The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com


Fasten the manual near the garage door after installation.
The door WILL NOT CLOSE unless the Protector System® is connected and
Periodic checks of the opener are required to ensure safe operation.
The model number label is located on the front panel of your opener.


door. If balanced, it should stay in place, supported entirely by its springs. 2. Raise and lower the door to see if there is any
binding or sticking. If your door binds, sticks, or is out of balance, call a trained door systems technician.
Tools needed
One-Piece Door
During assembly, installation and adjustment of the opener, instructions will call for hand tools as illustrated below.
3/16", 5/16" and 5/32" Drill Bits
Screwdriver Adjustable End Wrench 1/2" and 7/16" Sockets and Wrench

Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener.
FINISHED CEILING
Support bracket & fastening hardware is required. See page 12.
Horizontal and vertical reinforcement is needed for lightweight garage doors (fiberglass, steel, aluminum, door with glass panels, etc.). See page 19 for details.
Slack in chain tension is normal when garage door is closed.
—
Vertical Centerline of Garage Door
Gap between floor and bottom of door must not exceed 1/4" (6 mm).
ONE-PIECE DOOR WITHOUT TRACK
Support bracket & fastening hardware is required. See page 12.
Slack in chain tension is normal when garage door is closed.
Slack in chain tension is normal when garage door is closed.
Safety Reversing Sensor Gap between floor and bottom of door must not exceed 1/4" (6 mm).
Gap between floor and bottom of door must not exceed 1/4" (6 mm).


Your garage door opener is packaged in two cartons which contain the motor unit and all parts illustrated below. Accessories will depend on the model purchased.
If anything is missing, carefully check the packing material. Parts may be stuck in the foam. Hardware for installation is also listed below.

To avoid SERIOUS damage to garage door opener, use ONLY those bolts/fasteners mounted in the top of the opener.
BOLT
ASSEMBLY STEP 2 Attach the Chain to the Sprocket and Install the Sprocket Cover
Washered Bolts 5/16"-18x1/2" Sprocket
BOLT

To Tighten Outer Nut
To Tighten Inner Nut
Mid Length of Rail
IMPORTANT INSTALLATION INSTRUCTIONS
WARNING WARNING
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS. 2. Install garage door opener only on properly balanced and lubricated garage door. An improperly balanced door may not reverse when required and could result in SEVERE INJURY or DEATH. 3. All repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener. 4. Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement. 5. Install garage door opener 7 feet (2.13 m) or more above floor. 6. Mount emergency release handle 6 feet (1.83 m) above floor. 7. NEVER connect garage door opener to power source until instructed to do so.

Vertical Centerline of Garage Door
Track 2" (5 cm)
Highest Point of Travel
Highest Point of Travel
One-piece door with horizontal track
Highest Point of Travel
Highest Point of Travel Door


You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements. Do not install the header bracket over drywall. If installing into masonry, use concrete anchors (not provided).
The nail hole is for positioning only. You must use lag screws to mount the header bracket.

The nail hole is for positioning only. You must use lag screws to mount the header bracket.
Lag Screw 5/16"-9x1-5/8"




To prevent damage to garage door, rest garage door opener rail on 2x4 placed on top section of door.
Follow instructions which apply to your door type as illustrated.
2x4 is used to determine the correct mounting height from ceiling.


2x4 is used to determine the correct mounting height from ceiling.
Rail · Door · Trolley Release Arm

To avoid possible SERIOUS INJURY from a falling garage door opener, fasten it SECURELY to structural supports of the garage. Concrete anchors MUST be used if installing any brackets into masonry.
Three representative installations are shown. Yours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On finished ceilings (Figure 2 and Figure 3), attach a sturdy metal bracket to structural supports before installing the opener. This bracket and fastening hardware are not provided. 1. Measure the distance from each side of the motor unit to the structural support. 2. Cut both pieces of the hanging bracket to required lengths. 3. Drill 3/16" pilot holes in the structural supports. 4. Attach one end of each bracket to a support with 5/16"-18x1-7/8" lag screws. 5. Fasten the opener to the hanging brackets with 5/16"-18x7/8" hex bolts, lock washers and nuts. 6. Check to make sure the rail is centered over the door (or in line with the header bracket if the bracket is not centered above the door). 7. Remove the 2x4. Operate the door manually. If the door hits the rail, raise the header bracket. 8. Grease the top and underside of the rail surface where the trolley slides with rail grease. NOTE: DO NOT connect power to opener at this time.
Measure Distance Lag Screws 5/16"-18x1-7/8"
Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
(Not Provided) Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
Hex Bolt 5/16"-18x7/8" Nut 5/16"-18 Lock Washer 5/16"
(Not Provided) Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18

