INSTALLATION STEP 4 Position the Opener diagram (page 11)
Fig. 18 · INSTALLATION STEP 4 Position the Opener
  • ONE-PIECE DOOR WITHOUT TRACK A 2x4 on its side is convenient for setting an ideal door-to-rail distance.
  • Remove foam packaging.
  • Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough.
  • Open the door all the way and place a 2x4 on its side on the top section of the door beneath the rail.
  • The top of the door should be level with the top of the motor unit. Do not position the opener more than 4" (10 cm) above this point.

Top of Door 2x4 is used to determine the correct mounting height from ceiling.

Page 12 of the Chamberlain 3885C user manual — FINISHED CEILING
Page 12 · cliquer pour agrandir
Page 12
Chamberlain 3885C — Step 5 Hang the Opener diagram (page 12)
Fig. 19 · Step 5 Hang the Opener

INSTALLATION STEP 5 Hang the Opener

To avoid possible SERIOUS INJURY from a falling garage door opener, fasten it SECURELY to structural supports of the garage. Concrete anchors MUST be used if installing any brackets into masonry.

Three representative installations are shown. Yours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On finished ceilings (Figure 2 and Figure 3), attach a sturdy metal bracket to structural supports before installing the opener. This bracket and fastening hardware are not provided. 1. Measure the distance from each side of the motor unit to the structural support. 2. Cut both pieces of the hanging bracket to required lengths. 3. Drill 3/16" pilot holes in the structural supports. 4. Attach one end of each bracket to a support with 5/16"-18x1-7/8" lag screws. 5. Fasten the opener to the hanging brackets with 5/16"-18x7/8" hex bolts, lock washers and nuts. 6. Check to make sure the rail is centered over the door (or in line with the header bracket if the bracket is not centered above the door). 7. Remove the 2x4. Operate the door manually. If the door hits the rail, raise the header bracket. 8. Grease the top and underside of the rail surface where the trolley slides with rail grease. NOTE: DO NOT connect power to opener at this time.

Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18

FINISHED CEILING

(Not Provided) Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18

Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18

HARDWARE SHOWN ACTUAL SIZE

Hex Bolt 5/16"-18x7/8" Nut 5/16"-18 Lock Washer 5/16"

FINISHED CEILING

(Not Provided) Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18

Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18

Show 8 more labels / short text on this page
Structural Supports · Measure Distance · Lag Screws 5/16"-18x1-7/8" · Hidden Support · Bracket (Not Provided) · Lag Screws 5/16"-18x1-7/8" · Lag Screw 5/16"-18x1-7/8" · Lag Screws 5/16"-18x1-7/8"
Page 13 of the Chamberlain 3885C user manual — W 2 R 1
Page 13 · cliquer pour agrandir
Page 13
  • INSTALLATION STEP 6 Install the Control Console Locate control console within sight of door, at a minimum height of 5' (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided. For pre-wired installations (as in new home construction), it may be mounted to a single gang box (Figure 1). CAUTION: Continuous exposure of the control console to temperatures below -22° F (-30° C) may damage the LCD screen. NOTE: The functional temperature range of the control console is between -20° C (-4° F) and 50° C (122° F). Scroll speed of display is slower at lower temperatures although the control console remains fully functional. SPECIAL NOTE: Only one 398LM can be connected to each garage door opener. If additional wall controls are desired to operate the same garage door opener, it is recommended to use model 378LM wireless wall control as the secondary control console. 1. Strip 7/16" (11 mm) of insulation from one end of bell wire and connect to the two screw terminals on back of control console by color: white wire to the white (2) and white/red wire to the red (1) (Figure 2). 2. Remove push bar cover by gently prying at the lower/middle portion of the cover with a small flat-head screwdriver. Fasten with 6AB x 1-1/4" self-tapping screws (drywall installation) or 6-32 x 1" machine screws (into gang box) as follows:
  • Install bottom screw, allowing 1/8" (3 mm) to protrude above wall surface.
  • Position bottom of control console on screw head and slide down to secure. Adjust screw for snug fit.
  • Drill and install top screw with care to avoid cracking plastic housing. Do NOT overtighten.
  • Replace cover by inserting top tabs first and then snap cover in place. 3. (For standard installations ONLY) Run bell wire up wall and across ceiling to motor unit. Use insulated staples to secure wire in several places. Do NOT pierce wire with a staple, creating a short or open circuit. 4. Strip 7/16" (11 mm) of insulation from end of bell wire. Connect bell wire to the quick-connect terminals on the motor unit: white to white and white/red to red (Figure 3). NOTE: If you have any trouble with the operation of the buttons, loosen the top mounting screw. NOTE: DO NOT connect the power and operate the opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned. See Safety Reversing Sensor Instructions beginning on page 16.
  • To prevent possible SERIOUS INJURY or DEATH from electrocution:
  • Be sure power is not connected BEFORE installing door control.
  • Connect ONLY to 24 VOLT low voltage wires. To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
  • Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m) and away from ALL moving parts of door.
  • NEVER permit children to operate or play with door control push buttons or remote control transmitters.
  • Activate door ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to door travel.
  • ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.

HARDWARE SHOWN ACTUAL SIZE

Insulated Staples Screw 6ABx1-1/4" (std installation)

STANDARD WALL MOUNT

PRE-WIRED INSTALLATION

To Replace Insert Top Tabs First

24 Volt Bell Wire

To Replace Insert Top Tabs First

ON OFF

LIGHT Push Bar Cover Detector Switch

LOCK

LOCK

ON OFF

LIGHT

Door Control Terminal Screws

W 2 R 1

(BACK VIEW)

To release wire, push in tab with screwdriver tip Door Control Connections

Strip wire 7/16" (11 mm)

Show 10 more labels / short text on this page
Screw 6-32x1" (pre-wired) · Drywall Anchors · Push Bar Cover · Detector · Switch · 2-Conductor Bell Wire · Top Mounting Hole · Bottom Mounting Hole · Red Grey White · 7/16" (11 mm)
Page 14 of the Chamberlain 3885C user manual — INSTALLATION STEP 8 Attach the Emergency Release Rope and Handle
Page 14 · cliquer pour agrandir
Page 14
Chamberlain 3885C — Step 7 Install the Light diagram (page 14)
Fig. 20 · Step 7 Install the Light

INSTALLATION STEP 7 Install the Light

  • To prevent possible OVERHEATING of the endpanel or light socket:
  • DO NOT use short neck or specialty light bulbs.
  • DO NOT use halogen bulbs. Use ONLY incandescent. To prevent damage to the opener:
  • DO NOT use bulbs larger than 100W.
  • ONLY use A19 size bulbs.
  • Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens.
  • Install a 100 watt maximum light bulb in each socket. Light bulb size should be A19, standard neck only. The lights will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the lights will turn OFF.
  • Reverse the procedure to close the lens.
  • Use A19, standard neck garage door opener bulbs for replacement. NOTE: Use only standard light bulbs. The use of short neck or speciality light bulbs may overheat the endpanel or light socket.
Chamberlain 3885C — INSTALLATION STEP 7 Install the Light diagram (page 14)
Fig. 21 · INSTALLATION STEP 7 Install the Light
Chamberlain 3885C — INSTALLATION STEP 7 Install the Light diagram (page 14)
Fig. 22 · INSTALLATION STEP 7 Install the Light

