E fx-1 15ES PLUS f x - 991ES PLUS C User ’ s Guide CASIO Worldwide Education Website http://edu.casio.com CASIO EDUCATIONAL FORUM http://edu.casio.com/forum/.
Contents Important Information ............................................................. 2 Sample Operations .................................................................. 2 Initializing the Calculator .........................................
E-2 Impor tant Information • The displays and illustrations (such as key markings) shown in this User’s Guide are for illustrative purposes only, and may differ somewhat from the actual items they represent. • The contents of this manual are subject to change without notice.
E-3 • Never try to take the calculator apart. • Use a soft, dry cloth to clean the exterior of the calculator . • Whenever discarding the calculator or batteries, be sure to do so in accordance with the laws and regulations in your particular area.
E-4 Reading the Display The display of the calculator shows expressions you input, calculation results, and various indicators. Input expression Indicators Calculation result • If a ' indicator appears on the right side of the calculation result, it means the displayed calculation result continues to the right.
E-5 Disp The display currently shows an intermediate result of a multi-statement calculation. Important: For some type of calculation that takes a long time to execute, the display may show only the above indicators (without any value) while it performs the calculation internally.
E-6 1 MthIO 2 LineIO Specifies the display format. Natural Display (MthIO) causes fractions, irrational numbers, and other expressions to be displayed as they are written on paper. MthIO: Selects MathO or LineO. MathO displays input and calculation results using the same format as they are written on paper.
E-7 c 6 Rdec 1 ON ; 2 OFF Specifies whether or not to display calculation results using recurring decimal form. c 7 Disp 1 Dot ; 2 Comma Specifies whether to display a dot or a comma for the calculation result decimal point. A dot is always displayed during input.
E-8 e while the cursor is at the end of the input calculation will cause it to jump to the beginning, while pressing d while the cursor is at the beginning will cause it to jump to the end. • You can input up to 99 bytes for a calculation. Each numeral, symbol, or function normally uses one byte.
E-9 Important: • Certain types of expressions can cause the height of a calculation formula to be greater than one display line. The maximum allowable height of a calculation formula is two display screens (31 dots × 2). Further input will become impossible if the height of the calculation you are inputting exceeds the allowable limit.
E-10 T o insert a character or function into a calculation: Use d and e to move the cursor to the location where you want to insert the character or function and then input it. Be sure always to use the insert mode if Linear Display is selected. T o clear all of the calculation you are inputting: Press A .
E-11 Note: • You can specify up to 14 decimal places for the recurring decimal period. If you input more than 14 decimal places, the value will be treated as a terminating decimal and not a recurring decimal. • Recurring decimal value input can be performed regardless of the Rdec setting on the setup menu.
E-12 Return to initial display format (Norm 1): f 7 1 = 0.142857 = 0.1428571429 (Norm 1) b 1 ' 7 = Display as recurring decimal: f Decimal value according to Norm 1 setting: f Return to initial display format (fraction): f 1 ÷ 7 = 0.1428571429 (Norm 1) = 0.
E-13 • The data size of value to be displayed as the recurring decimal must be no larger than 99 bytes. Each value and the decimal point require one byte, and each digit of the period requires one byte. The following, for example, would require of total of 8 bytes (4 bytes for the values, 1 byte for the decimal point, 3 bytes for the period): 0.
E-14 T oggling Calculation Results While Natural Display is selected, each press of f will toggle the currently displayed calculation result between its fraction form and decimal form, its ' form and decimal form, or its π form and decimal form.
E-15 1 = 1 2 2 4 − 3 B 4 - 1 ' ( ( ) 3 e 1 c 2 = 1 2 b 4 - 3 ' 1 ' 2 = 1 { 2 Note: • Mixing fractions and decimal values in a calculation while Linear Display is selected will cause the result to be displayed as a decimal value. • Fractions in calculation results are displayed after being reduced to their lowest terms.
E-16 Multi-Statements You can use the colon character (:) to connect two or more expressions and execute them in sequence from left to right when you press = . 3 + 3 : 3 × 3 3 + 3 S 7 (:) 3 * 3 = 6 = 9 Using Engineering Notation A simple key operation transforms a displayed value to engineering notation.