Locate door control within sight of door at a minimum height of 5 feet (1.5 m) where small children cannot reach, and away from moving parts of door and door hardware. The installation surface must be smooth and flat. If installing into drywall (Figure 1), drill 5/32" holes and use anchors provided. For pre-wired installations (as in new home construction), it may be mounted to a single gang box (Figure 2). NOTE: After installation, a green or amber indicator light behind the cover will indicate proper connection. If not lit, the Lock and Light features will not function (reverse wires to correct). 1. Strip 7/16" (11 mm) of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color: white wire to WHT and white/red wire to the RED (Figure 3). 2. Remove cover by gently prying at slot in the top of the cover with a small flat head screwdriver (Figure 4). Fasten with 6ABx1-1/4" self-tapping screws (drywall installation) or 6-32x1" machine screws (into gang box) as follows: • Drill and install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface. • Position bottom of door control on screw head and
Insulated Staples Screw 6ABx1-1/4" (standard installation)
slide down to secure. Adjust screw for snug fit. • Install top screw with care to avoid cracking plastic
housing. Do not overtighten. • Insert bottom tabs and snap on cover. NOTE: The push bar may stick if the door control is not
PRE-WIRED INSTALLATION
mounted on a smooth surface. If a click is not heard when pressing the push bar, loosen the two mounting screws or relocate the door control to a smoother surface. 3. (Standard installation only) Run bell wire up wall and across ceiling to motor unit. Use insulated staples to secure wire in several places. Do not pierce wire with a staple, creating a short or open circuit. 4. Strip 7/16" (11 mm) of insulation from end of bell wire. Connect bell wire to the quick-connect terminals as follows: white to white and white/red to red (Figure 5). NOTE: When connecting multiple door controls to the
LIGHT LOCK
LIGHT To Replace Insert Bottom Tabs First
To Replace Insert Bottom Tabs First
24 Volt 2-Conductor Bell Wire in Gang Box
Figure 4 REMOVE COVER
opener, twist same color wires together. Insert wires into quick-connect holes: white to white and red/white to red. 5. Use tacks or staples to permanently attach entrapment warning label to wall near door control, and manual release/safety reverse test label in a prominent location on inside of garage door. NOTE: DO NOT connect power and operate opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.
LIGHT
To release or insert wire, push in tab with screwdriver tip Door Control Connections
KG
Strip wire 7/16" (11 mm)

100 Watt (Max) Standard Light Bulb
100 Watt (Max) Standard Light Bulb

To avoid installation difficulties, do not run the opener at this time. To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet. If the plug doesn’t fit into the outlet you have, contact a qualified electrician to install the proper outlet.
RIGHT WRONG

The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction.
IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR When properly connected and aligned, the sensor will detect an obstacle in the path of its electronic beam. The sending eye (with an amber indicator light) transmits an invisible light beam to the receiving eye (with a green indicator light). If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to full open position, and the opener lights will flash 10 times. The units must be installed inside the garage so that the sending and receiving eyes face each other across the door, no more than 6" (15 cm) above the floor. Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens. The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware.
If it is necessary to mount the units on the wall, the brackets must be securely fastened to a solid surface such as the wall framing. Extension brackets (see accessories) are available if needed. If installing in masonry construction, add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary. The invisible light beam path must be unobstructed. No part of the garage door (or door tracks, springs, hinges, rollers or other hardware) may interrupt the beam while the door is closing.