INSTALLATION STEP 8 Attach the Emergency Release Rope and Handle

  • To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
  • If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
  • NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
  • NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
  • Thread one end of the rope through the hole in the top of the red handle so “NOTICE” reads right side up as shown. Secure with an overhand knot at least 1" (2.5 cm) from the end of the rope to prevent slipping.
  • Thread the other end of the rope through the hole in the release arm of the outer trolley.
  • Adjust rope length so the handle is 6 feet (1.83 m) above the floor. Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement. Secure with an overhand knot. NOTE: If it is necessary to cut the rope, heat seal the cut end with a match or lighter to prevent unraveling.
Chamberlain 3885C — INSTALLATION STEP 8 Attach the Emergency Release Rope and Handle diagram (page 14)
Fig. 23 · INSTALLATION STEP 8 Attach the Emergency Release Rop…
Page 15 of the Chamberlain 3885C user manual — PERMANENT WIRING CONNECTION
Page 15 · cliquer pour agrandir
Page 15

INSTALLATION STEP 9 Electrical Requirements

  • To prevent possible SERIOUS INJURY or DEATH from electrocution or fire:
  • Be sure power is not connected to the opener and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection.
  • Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes.
  • NEVER use an extension cord, 2-wire adapter or change plug in ANY way to make it fit outlet. Be sure the opener is grounded.

To avoid installation difficulties, do not run the opener at this time. To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet. If the plug doesn’t fit into the outlet you have, contact a qualified electrician to install the proper outlet.

PERMANENT WIRING CONNECTION

RIGHT WRONG

  • If permanent wiring is required by your local code, refer to the following procedure. To make a permanent connection through the 7/8" hole in the top of the motor unit:
  • Remove the motor unit cover screws and set the cover aside.
  • Remove the attached 3-prong cord.
  • Connect the black (line) wire to the screw on the brass terminal; the white (neutral) wire to the screw on the silver terminal; and the ground wire to the green ground screw. The opener must be grounded.
  • Reinstall the cover. To avoid installation difficulties, do not run the opener at this time.
Show 6 more labels / short text on this page
Ground Tab · Green Ground Screw · Black Wire · Ground Wire · White Wire · Black Wire
Page 16 of the Chamberlain 3885C user manual — Facing the door from inside the garage
Page 16 · cliquer pour agrandir
Page 16

INSTALLATION STEP 10 Install The Protector System ®

  • Be sure power is not connected to the garage door opener BEFORE installing the safety reversing sensor. To prevent SERIOUS INJURY or DEATH from a closing garage door:
  • Correctly connect and align the safety reversing sensor. This required safety device MUST NOT be disabled.
  • Install the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage floor.

The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction.

IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR When properly connected and aligned, the sensor will detect an obstacle in the path of its electronic beam. The sending eye (with an amber indicator light) transmits an invisible light beam to the receiving eye (with a green indicator light). If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to full open position, and the opener lights will flash 10 times. The units must be installed inside the garage so that the sending and receiving eyes face each other across the door, no more than 6" (15 cm) above the floor. Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens. The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware.

If it is necessary to mount the units on the wall, the brackets must be securely fastened to a solid surface such as the wall framing. Extension brackets (see accessories) are available if needed. If installing in masonry construction, add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary. The invisible light beam path must be unobstructed. No part of the garage door (or door tracks, springs, hinges, rollers or other hardware) may interrupt the beam while the door is closing.

Safety Reversing Sensor 6" (15 cm) max. above floor Safety Reversing Sensor 6" (15 cm) max. above floor

Invisible Light Beam Protection Area

Facing the door from inside the garage

Page 17 of the Chamberlain 3885C user manual — FLOOR MOUNT (RIGHT SIDE)
Page 17 · cliquer pour agrandir
Page 17

INSTALLING THE BRACKETS Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the floor. They may be installed in one of three ways, as follows.

DOOR TRACK MOUNT (RIGHT SIDE)

Garage door track installation (preferred): • Slip the curved arms over the rounded edge of each door track, with the curved arms facing the door. Snap into place against the side of the track. It should lie flush, with the lip hugging the back edge of the track, as shown in Figure 1. If your door track will not support the bracket securely, wall installation is recommended.

  • Wall installation (Figure 2 & 3):
  • Place the bracket against the wall with curved arms facing the door. Be sure there is enough clearance for the sensor beam to be unobstructed.
  • If additional depth is needed, an extension bracket (see accessories) or wood blocks can be used.
  • Use bracket mounting holes as a template to locate and drill (2) 3/16" diameter pilot holes on the wall at each side of the door, no higher than 6" (15 cm) above the floor.
  • Attach brackets to wall with lag screws (Not provided).
  • If using extension brackets or wood blocks, adjust right and left assemblies to the same distance out from the mounting surface. Make sure all door hardware obstructions are cleared.

WALL MOUNT (RIGHT SIDE)

Fasten Wood Block to Wall with Lag Screws (Not Provided)

Indicator Light Sensor Bracket

Lag Screws (Not Provided)

WALL MOUNT (RIGHT SIDE)

Extension Bracket (See Accessories)

  • Floor installation (Figure 4):
  • Use wood blocks or extension brackets (see Accessories) to elevate sensor brackets so the lenses will be no higher than 6" (15 cm) above the floor.
  • Carefully measure and place right and left assemblies at the same distance out from the wall. Be sure all door hardware obstructions are cleared.
  • Fasten to the floor with concrete anchors as shown.

(Provided with Extension Bracket)

(Provided with Extension Bracket)

FLOOR MOUNT (RIGHT SIDE)

HARDWARE SHOWN ACTUAL SIZE

Attach with Concrete Anchors (Not Provided)

Wing Nut 1/4"-20 Staples Carriage Bolt 1/4"-20x1/2"

Show 15 more labels / short text on this page
Door Track · Lip · Indicator Light · Sensor Bracket · Lens · Inside Garage Wall · Lens · Inside Garage Wall · Sensor Bracket · Indicator Light · Lens · Inside Garage Wall · Lens · Indicator Light · Sensor Bracket
Page 18 of the Chamberlain 3885C user manual — Step 10 Install The Protector System
Page 18 · cliquer pour agrandir
Page 18
  • Figure 5 MOUNTING AND WIRING THE SAFETY REVERSING SENSORS
  • Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5).
  • Finger tighten the wing nuts.
  • Run the wires from both sensors to the opener. Use insulated staples to secure wire to wall and ceiling.
  • Strip 7/16" (11 mm) of insulation from each set of wires. Separate white and white/black wires sufficiently to connect to the opener quick-connect terminals. Twist like colored wires together. Insert wires into quick-connect holes: white to white and white/black to grey (Figure 6).
Chamberlain 3885C — Step 10 Install The Protector System diagram (page 18)
Fig. 24 · Step 10 Install The Protector System

TROUBLESHOOTING THE SAFETY REVERSING SENSORS 1. If the sending eye indicator light does not glow steadily after installation, check for:

  • Electric power to the opener.
  • A short in the white or white/black wires. These can occur at staples, or at opener connections.
  • Incorrect wiring between sensors and opener.
  • A broken wire. 2. If the sending eye indicator light glows steadily but the receiving eye indicator light doesn’t:
  • ALIGNING THE SAFETY REVERSING SENSORS
  • Plug in the opener. The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct. The sending eye amber indicator light will glow regardless of alignment or obstruction. If the green indicator light in the receiving eye is off, dim, or flickering (and the invisible light beam path is not obstructed), alignment is required.
  • Loosen the sending eye wing nut and readjust, aiming directly at the receiving eye. Lock in place.
  • Loosen the receiving eye wing nut and adjust sensor until it receives the sender’s beam. When the green indicator light glows steadily , tighten the wing nut.
  • Check alignment.
  • Check for an open wire to the receiving eye. 3. If the receiving eye indicator light is dim, realign either sensor. NOTE: When the invisible beam path is obstructed or misaligned while the door is closing, the door will reverse. If the door is already open, it will not close. The opener lights will blink 10 times. See page 16.
Chamberlain 3885C — Step 10 Install The Protector System diagram (page 18)
Fig. 25 · Step 10 Install The Protector System
Page 19 of the Chamberlain 3885C user manual — UP
Page 19 · cliquer pour agrandir
Page 19

CAUTION INSTALLATION STEP 11 Fasten the Door Bracket

Fiberglass, aluminum or lightweight steel garage doors will require reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit.