E-17 Answer Memory (Ans) /Previous Answer Memory (PreAns) The last calculation result obtained is stored in Ans (answer) memory. The calculation result obtained prior to the last one is stored in PreAns (previous answer) memory.
E-18 V ariables (A, B, C, D, E, F , X, Y) Your calculator has eight preset variables named A, B, C, D, E, F, X, and Y. You can assign values to variables and also use the variables in calculations.
E-19 Note: • Only the quotient value of a ÷R calculation is stored in Ans memory. • Assigning the result of a remainder division calculation to a variable will assign the quotient value only. Performing the operation 5 a ' (÷R) 2 ! t (STO) ) (X) (which assigns the result of 5÷R2 to X) will assign a value of 2 to X.
E-20 Function Calculations For actual operations using each function, see the “Examples” section following the list below. π π : π is displayed as 3.141592654, but π = 3.14159265358980 is used for internal calculations. e : e is displayed as 2.
E-21 can be specified within the range of –1 × 10 10 a b 1 × 10 10 . See 10 . Note: The following cannot be used in f ( x ): Pol, Rec, ÷R. The following cannot be used in f ( x ), a , or b : ∫ , d / dx , Σ , Π . 9 : Determines the product of f ( x ) over a given range.
E-22 Intg: Determines the largest integer that does not exceed a value. See 21 . Note: Using functions can slow down a calculation, which may delay display of the result. Do not perform any subsequent operation while waiting for the calculation result to appear.
E-23 Examples sin 30°= 0.5 bv s 30 )= 0.5 sin −1 0.5 = 30° bv 1 s (sin −1 ) 0.5 )= 30 sinh 1 = 1.175201194 w b (sinh) 1 )= 1.175201 194 cosh –1 1 = 0 w f (cosh −1 ) 1 )= 0 π /2 radians = 90.
E-24 Σ x = 1 5 ( x + 1) = 20 B 1 & ( 8 ) S ) (X) + 1 e 1 e 5 = 20 b 1 & ( 8 ) S ) (X) + 1 1 ) (,) 1 1 ) (,) 5 )= 20 x =1 5 ( x + 1) = 720 B a & ( 9 ) S ) (X) + 1 e 1 e 5 = 720 b a &am.
E-25 To determine the greatest common divisor of 28 and 35 S * (GCD) 28 1 ) (,) 35 )= 7 To determine the least common multiple of 9 and 15 S / (LCM) 9 1 ) (,) 15 )= 45 To extract the integer part of −3.5 S + (Int) - 3.5 )= −3 To determine the largest integer that does not exceed −3.
E-26 Using a Command to Specify the Calculation Result Format Either of two special commands ( ' r ∠ or ' a + b i ) can be input at the end of a calculation to specify the display format of the calculation results. The command overrides the calculator’s complex number format setting.
E-27 To store A + B i and then determine ' 3 + i , 1 + ' 3 i using polar coordinates ( r ∠ ) v N 2 (CMPLX) S - (A) + S e (B) W ( i ) 1 2 (CMPLX) 3 ( ' r ∠ ) s ! 3 )= 1 = s (.
E-28 Input an initial value for X (Here, input 1): 1 = To exit SOLVE: A Solution screen Note: During the time from when you press 1s (SOLVE) until you exit SOLVE by pressing A , you should use Linear Display input procedures for input.
E-29 Input an initial value for X (Here, input 1): 1 = = 7 == = 13 == Statistical Calculations (ST A T) To start a statistical calculation, perform the key operation N 3 (STAT) to enter the STAT Mode and then use the screen that appears to select the type of calculation you want to perform.
E-30 To select linear regression and input the following data: (170, 66), (173, 68), (179, 75) N 3 (STAT) 2 (A+BX) 170 = 173 = 179 = ce 66 = 68 = 75 = Important: • All data currently input in the St.
E-31 • m , m 1 , m 2 and n are not variables. They are commands of the type that take an argument immediately before them. See “Calculating Estimated Values” for more information. Minimum V alue: minX*, minY, Maximum V alue: maxX*, maxY 1 1 (STAT/DIST) 6 (MinMax) 1 to 2 (When the single-variable statistical calculation is selected.