Safety Reversing Sensor 6" (15 cm) max. above floor Safety Reversing Sensor 6" (15 cm) max. above floor

INSTALLING THE BRACKETS Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the floor. They may be installed in one of three ways, as follows.
Garage door track installation (preferred): • Slip the curved arms over the rounded edge of each door track, with the curved arms facing the door. Snap into place against the side of the track. It should lie flush, with the lip hugging the back edge of the track, as shown in Figure 1. If your door track will not support the bracket securely, wall installation is recommended.
Fasten Wood Block to Wall with Lag Screws (Not Provided)
Indicator Light Sensor Bracket
Lag Screws (Not Provided)
Extension Bracket (See Accessories)
(Provided with Extension Bracket)
(Provided with Extension Bracket)
HARDWARE SHOWN ACTUAL SIZE
Attach with Concrete Anchors (Not Provided)
Wing Nut 1/4"-20 Staples Carriage Bolt 1/4"-20x1/2"

Figure 5 MOUNTING AND WIRING THE SAFETY REVERSING SENSORS • Slide a 1/4"-20x1/2" carriage bolt head into the slot on

ALIGNING THE SAFETY REVERSING SENSORS • Plug in the opener. The indicator lights in both the


Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit.
Follow instructions which apply to your door type as illustrated below or on the following page. A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports. A vertical reinforcement brace should cover the height of the top panel. Figure 1 shows one piece of angle iron as the horizontal brace. For the vertical brace, 2 pieces of angle iron are used to create a U-shaped support. The best solution is to check with your garage door manufacturer for an opener installation door reinforcement kit. NOTE: Many door reinforcement kits provide for direct attachment of the clevis pin and door arm. In this case you will not need the door bracket; proceed to Step 12.
SECTIONAL DOORS 1. Center the door bracket on the previously marked vertical centerline used for the header bracket installation. Note correct UP placement, as stamped inside the bracket. 2. Position the top edge of the bracket 2"-4" (5-10 cm) below the top edge of the door, OR directly below any structural support across the top of the door. 3. Mark, drill holes and install as follows, depending on your door’s construction:
HORIZONTAL AND VERTICAL REINFORCEMENT IS NEEDED FOR LIGHTWEIGHT GARAGE DOORS (FIBERGLASS, ALUMINUM, STEEL, DOORS WITH GLASS PANEL, ETC.). (NOT PROVIDED)
Vertical Centerline of Garage Door
Vertical Reinforcement (Not Provided)
Vertical Centerline of Garage Door
Vertical Centerline of Garage Door
UP
Metal, insulated or light weight factory reinforced doors: • Drill 3/16" fastening holes. Secure the door bracket using the self-threading screws. (Figure 3)
Inside Edge of Door or Reinforcement Board
Wood Doors: • Use top and bottom or side to side door bracket holes. Drill 5/16" holes through the door and secure bracket with 5/16"x2" carriage bolts, lock washers and nuts (not provided). (Figure 4) NOTE: The 1/4"-14x5/8" self-threading screws are not intended for use on wood doors.
Vertical Centerline of Garage Door
Vertical Centerline of Garage Door
HARDWARE SHOWN ACTUAL SIZE

ACTUAL SIZE
carriage bolts, lock washers and nuts (not provided) or 5/16"x1-1/2" lag screws (not provided) depending on your installation needs.

HORIZONTAL AND VERTICAL REINFORCEMENT IS NEEDED FOR LIGHTWEIGHT GARAGE DOORS (FIBERGLASS, ALUMINUM, STEEL, DOORS WITH GLASS PANEL, ETC.). (NOT PROVIDED)
For a door with no exposed framing, or for the optional installation, use lag screws 5/16"x1-1/2" (Not Provided) to fasten door bracket.
Self-Threading Screw 1/4"-14x5/8"

Follow instructions which apply to your door type as illustrated below and on the following page.
Lock Washer 5/16" Nut 5/16"-18 Ring Fastener
Hex Bolt 5/16"-18x7/8" Clevis Pin 5/16"x1" (Trolley) Clevis Pin 5/16"x1-1/4" (Door Bracket)