Follow instructions which apply to your door type as illustrated below or on the following page. A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports. A vertical reinforcement brace should cover the height of the top panel. Figure 1 shows one piece of angle iron as the horizontal brace. For the vertical brace, 2 pieces of angle iron are used to create a U-shaped support. The best solution is to check with your garage door manufacturer for an opener installation door reinforcement kit. NOTE: Many door reinforcement kits provide for direct attachment of the clevis pin and door arm. In this case you will not need the door bracket; proceed to Step 12.

HORIZONTAL AND VERTICAL REINFORCEMENT IS NEEDED FOR LIGHTWEIGHT GARAGE DOORS (FIBERGLASS, ALUMINUM, STEEL, DOORS WITH GLASS PANEL, ETC.). (NOT PROVIDED)

Vertical Centerline of Garage Door

SECTIONAL DOORS 1. Center the door bracket on the previously marked vertical centerline used for the header bracket installation. Note correct UP placement, as stamped inside the bracket. 2. Position the top edge of the bracket 2"-4" (5-10 cm) below the top edge of the door, OR directly below any structural support across the top of the door. 3. Mark, drill holes and install as follows, depending on your door’s construction:

Vertical Reinforcement (Not Provided)

Vertical Centerline of Garage Door

Vertical Centerline of Garage Door

  • Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket:
  • Drill 3/16" fastening holes. Secure the door bracket using the two 1/4"-14x5/8" self-threading screws (Figure 2A).
  • Alternately, use two 5/16" bolts, lock washers and nuts (not provided) (Figure 2B).

UP

UP

Metal, insulated or light weight factory reinforced doors: • Drill 3/16" fastening holes. Secure the door bracket using the self-threading screws (Figure 3).

Inside Edge of Door or Reinforcement Board

Wood Doors: • Use top and bottom or side to side door bracket holes. Drill 5/16" holes through the door and secure bracket with 5/16"x2" carriage bolts, lock washers and nuts (not provided) (Figure 4). NOTE: The 1/4"-14x5/8" self-threading screws are not intended for use on wood doors.

UP

Vertical Centerline of Garage Door

Vertical Centerline of Garage Door

UP

HARDWARE SHOWN ACTUAL SIZE

Show 13 more labels / short text on this page
Header Bracket · Door Bracket Location · Vertical Reinforcement · Bolt 5/16"-18x2" · Door Bracket · Lock Washer 5/16" · Door Bracket · Nut 5/16"-18 · Self-Threading Screw 1/4"-14x5/8" · (Not Provided) · Bolt 5/16"x2" · Self-Threading Screw 1/4"-14x5/8" · Self-Threading Screw 1/4"-14x5/8"
Page 20 of the Chamberlain 3885C user manual — HARDWARE SHOWN
Page 20 · cliquer pour agrandir
Page 20
  • ONE-PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page. They apply to one-piece doors also.
  • Center the door bracket on the top of the door, in line with the header bracket as shown. Mark either the left and right, or the top and bottom holes.
  • Metal Doors: Drill 3/16" pilot holes and fasten the bracket with the 1/4"-14x5/8" self-threading screws provided.
  • Wood Doors: Drill 5/16" holes and use 5/16"x2" carriage bolts, lock washers and nuts (not provided) or 5/16"x1-1/2" lag screws (not provided) depending on your installation needs.

HARDWARE SHOWN

ACTUAL SIZE

Chamberlain 3885C — HARDWARE SHOWN diagram (page 20)
Fig. 26

HORIZONTAL AND VERTICAL REINFORCEMENT IS NEEDED FOR LIGHTWEIGHT GARAGE DOORS (FIBERGLASS, ALUMINUM, STEEL, DOORS WITH GLASS PANEL, ETC.). (NOT PROVIDED)

For a door with no exposed framing, or for the optional installation, use lag screws 5/16"x1-1/2" (Not Provided) to fasten door bracket.

Self-Threading Screw 1/4"-14x5/8"

Page 21 of the Chamberlain 3885C user manual — HARDWARE SHOWN ACTUAL SIZE
Page 21 · cliquer pour agrandir
Page 21

INSTALLATION STEP 12 Connect the Door Arm to the Trolley

Follow instructions which apply to your door type as illustrated below and on the following page.

  • SECTIONAL DOORS ONLY
  • Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley. Slide the outer trolley back (away from the door) about 2" (5 cm) as shown in Figures 1, 2 and 3.
  • Figure 1: – Fasten straight door arm section to outer trolley

with the 5/16"x1" clevis pin. Secure the connection with a ring fastener. – Fasten curved section to the door bracket in the

same way, using the 5/16"x1-1/4" clevis pin. • Figure 2: – Bring arm sections together. Find two pairs of

holes that line up and join sections. Select holes as far apart as possible to increase door arm rigidity. • Figure 3, Hole alignment alternative: – If holes in curved arm are above holes in straight

arm, disconnect straight arm. Cut about 6" (15 cm) from the solid end. Reconnect to trolley with cut end down as shown. – Bring arm sections together. – Find two pairs of holes that line up and join with

bolts, lock washers and nuts. • Pull the emergency release handle toward the opener at a 45° angle so that the trolley release arm is horizontal. Proceed to Adjustment Step 1, page 23. Trolley will re-engage automatically when opener is operated.