E-32 A1 1 (STAT/DIST) 5 (Reg) 2 (B) = Results: Linear Regression Correlation Coefficient: 0.923 Logarithmic Regression Correlation Coefficient: 0.998 Logarithmic Regression Formula: y = –3857.
E-33 A 3 1 1 (STAT/DIST) 5 (Distr) 4 ( ' t ) = 1 1 (STAT/DIST) 5 (Distr) 1 (P() G )= Results: Normalized variate ( ' t ): –0.762 P( t ): 0.223 Base- n Calculations (BASE-N) Press N 4 (BASE-N) to enter the BASE-N Mode when you want to perform calculations using decimal, hexadecimal, binary, and/or octal values.
E-34 Octal Positive: 00000000000 x 17777777777 Negative: 20000000000 x 37777777777 Decimal –2147483648 x 2147483647 Hexadecimal Positive: 00000000 x 7FFFFFFF Negative.
E-35 To determine the logical XOR of 1010 2 and 1100 2 (1010 2 xor 1100 2 ) A 1010 1 3 (BASE) 3 (xor) 1100 = 0000000000000110 To determine the logical XNOR of 1111 2 and 101 2 (1111 2 xnor 101 2 ) A 1.
E-36 • A message appears to let you know when there is no solution or when there are infinite solutions. Pressing A or = will return to the Coefficient Editor. Changing the Current Equation T ype Setting Press N 5 (EQN) and then select an equation type from the menu that appears.
E-37 x 3 – 2 x 2 – x + 2 = 0 N 5 (EQN) 4 (aX 3 + bX 2 + cX + d = 0) 1 = - 2 = - 1 = 2 == (X 1 =) –1 c (X 2 =) 2 c (X 3 =) 1 Matrix Calculations (MA TRIX) Use the MATRIX Mode to perform calculations involving matrices of up to 3 rows by 3 columns.
E-38 Matrix Answer Memory Whenever the result of a calculation executed in the MATRIX Mode is a matrix, the MatAns screen will appear with the result. The result also will be assigned to a variable named “MatAns”. The MatAns variable can be used in calculations as described below.
E-39 3 × MatA (Matrix scalar multiplication). A 3 * MatA = Obtain the determinant of MatA (det(MatA)). A1 4 (MATRIX) 7 (det) MatA )= 1 Obtain the transposition of MatC (Trn(MatC)). A1 4 (MATRIX) 8 (Trn) MatC )= Obtain the inverse matrix of MatA (MatA –1 ).
E-40 • Be sure to input the X variable ( S ) (X)) when generating a number table. Any variable other than X is handled as a constant. • If you are using a single function, input a function in the format f ( x ) only. • The following cannot be used in the function: Pol, Rec, ∫ , d/dx , Σ , Π .
E-41 setting, while 20 rows are supported for the “f(x),g(x)” setting. • You can use the number table screen for viewing values only. Table contents cannot be edited. • The number table generation operation causes the contents of variable X to be changed.
E-42 Assigning and Editing V ector V ariable Data Important: The following operations are not supported by the Vector Editor: m , 1m (M–), 1t (STO). Pol, Rec, ÷R, and multi-statements also cannot be input with the Vector Editor. T o assign new data to a vector variable: 1.
E-43 VctA • VctB (Vector dot product) A VctA 1 5 (VECTOR) 7 (Dot) VctB = VctA × VctB (Vector cross product) A VctA * VctB = Obtain the absolute values of VctC. A1w (Abs) VctC )= Determine the angle formed by VctA and VctB to three decimal places (Fix 3).
E-44 • To change a coefficient value you already have input, move the cursor to the appropriate cell, input the new value, and then press = . • Pressing A will clear all of the coefficients to zero. Note: The following operations are not supported by the Coefficient Editor: m , 1m (M–), 1t (STO).