ALL ONE-PIECE DOORS 1. Assemble the door arm, Figure 4: • Fasten the straight and curved door arm sections
Nuts 5/16"-18 Lock Washers 5/16"
together to the longest possible length (with a 2 or 3 hole overlap). • With the door closed, connect the straight door arm
- Press the Door Control push button. The trolley will
travel to the fully closed position. - Manually close the door and lift the door arm to the
to the trolley, the travel limits must be adjusted. Limit adjust ment screws are located on the left side panel as shown on page 23. Follow adjustment procedures below. • Open door adjustment: decrease UP travel limit - Turn the UP limit adjustment screw counter-clockwise
trolley. The arm should touch the trolley just ahead of the door arm connector hole. Refer to the fully closed trolley/door arm positions in the illustration. If the arm is behind the connector hole, adjust the limit further. One full turn equals 2" (5 cm) of trolley travel. 3. Connect the door arm to the trolley: • Close the door and join the curved arm to the
4 turns. - Press the Door Control push button. The trolley will
travel to the fully open position. - Manually raise the door to the open position (parallel
to the floor), and lift the door arm to the trolley. The arm should touch the trolley just in back of the door arm connector hole. Refer to the fully open trolley/ door arm positions in the illustration. If the arm does not extend far enough, adjust the limit further. One full turn equals 2" (5 cm) of trolley travel. • Closed door adjustment: decrease DOWN travel
door has a slight "backward" slant in full open position as shown in the illustration, decrease the UP limit until the door is parallel to the floor. NOTE: When setting the up limit on the following page, the door should not have a "backward" slant when fully open as illustrated below. A slight backward slant will cause unnecessary bucking and/or jerking operation as the door is being opened or closed from the fully open position.
limit - Turn the DOWN limit adjustment screw clockwise
4 complete turns.
Inner Trolley Figure 5
Door Arm Connector Hole
Door Arm Correct Angle
Door with Backward Slant (Incorrect)

To prevent damage to vehicles, be sure fully open door provides adequate clearance.
clockwise. One turn equals 2" (5 cm) of travel. NOTE: To prevent the trolley from hitting the cover
Left Side Panel Limit Adjustment Screws
protection bolt, keep a minimum distance of 2-4" (5 cm - 10 cm) between the trolley and the bolt.
Step 2.
screw counterclockwise. One turn equals 2" (5 cm) of travel. If door still won't close completely and the trolley bumps
Sensors are either not installed, misaligned, or obstructed. See Troubleshooting, page 18. Test the door for binding: Pull the emergency release
into the pulley bracket (page 4), try lengthening the door arm (page 21) and decreasing the down limit.
handle. Manually open and close the door. If the door is binding or unbalanced, call for a trained door systems technician. If the door is balanced and not binding, adjust the DOWN (close) force. See Adjustment Step 2.
screw clockwise. One turn equals 2" (5 cm) of travel.
Cover Protection Bolt · 2-4" (5-10 cm) · Adjustment Label

Force adjustment controls are located on the back panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door. If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction. Weather conditions can affect the door movement, so occasional adjustment may be needed. The maximum force adjustment range is about 3/4 of a complete turn. Do not force controls beyond that point. Turn force adjustment controls with a screwdriver. NOTE: If anything interferes with the door’s upward travel, it will stop. If anything interferes with the door’s downward travel (including binding or unbalanced doors), it will reverse.
FORCE ADJUSTMENT LABEL
KG KG
Open Force Close Force
Force Adjustment Controls · Back Panel · Antenna

ADJUST • If the door stops on the obstruction, it is not traveling far enough in the down direction. Increase the DOWN limit by turning the DOWN limit adjustment screw counterclockwise 1/4 turn. NOTE: On a sectional door, make sure limit adjustments
1-1/2" (3.8 cm) board (or a 2x4 laid flat)
Without a properly installed safety reversing sensor, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
Safety Reversing Sensor Safety Reversing Sensor