HARDWARE SHOWN ACTUAL SIZE

Lock Washer 5/16" Nut 5/16"-18 Ring Fastener

Hex Bolt 5/16"-18x7/8" Clevis Pin 5/16"x1" (Trolley) Clevis Pin 5/16"x1-1/4" (Door Bracket)

Show 17 more labels / short text on this page
Inner Trolley · Outer Trolley · Clevis Pin 5/16"x1" · Ring Fastener · Door Bracket · Straight Door Arm · Curved Door Arm · Clevis Pin 5/16"x1-1/4" · Lock Washers 5/16" · Nuts 5/16"-18 · Emergency Release Handle · Bolts 5/16"-18x7/8" · Door Bracket · Lock Washers 5/16" · Nuts 5/16"-18 · Bolts 5/16"-18x7/8" · Cut This End
Page 22 of the Chamberlain 3885C user manual — Step 12 Connect the Door Arm to the Trolley
Page 22 · cliquer pour agrandir
Page 22
  • ALL ONE-PIECE DOORS 1. Assemble the door arm, Figure 4:
  • Fasten the straight and curved door arm sections together to the longest possible length (with a 2 or 3 hole overlap).
  • With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin.
  • Secure with a ring fastener. 2. Adjustment procedures, Figure 5:
  • On one-piece doors, before connecting the door arm to the trolley, the travel limits must be adjusted. Limit adjustment screws are located on the left side panel as shown on page 23. Follow adjustment procedures below.
  • Open door adjustment: decrease UP travel limit - Turn the UP limit adjustment screw

Nuts 5/16"-18 Lock Washers 5/16"

- Press the Door Control push button. The trolley

will travel to the fully closed position. - Manually close the door and lift the door arm to

  • the trolley. The arm should touch the trolley just ahead of the door arm connector hole. Refer to the fully closed trolley/door arm positions in the illustration. If the arm is behind the connector hole, adjust the limit further. One full turn equals 3" (7.5 cm) of trolley travel. 3. Connect the door arm to the trolley:
  • Close the door and join the curved arm to the connector hole in the trolley with the remaining clevis pin. It may be necessary to lift the door slightly to make the connection.
  • Secure with a ring fastener.
  • Run the opener through a complete travel cycle. If the door has a slight “backward” slant in full open position as shown in the illustration, decrease the UP limit until the door is parallel to the floor. NOTE: When setting the up limit on the following page, the door should not have a “backward” slant when fully open as illustrated below. A slight backward slant will cause unnecessary bucking and/or jerking operation as the door is being opened or closed from the fully open position.

counter-clockwise 4 turns. - Press the Door Control push button. The trolley

will travel to the fully open position. - Manually raise the door to the open position

(parallel to the floor), and lift the door arm to the trolley. The arm should touch the trolley just in back of the door arm connector hole. Refer to the fully open trolley/door arm positions in the illustration. If the arm does not extend far enough, adjust the limit further. One full turn equals 3" (7.5 cm) of trolley travel. • Closed door adjustment: decrease DOWN travel limit - Turn the DOWN limit adjustment screw

clockwise 4 complete turns.

Inner Trolley Figure 5

Door Arm Connector Hole

Door Arm Correct Angle

Door with Backward Slant (Incorrect)

Show 13 more labels / short text on this page
Door Bracket · Ring Fastener · Clevis Pin 5/16"x1-1/4" · Straight Arm · Bolts 5/16"-18x7/8 · Curved Door Arm · Outer Trolley · Door Arm · Emergency Release Handle · Closed Door · Inner Trolley · Outer Trolley · Open Door
Page 23 of the Chamberlain 3885C user manual — ADJUSTMENT LABEL
Page 23 · cliquer pour agrandir
Page 23

ADJUSTMENT STEP 1 Adjust the Travel Limits

  • Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
  • Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
  • If one control (force or travel limits) is adjusted, the other control may also need adjustment.
  • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid flat) on floor.
  • Limit adjustment settings regulate the points at which the door will stop when moving up or down. To operate the opener, press the Door Control push bar. Run the opener through a complete travel cycle.
  • Does the door open and close completely?
  • Does the door stay closed and not reverse unintentionally when fully closed? If your door passes both of these tests, no limit adjustments are necessary unless the reversing test fails (Adjustment Step 3, page 25). Adjustment procedures are outlined below. Read the procedures carefully before proceeding to Adjustment Step 2. Use a screwdriver to make limit adjustments. Run the opener through a complete travel cycle after each adjustment. NOTE: Repeated operation of the opener during adjustment procedures may cause the motor to overheat and shut off. Simply wait 15 minutes and try again. NOTE: If anything interferes with the door’s upward travel, it will stop. If anything interferes with the door’s downward travel (including binding or unbalanced doors), it will reverse.

CAUTION

To prevent damage to vehicles, be sure fully open door provides adequate clearance.

HOW AND WHEN TO ADJUST THE LIMITS

  • If the door does not open completely but opens at least 5 feet (1.5 m): Increase up travel. Turn the UP limit adjustment screw clockwise. One turn equals 3" (7.5 cm) of travel. NOTE: To prevent the trolley from hitting the cover protection bolt, keep a minimum distance of 2-4" (5 cm - 10 cm) between the trolley and the bolt.
  • If door does not open at least 5 feet (1.5 m): Adjust the UP (open) force as explained in Adjustment Step 2.

ADJUSTMENT LABEL

  • If the door does not close completely: Increase down travel. Turn the down limit adjustment screw counterclockwise. One turn equals 3" (7.5 cm) of travel. If door still won't close completely and the trolley bumps into the pulley bracket (page 4), try lengthening the door arm (page 21) and decreasing the down limit.
  • If the door reverses when closing and there is no visible interference to travel cycle: If the opener lights are flashing, the Safety Reversing Sensors are either not installed, misaligned, or obstructed. See Troubleshooting, page 18. Test the door for binding: Pull the emergency release handle. Manually open and close the door. If the door is binding or unbalanced, call for a trained door systems technician. If the door is balanced and not binding, adjust the DOWN (close) force. See Adjustment Step 2.
  • If the opener reverses in fully closed position: Decrease down travel. Turn the down limit adjustment screw clockwise. One turn equals 3" (7.5 cm) of travel.
Show 4 more labels / short text on this page
Cover Protection Bolt · 2-4" (5-10 cm) · Left Side Panel · Limit Adjustment Screws
Page 24 of the Chamberlain 3885C user manual — KG KG
Page 24 · cliquer pour agrandir
Page 24

ADJUSTMENT STEP 2 Adjust the Force

  • Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
  • Too much force on garage door will interfere with proper operation of safety reversal system.
  • NEVER increase force beyond minimum amount required to close garage door.
  • NEVER use force adjustments to compensate for a binding or sticking garage door.
  • If one control (force or travel limits) is adjusted, the other control may also need adjustment.
  • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid flat) on floor.

Force adjustment controls are located on the back panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door. If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction. Weather conditions can affect the door movement, so occasional adjustment may be needed. The maximum force adjustment range is about 3/4 of a complete turn. Do not force controls beyond that point. Turn force adjustment controls with a screwdriver. NOTE: If anything interferes with the door’s upward travel, it will stop. If anything interferes with the door’s downward travel (including binding or unbalanced doors), it will reverse.

  • HOW AND WHEN TO ADJUST THE FORCES 1. Test the DOWN (close) force
  • Grasp the door bottom when the door is about halfway through DOWN (close) travel. The door should reverse. Reversal halfway through down travel does not guarantee reversal on a 1-1/2" (3.8 cm) obstruction. See Adjustment Step 3, page 25. If the door is hard to hold or doesn’t reverse, DECREASE the DOWN (close) force by turning the control counterclockwise. Make small adjustments until the door reverses normally. After each adjustment, run the opener through a complete cycle.
  • If the door reverses during the down (close) cycle and the opener lights aren’t flashing, INCREASE DOWN (close) force by turning the control clockwise. Make small adjustments until the door completes a close cycle. After each adjustment, run the opener through a complete travel cycle. Do not increase the force beyond the minimum amount required to close the door. 2. Test the UP (open) force
  • Grasp the door bottom when the door is about halfway through UP (open) travel. The door should stop. If the door is hard to hold or doesn’t stop, DECREASE UP (open) force by turning the control counterclockwise. Make small adjustments until the door stops easily and opens fully. After each adjustment, run the opener through a complete travel cycle.
  • If the door doesn’t open at least 5 feet (1.5 m), INCREASE UP (open) force by turning the control clockwise. Make small adjustments until door opens completely. Readjust the UP limit if necessary. After each adjustment, run the opener through a complete travel cycle.

