Manuel d'utilisation / d'entretien du produit UVCVR36 du fabricant CFM
Aller à la page of 16
DO NOT INST ALL THE APPLIANCE IN THIS FIREBOX, UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INST ALLA TION. W ARNING: If the information in this manual is not followed exactly , a fire or explosion may result causing property damage, personal injury or loss of life.
2 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Description The UVSTR36 and UVCVR36 models are ventless fireboxes designed for installation with any ventless gas log set for a see-through application and certified to ANSI Z21.1 1.2 standards.
3 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 General Information Installation Precautions This Majestic Fireplaces firebox and its components have been tested and will operate safely when installed in accordance with this installation manual.
4 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 FP677 Fig. 2 UVCVR36 Series specification and framing dimensions. UVCVR36 Specifications 36" 36" 40 " " .
5 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Minimum Clearances Sidewall Clearances: The clearance from the side of the firebox to any com- bustible wall should not be less than 1 1" . (Fig. 3A) Ceiling Clearances: The ceiling height should not be less than 42" from the top of the fireplace opening.
6 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Installation Installing Outside Air Kit An outside air kit may be installed in all UVSTR/CVR Series fireboxes. If desired, or if local codes man- date the use of an air kit, then an AKU2 is required to complete the installation (from air kit to out-of-doors).
7 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Install Gas Log Heater 1. Connect the shutoff valve, union and any required approved fittings (See NOTE below) between the valve and the gas line. Access to the gas line on the UV Series firebox is made through the left or right side of the firebox.
8 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Finishing See Page 5, Figure 3 for allowable finishing materials and clearances to combustibles. All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround must be completely sealed with a noncombustible ma- terial.
9 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Install Hood A 2" or 4" Hood can be purchased for the UVSTR36 and the UVCVR36. A Hood must be installed if the mantel falls within the dimensions and location shown in Figure 3. Failure to do so may create a fire hazard.
10 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Keep the control compartment, logs and burner area surrounding the logs clean by carefully vacuuming or brushing at least twice a year or as necessary . THE LOGS CAN GET VER Y HOT – HANDLE ONL Y WHEN COOL.
1 1 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 7 1 2 4 5 6 3 960 UVCVR Parts 4/22/98 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
12 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 1 2 3 4 5 FP686 UVSTR Parts 4/22/98 UVSTR V ent Free Firebox Ref. Description UVSTR 1. Brick - Filler 3079148 2. Brick - Side 3079147 3. Brick - Hearth 3087102 4. Screen Assembly (Screens and Rod) 3049121 5.
13 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Outside Air Completes connection from air kit to out-of-doors AKU2 T ermination 2" Hood For heater up to 40,000 BTU's with a mantel .
14 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960.
15 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 BASIC W ARRANTY CFM Corporation (hereinafter referred to collect ively as the Company) warrants that your new V ermont Castings or Majestic Ga.
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté CFM UVCVR36 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du CFM UVCVR36 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation CFM UVCVR36, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le CFM UVCVR36 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le CFM UVCVR36, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du CFM UVCVR36.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le CFM UVCVR36. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei CFM UVCVR36 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.