IMPORTANT SAFETY INSTRUCTIONS
WARNING WARNING
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS. 2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls. 3. ONLY activate garage door when it can be seen clearly, it is properly adjusted, and there are no obstructions to door travel. 4. ALWAYS keep garage door in sight until completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY OPEN DOOR. 6. If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. 7. NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
rope knot becomes untied, you could fall. 9. If one control (force or travel limits) is adjusted, the
other control may also need adjustment. 10. After ANY adjustments are made, the safety reversal system MUST be tested. 11. Safety reversal system MUST be tested every month. Garage door MUST reverse on contact with 1-1/2" high (3.8 cm) high object (or a 2x4 laid flat) on the floor. 12. ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED (see page 3). An improperly balanced door may not reverse when required and could result in SEVERE INJURY or DEATH. 13. All repairs to cables, spring assemblies and other hardware, all of which are under EXTREME tension, MUST be made by a trained door systems technician. 14. ALWAYS disconnect electric power to garage door opener BEFORE making ANY repairs or removing covers.
6. If obstructed while opening, the door will stop. 7. If fully open, the door will not close when the beam is broken. The sensor has no effect in the opening cycle. If the sensor is not installed, or is misaligned, the door won’t close from a hand-held remote. However, you can close the door with the Door Control, the Outside Keylock, or Keyless Entry, if you activate them until down travel is complete. If you release them too soon, the door will reverse. The opener lights will turn on under the following conditions: when the opener is initially plugged in; when power is restored after interruption; when the opener is activated. They will turn off automatically after 4-1/2 minutes or provide constant light when the Light feature on the Multi- Function Door Control is activated. Bulb size is A19. Bulb power is 100 watts maximum. Security✚® light feature: Lights will also turn on when someone walks through the open garage door. With a Multi-Function Door Control, this feature may be turned off as follows: With the opener lights off, press and hold the light button for 10 seconds, until the light goes on, then off again. To restore this feature, start with the opener lights on, then press and hold the light button for 10 seconds until the light goes off, then on again.
Your Security✚® opener and hand-held remote control have been factory-set to a matching code which changes with each use, randomly accessing over 100 billion new codes. Your opener will operate with up to eight Security✚® remote controls and one Security✚® Keyless Entry System. If you purchase a new remote, or if you wish to deactivate any remote, follow the instructions in the Programming section.
When the opener is activated (with the safety reversing sensor correctly installed and aligned) 1. If open, the door will close. If closed, it will open. 2. If closing, the door will reverse. 3. If opening, the door will stop. 4. If the door has been stopped in a partially open position, it will close. 5. If obstructed while closing, the door will reverse. If the obstruction interrupts the sensor beam, the opener lights will blink for five seconds.

B) To operate one door using all three buttons on the
hand-held remote: You may program the remote to openthe door with the large button, close it with the middle button, and stop the door’s movement with the third button. NOTE: If remote is already programmed, you must first erase all codes. See Programming. 1. With the door closed, press and hold the large remote push button. 2. Press and hold the Lock button on the door control. 3. Press and hold the door control push bar. 4. After the opener lights flash, release all buttons.
THE MULTI-FUNCTION DOOR CONTROL Press the push button to open or close the door. Press again to reverse the door during the closing cycle or to stop the door while it's opening.
Light feature Press the Light button to turn the opener light on or off. It will not control the opener lights when the door is in motion. If you turn it on and then activate the opener, the light will remain on for 4-1/2 minutes. Press again to turn it off sooner. The 4-1/2 minute interval can be changed to 1-1/2, 2-1/2, or 3-1/2 minutes as follows: Press and hold the Lock button until the light blinks (about 10 seconds). A single blink indicates that the timer is reset to 1-1/2 minutes. Repeat the procedure and the light will blink twice, resetting the timer to 2-1/2 minutes. Repeat again for a 3-1/2 minute interval, etc., up to a maximum of four blinks and 4-1/2 minutes.
LIGHT
To Open the Door Manually
Lock feature Designed to prevent operation of the door from hand-held remote controls. However, the door will open and close from the Door Control, the Outside Keylock and the Keyless Entry Accessories. To activate, press and hold the Lock button for 2 seconds. The push bar light will flash as long as the Lock feature is on. To turn off, press and hold the Lock button again for 2 seconds.The push bar light will stop flashing. The Lock feature will also turn off whenever the “learn” button on the motor unit panel is activated.
The door should be fully closed if possible. Pull down on the emergency release handle and lift the door manually. To reconnect the door to the opener, press the door control push bar.
Additional features when used with the 3-Button hand-held remote A) To control the opener lights: In addition to operating the door, you may program the remote to operate the lights. 1. With the door closed, press and hold a small remote button that you want to control the light. 2. Press and hold the Light button on the Multi-Function door control. 3. While holding the Light button, press and hold the Lock button on the door control. 4. After the opener lights flash, release all buttons.
Emergency Release Handle (Pull Down)
The lockout feature prevents the trolley from reconnecting automatically. Pull the emergency release handle down and back (toward the opener). The door can then be raised and lowered manually as often as necessary. To disengage the lockout feature, pull the handle straight down. The trolley will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote.
POSITION
Emergency Release Handle (Down and Back)
LOCKOUT POSITION