KG KG

FORCE ADJUSTMENT LABEL

KG KG

Open Force Close Force

Force Adjustment Controls · Right Panel · Antenna

Page 25 of the Chamberlain 3885C user manual — ADJUSTMENT STEP 4 Test The Protector System ®
Page 25 · cliquer pour agrandir
Page 25

ADJUSTMENT STEP 3 Test the Safety Reversal System

  • Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
  • Safety reversal system MUST be tested every month.
  • If one control (force or travel limits) is adjusted, the other control may also need adjustment.
  • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid flat) on the floor.
  • TEST
  • With the door fully open, place a 1-1/2" (3.8 cm) board (or a 2x4 laid flat) on the floor, centered under the garage door.
  • Operate the door in the down direction. The door must reverse on striking the obstruction.
  • ADJUST
  • If the door stops on the obstruction, it is not traveling far enough in the down direction. Increase the DOWN limit by turning the DOWN limit adjustment screw counterclockwise 1/4 turn. NOTE: On a sectional door, make sure limit adjustments do not force the door arm beyond a straight up and down position. See the illustration on page 21.
  • Repeat the test.
  • When the door reverses on the 1-1/2" (3.8 cm) board, remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment.
  • If the unit continues to fail the Safety Reverse Test, call for a trained door systems technician.
  • IMPORTANT SAFETY CHECK: Test the Safety Reverse System after:
  • Each adjustment of door arm length, limits, or force controls.
  • Any repair to or adjustment of the garage door (including springs and hardware).
  • Any repair to or buckling of the garage floor.
  • Any repair to or adjustment of the opener.

1-1/2" (3.8 cm) board (or a 2x4 laid flat)

ADJUSTMENT STEP 4 Test The Protector System ®

Without a properly installed safety reversing sensor, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.

  • Press the remote control push button to open the door.
  • Place the opener carton in the path of the door.
  • Press the remote control push button to close the door. The door will not move more than an inch (2.5 cm), and the opener lights will flash. The garage door opener will not close from a remote if the indicator light in either sensor is off (alerting you to the fact that the sensor is misaligned or obstructed). If the opener closes the door when the safety reversing sensor is obstructed (and the sensors are no more than 6" (15 cm) above the floor), call for a trained door systems technician.

Safety Reversing Sensor Safety Reversing Sensor

Page 26 of the Chamberlain 3885C user manual — Using Your Garage Door Opener
Page 26 · cliquer pour agrandir
Page 26

OPERATION

IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of SEVERE INJURY or DEATH:

1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS. 2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls. 3. ONLY activate garage door when it can be seen clearly, it is properly adjusted and there are no obstructions to door travel. 4. ALWAYS keep garage door in sight until completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY OPEN DOOR. 6. If possible, use emergency release handle to disengage trolley ONLY when garage door is closed. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. 7. NEVER use emergency release handle unless garage doorway is clear of persons and obstructions. 8. NEVER use handle to pull garage door open or closed. If rope knot becomes untied, you could fall.

9. If one control (force or travel limits) is adjusted, the other control may also need adjustment. 10. After ANY adjustments are made, the safety reversal system MUST be tested. 11. Safety reversal system MUST be tested every month. Garage door MUST reverse on contact with 1-1/2" high (3.8 cm) high object (or a 2x4 laid flat) on the floor. 12. ALWAYS keep garage door properly balanced (see page 3). An improperly balanced door may not reverse when required and could result in SEVERE INJURY or DEATH. 13. ALL repairs to cables, spring assemblies and other hardware, ALL of which are under extreme tension, MUST be made by a trained door systems technician. 14. ALWAYS disconnect electric power to garage door opener BEFORE making ANY repairs or removing covers.

15. SAVE THESE INSTRUCTIONS.

Using Your Garage Door Opener

6. If obstructed while opening, the door will stop. 7. If fully open, the door will not close when the beam is broken. The sensor has no effect in the opening cycle. If the sensor is not installed, or is misaligned, the door won’t close from a hand-held remote. However, you can close the door with the Door Control, the Outside Keylock, or Keyless Entry, if you activate them until down travel is complete. If you release them too soon, the door will reverse. The opener lights will turn on under the following conditions: when the opener is initially plugged in; when power is restored after interruption; when the opener is activated. They will turn off automatically after 4-1/2 minutes or provide constant light when the Light feature on the Motion Detecting Control Console is activated. Bulb size is A19. Bulb power is 100 watts maximum. Security✚® light feature: Lights will also turn on when someone walks through the open garage door. With a Motion Detecting Control Console, this feature may be turned off as follows: With the opener lights off, press and hold the light button for 10 seconds, until the light goes on, then off again. To restore this feature, start with the opener lights on, then press and hold the light button for 10 seconds until the light goes off, then on again.

Your Security✚® opener and hand-held remote control have been factory-set to a matching code which changes with each use, randomly accessing over 100 billion new codes. Your opener will operate with up to eight Security✚® remote controls and one Security✚® Keyless Entry System. If you purchase a new remote, or if you wish to deactivate any remote, follow the instructions in the Programming section.

  • Activate your opener with any of the following:
  • The hand-held Remote Control: Hold the large push button down until the door starts to move.
  • The wall-mounted Door Control: Hold the push button or bar down until the door starts to move.
  • The Keyless Entry (See Accessories): If provided with your garage door opener, it must be programmed before use. See Programming.

When the opener is activated (with the safety reversing sensor correctly installed and aligned) 1. If open, the door will close. If closed, it will open. 2. If closing, the door will reverse. 3. If opening, the door will stop. 4. If the door has been stopped in a partially open position, it will close. 5. If obstructed while closing, the door will reverse. If the obstruction interrupts the sensor beam, the opener lights will blink for five seconds.

Page 27 of the Chamberlain 3885C user manual — LOCK
Page 27 · cliquer pour agrandir
Page 27

Using the Wall-Mounted Control Console

(PROG) Learn Feature The control console is equipped with a Prog button to assist in learning remote controls to the unit. Press the Prog button once to initiate LEARN mode and the display will show ‘Learn Remote Control - Press Learn Button Again to Confirm’. Press the Prog button a second time and the display will show ‘Learn Mode - Press Remote Control Button to Learn Remote.’ Press the button of the remote control to be learned and the worklight will blink to confirm the remote control has been learned.

THE LCD MOTION DETECTING CONTROL CONSOLE Press the push bar to open or close the door. Press again to reverse the door during the closing cycle or to stop the door while it's opening. This door control contains a motion sensing detector that will automatically turn on the light when it detects a person entering the garage.

LIGHT LOCK

H M

Hour & Minute Feature

Press or hold either of these side buttons to increment the hour or minute displayed on the LCD display.

Light feature

LIGHT

Press the Light button to turn the opener light on or off. It will not control the opener lights when the door is in motion. If you turn it on and then activate the opener, the light will remain on for 4-1/2 minutes. Press again to turn it off sooner. The 4-1/2 minute interval can be changed to 1-1/2, 2-1/2, or 3-1/2 minutes as follows: Press and hold the Lock button until the light blinks (about 10 seconds). A single blink indicates that the timer is reset to 1-1/2 minutes. Repeat the procedure and the light will blink twice, resetting the timer to 2-1/2 minutes. Repeat again for a 3-1/2 minute interval, etc., up to a maximum of four blinks and 4-1/2 minutes. When using the opener lights as working lights, we recommend that you first disable the motion sensor. See Automatic Light Feature, below.