E-45 2 x 3 − 3 x 2 0 B N c 1 (INEQ) 2 (aX 3 + bX 2 + cX + d) 3 (aX 3 + bX 2 + cX + d 0) 2 = - 3 = = 3 x 3 + 3 x 2 – x 0 B N c 1 (INEQ) 2 (aX 3 + bX 2 + cX + d) 1 (aX 3 + bX 2 + cX + d 0) 3 = 3 = - 1 = = eee Note: Solutions are displayed as shown here when Linear Display is selected.
E-46 2. Input 4 ' 9 = 12. 4 ! 9 e 1 6 (VERIFY) 1 (=)12 • You can select the equality symbol or inequality symbol from the menu that appears when you press 1 6 (VERIFY). 3. To verify, press = . You can input the following expressions for verification in the VERIFY Mode.
E-47 VERIFY Mode Calculation Examples To verify log2 log3 log4 l 2 ) 1 6 (VERIFY) 4 ( ) l 3 ) 1 6 (VERIFY) 4 ( ) l 4 )= To verify 0 – ( ) 9 8 9 8 2 B 0 1 6 (VERIFY) 4 ( ) 8 &.
E-48 V ariables that Accept Input The following are distribution calculation variables that accept input values. Normal PD ........................... x , σ , Normal CD ........................... Lower, Upper, σ , Inverse Normal ...........
E-49 35 = Result: 0.1760326634 • Pressing = or A returns to the x input screen. To calculate binomial probability for the sample data {10, 11, 12, 13, 14} when N=15 and p=0.6 N c 3 (DIST) 4 (Binomial PD) Display the List Screen: 1 (List) • To specify data using parameter format, press 2 (Var).
E-50 Ans column of the List Screen when the value input for the corresponding sample data is outside the allowable range. Scientific Constants Your calculator comes with 40 built-in scientific constants that can be used in any mode besides BASE-N.
E-51 23: (e) elementary charge 24: (NA) Avogadro constant 25: (k) Boltzmann constant 26: (Vm) molar volume of ideal gas (273.15K, 100kPa) 27: (R) molar gas constant 28: (C 0 ) speed of light in vacuum.
E-52 The following shows the two-digit numbers for each of the metric conversion commands. 01: in ' cm 02: cm ' in 03: ft ' m 04: m ' ft 05: yd ' m 06: m ' yd 07: mile &a.
E-53 sin –1 x 0 | x | 1 cos –1 x tan –1 x 0 | x | 9.999999999 × 10 99 sinh x 0 | x | 230.2585092 cosh x sinh –1 x 0 | x | 4.999999999 × 10 99 cosh –1 x 1 x 4.999999999 × 10 99 tanh x 0 | x | 9.
E-54 • Precision is basically the same as that described under “Calculation Range and Precision”, above. • x y , x ' y , 3 ' , x !, n P r , n C r type functions require consecutive internal calculation, which can cause accumulation of errors that occur with each calculation.
E-55 Action: • Check the input values, reduce the number of digits, and try again. • When using independent memory or a variable as the argument of a function, make sure that the memory or variable value is within the allowable range for the function.
E-56 Befor e Assuming Malfunction of the Calculator ... Perform the following steps whenever an error occurs during a calculation or when calculation results are not what you expected. If one step does not correct the problem, move on to the next step.
E-57 Specifications Power Requirements: Built-in solar cell; button battery LR44 (GPA76) × 1 Approximate Battery Life: 3 years (based on one hour of operation per day) Operating T emperature: 0°C to 40°C (32°F to 104°F) Dimensions: 11.1 (H) × 80 (W) × 162 (D) mm 3 / 8 ⬙ (H) × 3 1 / 8 ⬙ (W) × 6 3 / 8 ⬙ (D) Approximate Weight: 95 g (3.
CASIO COMPUTER CO ., L TD . 6-2, Hon-machi 1-chome Shibuya-ku, T okyo 151-8543, Japan SA1111-A © 2012 CASIO COMPUTER CO., L TD..
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Casio fx-115ESPlus c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Casio fx-115ESPlus - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Casio fx-115ESPlus, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Casio fx-115ESPlus va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Casio fx-115ESPlus, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Casio fx-115ESPlus.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Casio fx-115ESPlus. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Casio fx-115ESPlus ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.