LIMIT AND FORCE ADJUSTMENTS: Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation. Pages 23 and 24 refer to the limit and force adjustments. Only a screwdriver is required. Follow the instructions carefully. Repeat the safety reverse test (Adjustment Step 3, page 25) after any adjustment of limits or force.
LIMIT CONTROLS
The lithium battery should produce power for up to 5 years. To replace battery, use the visor clip or screwdriver blade to pry open the case as shown. Insert battery positive side up (+). Dispose of old battery properly. Replace the battery with only 3V2032 coin cell batteries.
Battery positive side up (+)
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Twice a Year • Check chain tension. Disconnect trolley first. Adjust if necessary (See page 7).
Once a Year • Oil door rollers, bearings and hinges. The opener does not require additional lubrication. Do not grease the door tracks.

and free of any obstructions. Refer to Installation Step 10: Install The Protector System®. • Check diagnostic LED for flashes on the motor unit
Diagnostics Located On Motor Unit
then refer to the Diagnostic Chart on the following page.
LED or Diagnostic LED
deactivate the Lock Mode following the instructions for Using the Wall Mounted Door Control. • Reprogram remotes following the programming
instructions. Refer to Programming. • If remote will still not activate your door, check
Receiving Eye Safety Reversing Sensor (Green Indicator Light) Sending Eye Safety Reversing Sensor (Amber Indicator Light)
diagnostic LED for flashes on motor unit then refer to Diagnostic Chart on the following page.
problems. • Refer to Adjustment Step 2, Adjust the Force.
turns. This relieves the tension. • Run the motor unit from the remote control or door
control. The trolley should travel towards the door and stop. If the trolley re-engages with the door, pull the Emergency Release Rope to disengage. • Decrease the UP travel by turning the UP Travel
adjustment screw 2 full turns away from the arrow. • Re-tighten the outer nut so the chain is a 1/2" (13 mm)
Travel Limits. Decrease down travel by turning down limit adjustment screw clockwise.
above the base of the rail. (When the door is reconnected and closed, the chain will sag. This is normal.) • If the trolley does not move away from the bolt, repeat
the steps above.
light feature. This feature activates the light on when the safety sensor beam has been obstructed. Refer to Operation section; Using the Wall Mounted Door Control, Light Feature.
Bell Wire · “Learn” Button · Safety Reversing Sensor

Diagnostics Located On Motor Unit
LED or Diagnostic LED
Your garage door opener is programmed with self-diagnostic capabilities. The “Learn” button/diagnostic LED will flash a number of times then pause signifying it has found a potential issue. Consult Diagnostic Chart below. Diagnostic Chart
Safety reversing sensors wire open (broken or disconnected).
2 FLASHES
Safety reversing sensors wire shorted or black/ white wire reversed.
Door control or wire shorted.
Safety reversing sensors slightly misaligned (dim or flashing LED).
Motor overheated or possible RPM sensor failure. Unplug to reset.
Symptom: Motor unit doesn’t operate. • Replace logic board because motor rarely fails. Motor Circuit Failure. Replace Receiver Logic Board.