(LANG) Language Feature Press this side button to toggle between the three languages - English, French and Spanish.

Degrees F/C Feature

Press this side button to toggle the temperature units between Fahrenheit and Celsius.

Display Contrast Adjustment Press and hold the light button then push the hour button to increase the contrast or the minute button to decrease the contrast.

Lock feature

Additional feature when used with the 3-Button hand-held remote To control the opener lights: In addition to operating the door, you may program the remote to operate the lights. 1. With the door closed, press and hold a small remote button that you want to control the light. 2. Press and hold the Light button on the door control. 3. While holding the Light button, press and hold the Lock button on the door control. 4. After the opener lights flash, release all buttons.

LOCK

Designed to prevent operation of the door from hand-held remote controls. However, the door will open and close from the Door Control, the Outdoor Key Switch and the Keyless Entry Accessories. To activate, press and hold the Lock button for 2 seconds. To turn off, press and hold the Lock button again for 2 seconds. The Lock feature will also turn off whenever the “learn” button on the motor unit panel is activated. Motion Sensing (Automatic Light Feature): The opener light will turn on automatically when a person enters the garage. When a person walks in front of the door control, the light will come on for five minutes, then shut off. This feature works by detecting body heat.

To disable this feature, push the motion sensing button on the side of the door control. We recommend that you disable the motion sensor when using the opener lights as working lights. Otherwise, they will turn off automatically if you are working beyond the sensors range.

Show 9 more labels / short text on this page
Automatic Light · Push Bar · On/Off Prog <Learn> · Hour · Minute · Language · Light Button · Degrees (F/C) · Lock Button
Page 28 of the Chamberlain 3885C user manual — NOTICE
Page 28 · cliquer pour agrandir
Page 28

To Open the Door Manually

  • To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
  • If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
  • NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
  • NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.

The door should be fully closed if possible. Pull down on the emergency release handle and lift the door manually. To reconnect the door to the opener, press the door control push bar.

Emergency Release Handle (Pull Down)

NOTICE

MANUAL DISCONNECT

The lockout feature prevents the trolley from reconnecting automatically. Pull the emergency release handle down and back (toward the opener). The door can then be raised and lowered manually as often as necessary. To disengage the lockout feature, pull the handle straight down. The trolley will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote.

POSITION

Emergency Release Handle (Down and Back)

NOTICE

LOCKOUT POSITION

Trolley Release Arm · Trolley Release Arm

Page 29 of the Chamberlain 3885C user manual — MAINTENANCE SCHEDULE
Page 29 · cliquer pour agrandir
Page 29

THE REMOTE CONTROL BATTERY

CARE OF YOUR OPENER

LIMIT AND FORCE ADJUSTMENTS: Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation. Pages 23 and 24 refer to the limit and force adjustments. Only a screwdriver is required. Follow the instructions carefully. Repeat the safety reverse test (Adjustment Step 3, page 25) after any adjustment of limits or force.

FORCE CONTROLS

  • To prevent possible SERIOUS INJURY or DEATH:
  • NEVER allow small children near batteries.
  • If battery is swallowed, immediately notify doctor.

KG KG

The lithium battery should produce power for up to 5 years. To replace battery, use the visor clip or screwdriver blade to pry open the case as shown. Insert battery positive side up (+). Dispose of old battery properly.

LIMIT CONTROLS

Battery positive side up (+)

MAINTENANCE SCHEDULE

NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

  • Once a Month
  • Manually operate door. If it is unbalanced or binding, call a trained door systems technician.
  • Check to be sure door opens and closes fully. Adjust limits and/or force if necessary (see pages 23 and 24).
  • Repeat the safety reverse test. Make any necessary adjustments (see Adjustment Step 3).

Once a Year • Oil door rollers, bearings and hinges. The opener does not require additional lubrication. Do not grease the door tracks.

Page 30 of the Chamberlain 3885C user manual — KG
Page 30 · cliquer pour agrandir
Page 30

HAVING A PROBLEM?

  • 1. My door will not close and the light bulbs blink on my motor unit: The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction.
  • Verify the safety sensors are properly installed, aligned and free of any obstructions. Refer to Installation Step 10: Install The Protector System ® .
  • Check diagnostic LED for flashes on the motor unit then refer to the Diagnostic Chart on the following page.

KG

KG

"Learn" Button LED or Diagnostic LED

  • 2. My remotes will not activate the door:
  • Verify your door control is not blinking. If it is blinking, deactivate the Lock Mode following the instructions for Using the Wall Mounted Door Control.
  • Reprogram remotes following the programming instructions. Refer to Programming .
  • If remote will still not activate your door, check diagnostic LED for flashes on motor unit then refer to Diagnostic Chart on the following page.

Receiving Eye Safety Reversing Sensor (Green Indicator Light) Sending Eye Safety Reversing Sensor (Amber Indicator Light)

  • 6. My motor unit hums briefly:
  • First verify that the trolley is against the stop bolt.
  • Release the door from the opener by pulling the Emergency Release Rope.
  • Manually bring the door to a closed position.
  • Loosen the belt by adjusting the outer nut 4 to 5 turns. This relieves the tension.
  • Run the motor unit from the remote control or door control. The trolley should travel towards the door and stop. If the trolley re-engages with the door, pull the Emergency Release Rope to disengage.
  • Decrease the UP travel by turning the UP Travel adjustment screw 2 full turns away from the arrow.
  • 3. My door reverses for no apparent reason: Repeat safety reverse test after adjustments to force or travel limits. The need for occasional adjustment for the force and limit settings is normal. Weather conditions in particular can affect door travel.
  • Manually check door for balance or any binding problems.
  • Refer to Adjustment Step 2, Adjust the Force.
4. My door reverses for no apparent reason after fully closing and touching the floor: Repeat safety reverse test after adjustments to force or travel limits. The need for occasional adjustment for the force and limit settings is normal. Weather conditions in particular can affect door travel. • Refer to Adjustment Step 1, Adjust the UP and DOWN Travel Limits. Decrease down travel by turning down limit adjustment screw clockwise.

1-1/4" (3.18 cm)

5. My lights will not turn off when door is open: • The garage door opener is equipped with a security light feature. This feature activates the light on when the safety sensor beam has been obstructed. Refer to Operation section; Using the Wall Mounted Door Control, Light Feature.
  • Re-Tighten the outer nut until the trolley spring is approximately 1-1/4" (3.18 cm) in length.
  • If the trolley does not move away from the bolt, repeat the steps above.

Bell Wire · Safety Reversing Sensor · Trolley

Page 31 of the Chamberlain 3885C user manual — 6 FLASHES
Page 31 · cliquer pour agrandir
Page 31

5 Diagnostics Located On Motor Unit

KG

KG

"Learn" Button LED or Diagnostic LED

Your garage door opener is programmed with self-diagnostic capabilities. The “Learn” button/diagnostic LED will flash a number of times then pause signifying it has found a potential issue. Consult Diagnostic Chart below. Diagnostic Chart

1 FLASH

  • Symptom: One or both of the Indicator lights on the safety sensors do not glow steady.
  • Inspect sensor wires for a short (staple in wire), correct wiring polarity (black/white wires reversed), broken or disconnected wires, replace/attach as needed.
  • Disconnect all wires from back of motor unit.
  • Remove sensors from brackets and shorten sensor wires to 1-2 ft. (30-60 cm) from back each of sensor.
  • Reattach sending eye to motor unit using shortened wires. If sending eye indicator light glows steadily, attach the receiving eye.
  • Align sensors, if the indicator lights glow replace the wires for the sensors. If the sensor indicator lights do not light, replace the safety sensors.

Safety reversing sensors wire open (broken or disconnected).

OR

2 FLASHES

Safety reversing sensors wire shorted or black/white wire reversed.

3 FLASHES

  • Symptom: LED is not lit on door control.
  • Inspect door control/wires for a short (staple in wire), replace as needed.
  • Disconnect wires at door control, touch wires together. If motor unit activates, replace door control.
  • If motor unit does not activate, disconnect door control wires from motor unit. Momentarily short across red and white terminals with jumper wire. If motor unit activates, replace door control wires.

Door control or wire shorted.

4 FLASHES

  • Symptom: Sending indicator light glows steadily, receiving indicator light is dim or flashing.
  • Realign receiving eye sensor, clean lens and secure brackets.
  • Verify door track is firmly secured to wall and does not move.

Safety reversing sensors slightly misaligned (dim or flashing LED).

5 FLASHES

  • Symptom: Motor has over heated; the motor unit does not operate or trolley is stuck on stop bolt = Motor unit hums briefly; RPM Sensor = Short travel 6-8" (15-20 cm).
  • Unplug unit to reset. Try to operate motor unit, check diagnostic code.
  • If it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace RPM sensor.
  • If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and retry. If motor unit still will not operate replace logic board.

Motor overheated or possible RPM sensor failure. Unplug to reset.

Symptom: Motor unit doesn’t operate. • Replace logic board because motor rarely fails. Motor Circuit Failure. Replace Receiver Logic Board.

6 FLASHES

Show 4 more labels / short text on this page
Bell Wire · Installed Safety Reversing · Sensor · Safety Reversing Sensor
Page 32 of the Chamberlain 3885C user manual — To Erase All Codes From Motor
Page 32 · cliquer pour agrandir
Page 32

PROGRAMMING

NOTICE: If this Security✚® garage door opener is operated with a non-rolling code transmitter, the technical measure in the receiver of the garage door opener, which provides security against code-theft devices, will be circumvented. The owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non-rolling code transmitter to circumvent that technical measure.

Your garage door opener has already been programmed at the factory to operate with your hand-held remote control. The door will open and close when you press the large push button. Below are instructions for programming your opener to operate with additional Security✚® remote controls.

To Add or Reprogram a Hand-held Remote Control

USING THE “LEARN” BUTTON TO ADD ADDITIONAL REMOTE CONTROLS USING THE LCD CONTROL CONSOLE

1. Press and release the “learn” button on the motor unit. The learn indicator light will glow steadily for 30 seconds.
1. Press the Prog button on the LCD/Motion Detecting Control Console.

LOCK LIGHT

2. Press the Prog button again to confirm Learn Mode.
2. Within 30 seconds, press and hold the button on the hand-held remote* that you wish to operate your garage door.

LOCK LIGHT

3. Press the button on the hand-held remote that you wish to operate your garage door.
3. Release the button when the motor unit lights blink. It has learned the code. If light bulbs are not installed, two clicks will be heard.
4. When the motor unit lights blink, it has learned the code. If light bulbs are not installed, two clicks will be heard.

To Erase All Codes From Motor

*3-Button Remotes

Unit Memory

If provided with your garage door opener, the large button is factory programmed to operate it. Additional buttons on any Security✚® 3-Button remote or compact remote can be programmed to operate other Security✚®

To deactivate any unwanted remote, first erase all codes: Press and hold the “learn” button on motor unit until the learn indicator light goes out (approximately 6 seconds). All previous codes are now erased. Reprogram each remote or keyless entry you wish to use.

garage door openers.

Page 33 of the Chamberlain 3885C user manual — LOCK LIGHT
Page 33 · cliquer pour agrandir
Page 33

To Add, Reprogram or Change a Keyless Entry PIN

USING THE “LEARN” BUTTON USING THE LCD MOTION DETECTING DOOR CONTROL

1. Press and release the “learn” button on motor unit. The learn indicator light will glow steadily for 30 seconds.
1. Press the Prog button on the LCD/Motion Detecting Control Console.
2. Within 30 seconds, enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold the ENTER button. 3. Release the button when the motor unit lights blink. It has learned the code. If light bulbs are not installed, two clicks will be heard.

LOCK LIGHT

2. Press the Prog button again to confirm Learn Mode.

LOCK LIGHT

3. Enter a four digit personal identification number (PIN) of your choice on the keypad. Then press enter.

To change an existing, known PIN If the existing PIN is known, it may be changed by one person without using a ladder. 1. Press the four buttons for the present PIN, then press and hold the # button. The opener light will blink twice. Release the # button. 2. Press the new 4-digit PIN you have chosen, then press Enter. The motor unit lights will blink once when the PIN has been learned. Test by pressing the new PIN, then press Enter. The door should move.

4. When the motor unit lights blink, it has learned the code. If light bulbs are not installed, two clicks will be heard.
2. Press the temporary 4-digit PIN you have chosen, then press Enter. The opener light will blink four times. 3. To set the number of hours this temporary PIN will work, press the number of hours (up to 255), then press ✽ .

To set a temporary PIN You may authorize access by visitors or service people with a temporary 4-digit PIN. After a programmed number of hours or number of accesses, this temporary PIN expires and will no longer open the door. It can be used to close the door even after it has expired. To set a temporary PIN: 1. Press the four buttons for your personal entry PIN (not the last temporary PIN), then press and hold the ✽button. The opener light will blink three times. Release the button.

OR 3. To set the number of times this temporary PIN will work, press the number of times (up to 255), then press #. The opener light will blink once when the temporary PIN has been learned. Test by pressing the four buttons for the temporary PIN, then press Enter. The door should move. If the temporary PIN was set to a certain number of openings, remember that the test has used up one opening.To clear the temporary password, repeat steps 1-3, setting the number of hours or times to 0 in step 3.

One Button Close: Opener can be closed by pressing only the ENTER button if the one button close feature has been activated. This feature has been activated at the factory. To activate or deactivate this feature press and hold buttons 1 and 9 for 10 seconds. The keypad will blink twice when the one button close is active. The keypad will blink four times when one button close is deactivated.