NOTICE: If this Security✚® garage door opener is operated with a non-rolling code transmitter, the technical measure in the receiver of the garage door opener, which provides security against code-theft devices, will be circumvented. The owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non-rolling code transmitter to circumvent that technical measure.
Your garage door opener has already been programmed at the factory to operate with your hand-held remote control. The door will open and close when you press the large push button. Below are instructions for programming your opener to operate with additional Security✚® remote controls.
KG
KG
LOCK
LIGHT
While holding the remote button,
press and hold the LIGHT button on the Multi-Function Door Control.
LIGHT
LIGHT

*3-Button Remotes If provided with your garage door opener, the large button is factory programmed to operate it. Additional buttons on any Security✚® 3-Button remote or compact remote can be programmed to operate other Security✚® garage door openers.
To deactivate any unwanted remote, first erase all codes: Press and hold the “learn” button on motor unit until the learn indicator light goes out (approximately 6 seconds). All previous codes are now erased. Reprogram each remote or keyless entry you wish to use.

LIGHT
LIGHT
LIGHT
To change an existing, known PIN If the existing PIN is known, it may be changed by one person without using a ladder. 1. Press the four buttons for the present PIN, then press and hold the # button. The opener light will blink twice. Release the # button. 2. Press the new 4-digit PIN you have chosen, then press Enter. The motor unit lights will blink once when the PIN has been learned. Test by pressing the new PIN, then press Enter. The door should move.
OR 3. To set the number of times this temporary PIN will work, press the number of times (up to 255), then press #. The opener light will blink once when the temporary PIN has been learned. Test by pressing the four buttons for the temporary PIN, then press Enter. The door should move. If the temporary PIN was set to a certain number of openings, remember that the test has used up one opening.To clear the temporary password, repeat steps 1-3, setting the number of hours or times to 0 in step 3.
To set a temporary PIN You may authorize access by visitors or service people with a temporary 4-digit PIN. After a programmed number of hours or number of accesses, this temporary PIN expires and will no longer open the door. It can be used to close the door even after it has expired. To set a temporary PIN: 1. Press the four buttons for your personal entry PIN (not the last temporary PIN), then press and hold the ✽ button. The opener light will blink three times. Release the button.
One Button Close: Opener can be closed by pressing only the ENTER button if the one button close feature has been activated. This feature has been activated at the factory. To activate or deactivate this feature press and hold buttons 1 and 9 for 10 seconds. The keypad will blink twice when the one button close is active. The keypad will blink four times when one button close is deactivated.

1 4A1008 Master link kit 2 41A4813 Chain pulley bracket 3 41A3489 Complete trolley assembly 4 1707LMC One-piece rail - 7' (2.1 m) 1708LMC One-piece rail - 8' (2.4 m) 1710LMC One-piece rail - 10' (3 m) 5 41D3484 Full chain assembly 6 83A11-2 Rail grease
1 41A5273-1 Multi-function door control panel 2 373LMC 3-Button remote control 3 10A20 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A5047 Door bracket w/clevis pin & fastener 6 41A2828 Emergency release rope & handle assembly 7 178B34 Straight door arm section 8 41A4353 Header bracket w clevis pin & fastener 9 41A5034 Safety sensor kit (receiving and sending eyes) with 3' (.9 m) 2-conductor bell wire 10 41A5266-1 Safety sensor brackets (2) 11 41B4494-1 2-Conductor bell wire, white & white/ red 12 178B35 Curved door arm section
LIGHT
NOTICE
CEILING MOUNT ONLY
UP
NOT SHOWN 41A2770-6 Installation hardware bag (includes hardware listed on page 5). 114A3646 Owner’s manual