Page 34 of the Chamberlain 3885C user manual — NOTICE
Page 34 · cliquer pour agrandir
Page 34

REPAIR PARTS

Rail Assembly Parts

KEY PART NO. NO. DESCRIPTION

1 4A1008 Master link kit 2 41B5424 Belt pulley bracket 3 41B3869-1 Complete trolley assembly 4 109B33 Trolley clip 5 2777BD One-piece T-rail 6 41A5434-11 Full belt assembly 7 41B4103 Tensioner assembly 8 83A11-2 Rail grease

Installation Parts

KEY PART NO. NO. DESCRIPTION

1 398LMC LCD Motion detecting door control console 2 373LMC 3-button remote control 3 10A20 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency Release rope & handle assembly. 6 41B4494-1 2-Conductor bell wire, white & white/red 7 41A5047-1 Door bracket w clevis pin & fastener 8 41A4353-1 Header bracket w/clevis pin & fastener 9 41A5034 Safety sensor kit (receiving and sending eyes) with 3' (.9 m) 2-conductor bell wire 10 178B34 Straight door arm section 11 178B35 Curved door arm section 12 41A5266-1 Safety sensor brackets (2) NOT SHOWN 101D173 Push bar for door control 41A2770-5 Installation hardware bag (includes hardware listed on page 5) 114A3340 Owner’s manual

NOTICE

CEILING MOUNT ONLY

UP

Page 35 of the Chamberlain 3885C user manual — KEY PART NO. NO. DESCRIPTION
Page 35 · cliquer pour agrandir
Page 35

Motor Unit Assembly Parts

19 8A

8B

14 13 12

(Down) Contact LIMIT SWITCH ASSEMBLY

DN

UP

(Up) Contact Center Limit Contact

KEY PART NO. NO. DESCRIPTION

KEY PART NO. NO. DESCRIPTION

1 41A4371 Belt Cap 2 41A4885-5 Gear and sprocket assembly Complete with: Spring washer, thrust washer, retaining ring, bearing plate, roll pins (2), drive gear and worm gear, helical gear w/retainer and grease 3 41A2817 Drive/worm gear kit w/grease, roll pins (2) 4 41B4245-1 Line cord 5 41A5484 End panels w/all labels 6 4A1344 Light socket 7 108D79 Lens 8A 30B530 Capacitor 56uF 8B 30B529 Capacitor 40uF 8C 41A5637 Resistor 9 41A3150 Terminal block w/screws 10 41D5563-1 Universal replacement motor & bracket assembly Complete with: Motor, worm, bracket, gear case, bearing assembly, RPM sensor

11 41A5633-6 Cover 12 41A2818 Limit switch drive & retainer 13 41D3452 Limit switch assembly 14 41A5532 Gear case 15 41A2822-1 Interrupter cup assembly 16 41C4398A RPM sensor assembly 17 41AB075-2 Receiver logic board assembly. Complete with: Logic board, end panel w/all labels, light socket 18 41C5588 High voltage wire harness assembly 41C5587 Low voltage wire harness assembly 19 41D180-1 End panel w/all labels

NOT SHOWN 41A2826 Motor shaft bearing kit 41A2825 Opener assembly hardware kit (includes screws not designated by a number in illustration)

Show 4 more labels / short text on this page
Brown Wire · Grey Wire · Drive Gear · Yellow Wire
Page 36 of the Chamberlain 3885C user manual — 902LMC/903LMC
Page 36 · cliquer pour agrandir
Page 36
Chamberlain 3885C — Accessories diagram (page 36)
Fig. 27 · Accessories

1702LMC Outside Quick Release: Required for a garage with NO access door. Enables homeowner to open garage door manually from outside by disengaging trolley.

395LMC

Remote Light Control: Enables homeowner to turn on a lamp, television or other appliance from their car with their garage door opener remote or from anywhere in their home with an additional LiftMaster Security✚® remote.

373LMC 3-Button Security ✚ ® Remote Control:

8 Foot (2.4 m) Complete Rail: To allow an 8 foot (2.4 m) door to open fully.

Includes visor clip.

374LMC

4-Button Security✚® Remote Control:

10 Foot (3 m) Complete Rail: To allow a 10 foot (3 m) door to open fully.

Includes visor clip.

370LMC

3-Button Mini-Remote Control with Security✚®: With key ring and fastening strip.

Extension Brackets: (Optional) For safety sensor installation onto the wall or floor.

378LMC

Wireless Door Control: Push bar, light feature and auxiliary button. Includes battery.

377LMC SECURITY ✚

® Keyless Entry: Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard. Also can add a temporary password for visitors or service persons. This temporary password can be limited to a programmable number of hours or entries. Opener can be closed by pressing only the ENTER button if the one button close feature has been activated.

LOCK LIGHT

915LMC

Garage Door Monitor: Security for the largest door of your home! Tells you if your garage door is open or closed. Monitors up to 4 garage doors by adding additional sensor modules.

CLOSED

OPEN

916LMC

Garage Door Monitor Sensor: Additional accessory sensor for homes with multiple garage doors.

902LMC/903LMC

2 & 3 Door Multi-Function Wall Control: Ideal for homes with up to three garage doors. Combine up to three controls into one wall control panel for a neat compact appearance. Enhanced functions include Lock Feature to lock out outside radio signals while you are away from home and turn opener lights on or off from the control panel.

Page 37 of the Chamberlain 3885C user manual — NOTES
Page 37 · cliquer pour agrandir
Page 37

NOTES

Page 38 of the Chamberlain 3885C user manual — NOTES
Page 38 · cliquer pour agrandir
Page 38

NOTES

Page 39 of the Chamberlain 3885C user manual — NOTES
Page 39 · cliquer pour agrandir
Page 39

NOTES

Page 40 of the Chamberlain 3885C user manual — LIFTMASTER GARAGE DOOR OPENER FIVE-YEAR LIMITED WARRANTY
Page 40 · cliquer pour agrandir
Page 40

LIFTMASTER SERVICE IS

HOW TO ORDER

ON CALL

REPAIR PARTS

Selling prices will be furnished on request or parts will

OUR LARGE SERVICE ORGANIZATION

be shipped at prevailing prices and you will be billed

SPANS AMERICA AND CANADA

accordingly.

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE

INSTALLATION AND SERVICE INFORMATION IS AS

THE FOLLOWING INFORMATION:

NEAR AS YOUR TELEPHONE. SIMPLY DIAL OUR TOLL FREE NUMBER:

  • PART NUMBER
  • PART NAME
  • MODEL NUMBER

1-800-528-9131

ADDRESS ORDERS TO: THE CHAMBERLAIN GROUP, INC.

Technical Support Group 6020 S. Country Club Road Tucson, Arizona 85706

www.liftmaster.com

For professional installation, parts and service,

SERVICE INFORMATION

contact your local LIFTMASTER/CHAMBERLAIN dealer. Look for him in the Yellow Pages, or call our

TOLL FREE NUMBER: 1-800-528-9131

Service number for a list of dealers in your area.

LIFTMASTER GARAGE DOOR OPENER FIVE-YEAR LIMITED WARRANTY

LIFETIME MOTOR AND BELT LIMITED WARRANTY

The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of five years from the date of purchase and that the motor is free from defect in materials and/or workmanship for the lifetime of the product. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this warranty in its entirety.

If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-9131, toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.

THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, AND OF ANY OTHER OBLIGATIONS OR LIABILITY ON SELLER’S PART. THIS LIMITED WARRANTY DOES NOT COVER NON- DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, REPLACEMENT OF BATTERIES AND LIGHT BULBS OR UNITS INSTALLED FOR NON- RESIDENTIAL USE.

THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.

UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.

Some Provinces do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from province to province.

© 2006, The Chamberlain Group, Inc. 114A3340 All Rights Reserved

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
Motor Circuit Failure. Replace Receiver Logic Board. p.31

Poser une question sur : Chamberlain 3885C

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Chamberlain 3885C

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Chamberlain 3885C manuel PDF

80 pages·7.7 MB·Ouvre-porte de garage·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…