8 13 14
DN
UP
(Up) Contact Center Limit Contact
KEY PART NO. NO. DESCRIPTION
1 31D380 Sprocket cover 2 41C4220A Gear and sprocket assembly Complete with: Spring washer, thrust washer, retaining ring, bearing plate, roll pins (2), drive gear and worm gear, helical gear w/ retainer and grease 3 41A2817 Drive/worm gear kit w/grease, roll pins (2) 4 41B4245 Line cord 5 41A5484-1 End panel w/all labels 6 4A1344 Light socket 7 108D79 Lens 8 30B532 Capacitor 9 12A373 Capacitor bracket 10 41A3150 Terminal block w/screws 11 41D3058 Universal replacement motor & bracket assembly Complete with: Motor, worm, bracket, bearing assembly, RPM sensor
12 41A5525-1 Cover 13 41A2818 Limit switch drive & retainer 14 41D3452 Limit switch assembly 15 41A2822-1 Interrupter cup assembly 16 41C4398A RPM sensor assembly 17 41AC050-2M Receiver logic board assy. Complete with: Logic board, end panel w/all labels, light socket 18 41C5498 Low voltage wire harness assembly. 41C5497 High voltage wire harness assembly. 19 41D180-1 End panel w/all labels
NOT SHOWN 41A2826 Motor shaft bearing kit 41A2825 Opener assembly hardware kit (includes screws not designated by a number in illustration)

1702LM Outside Quick Release: Required for a garage with NO access door. Enables homeowner to open garage door manually from outside by disengaging trolley.
SECURITY✚® 3-Button Remote Control: Includes visor clip.
373WC
Designer Burled Walnut 3-Button Remote Control with Security✚®:
Extension Brackets: (Optional) For safety sensor installation onto the wall or floor.
Includes visor clip.
373LMC 3-Button Security✚® Remote Control:
Multi-Function Door Control Panel: Provides a Lock Feature which prevents operation of garage door opener from portable remotes and a Light Feature for constant light.
Includes visor clip.
4-Button Security✚® Remote Control:
LOCK
LIGHT
Includes visor clip.
902LMC/ 903LMC 2 & 3 Door Multi-Function Wall Control: Ideal for homes with up to three garage doors. Combine up to three controls into one wall control panel for a neat compact appearance. Enhanced functions include Lock Feature to lock out outside radio signals while you are away from home and turn opener lights on or off from the control panel. Garage Door Monitor: Security for the largest door of your home! Tells you if your garage door is open or closed. Monitors up to 4 garage doors by adding additional sensor modules.
3-Button Mini-Remote Control with Security✚®: With key ring and fastening strip.
377LMC
Wireless Keyless Entry with Security✚®: Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard. Also can add a temporary password for visitors or service persons. This temporary password can be limited to a programmable number of hours or entries.
OPEN
975LMC Laser Park Assist: Laser enables homeowners to precisely park vehicles in the garage.
Garage Door Monitor Sensor: Additional accessory sensor for homes with multiple garage doors.
Remote Light Control: Enables homeowner to turn on a lamp, television or other appliance from their car with their garage door opener remote or from anywhere in their home with an additional LiftMaster Security✚® remote.

HOW TO ORDER
ON CALL
REPAIR PARTS
Selling prices will be furnished on request or parts will be shipped at prevailing prices and you will be billed accordingly.
SPANS AMERICA AND CANADA
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE
FOLLOWING INFORMATION:
INSTALLATION AND SERVICE INFORMATION IS AS NEAR
FREE NUMBER: 1-800-528-9131
ADDRESS ORDERS TO: THE CHAMBERLAIN GROUP, INC.
Technical Support Group 6050 S. Country Club Road Tucson, Arizona 85706
For professional installation, parts and service, contact your local LIFTMASTER/CHAMBERLAIN dealer. Look for him
TOLL FREE NUMBER: 1-800-528-9131
in the Yellow Pages, or call our Service number for a list of
dealers in your area.
LIFETIME MOTOR LIMITED WARRANTY
The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of one year from the date of purchase and that the motor is free from defect in materials and/or workmanship for the lifetime of the product. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-9131, toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of- purchase receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.
THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, AND OF ANY OTHER OBLIGATIONS OR LIABILITY ON SELLER’S PART. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, REPLACEMENT OF BATTERIES AND LIGHT BULBS OR UNITS INSTALLED FOR NON-RESIDENTIAL USE.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.
Some provinces do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from province to province.
© 2008, The Chamberlain Group, Inc. 114A3646 All Rights Reserved
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| otor Circuit Failure. eplace Receiver gic Board. | p.30 |