Manuel d'utilisation / d'entretien du produit EA200 du fabricant Casio
Aller à la page of 55
User’s Guide EA-200 http://world.casio.com/edu_e/ E.
In no event shall CASIO Computer Co., Ltd. be liable to anyone for special, collateral, incidental, or consequential damages in connection with or arising out of the purchase or use of these materials. Moreover , CASIO Computer Co., Ltd. shall not be liable for any claim of any kind whatsoever against the use of these materials by any other party .
20020601 English 0-1 Contents –– English –– Handling Precautions ............................................................................ 0-2 Unpacking .......................................................................................
20020601 English • The EA-200 is made up of precision components. Never try to take it apart. •A void dropping the EA-200 and subjecting it to strong impact. • Do not store the EA-200 or leave it in areas exposed to high temperatures, humidity , low temperatures, or large amounts of dust.
20020601 English User’s Guide EA-200 http://world.casio.com/edu_e/ E Unpacking EA-200 Soft case Data communication cable (SB-62) Te mperature probe Optical probe V oltage probe Four AA-size alkaline.
20020601 English Auto Power Off (APO) To extend battery life, power automatically turns off if you do not perform any operation for about 30 minutes. APO is disabled automatically whenever the EA-200 is standing by for sampling (ready state), or while sampling is in progress.
20020601 English Chapter 1 General Guide P button (rear side)* 2 Key Functions and Indicator Lamps Key Functions To do this: Press this key: Start a sampling operation from the ready state [ST ART/STOP] Stop an ongoing sampling operation [ST ART/STOP] Use Auto Setup (See “Auto Setup” on page 1-5.
20020601 English 1-2 Supported Calculator Models Connection to a supported scientific calculator is essential if you want to get the most out of your EA-200. A connected Graphic Scientific Calculator sends commands that control the EA-200 during transfer of sampled data and other operations.
20020601 English 1-3 Using Commands Basically , the EA-200 is controlled by commands from the connected calculator. This section explains how to send commands from the calculator to the EA-200. To use a command, you store parameters as List data on the calculator , and then use the Send command to send the parameters to the EA-200.
20020601 English 1-4 (2) Send Command 1 to configure channel settings. • V oltage Probe (that is connected to CH1.) {1, 1, 2} → List 1 _ _ _ _ _ The first 1 is the command number , the second 1 is the Send (List 1) _ _ _ _ _ channel number , and the 2 indicates use of the voltage probe.
20020601 English 1-5 Using the Built-in Speaker To output sound recorded by the built-in microphone (1) Send Command 0 to initialize the EA-200 setup. {0} → List 1 _ _ _ _ _ Stores {0} to List 1. 0 is the command number . Send (List 1) _ _ _ _ _ Sending List 1 executes Command 0.
20020601 English 1-6 4. Press the EA-200 [ST ART/ST OP] key to start sampling. • The Sampling lamp flashes as sampling is performed. 5. Press the [ST ART/STOP] key again to stop sampling. 6. Connect the EA-200 to the calculator, and then use the Receive command to transfer the sampled data (see the “Receive Data Command” on page 1-3).
Examples Uniformly Accelerated Motion Period of Pendular Movement Conservation of Momentum Charles’ Law Polarization of Light Natural Frequency and Sound Column of Air Resonance and the V elocit.
20020601 English Activity: Setup Activity: Setup 2-1-1 쐽 Equipment Cart Ram p Stand Protractor Distance Measurement Setup (EA-200, graphic scientific calculator , data communication cable, optional EA-2* 1 ) 쐽 Setting Up u Affix the EA-2 to the arm of the stand.
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-1-2 55555555555555555555555 5555555555555555555555 55555 Other Things T o Do 55555 쐽 Measuring Data u Prepare the Distance Measurement Setup.
20020601 English 쐽 Equipment String with little elasticity W eight Stand Height adjustment blocks (2) Optical Measurement Setup (EA-200, graphic scientific calculator , data communication cable, optical probe) 쐽 Building a Pendulum u Securing the fixed point of the pendulum so it cannot move, assemble the pendulum as shown in the illustration.
20020601 English 쐽 Calculator Operation u Perform the following operation to prepare for light measurement using the optical probe. Using E-CON Using a Calculator Program Find the applicable program in the Program Library (P .2-16-1), input it into your calculator, and then run it.
20020601 English 쐽 Equipment T wo carts of identical mass String Pulley with a bracket to secure it Ve l cro 쑓 500g weight Cushion Distance Measurement Setup (EA-200, graphic scientific calculator , data communication cable, optional EA-2* 1 ) 쐽 Preparing the Carts u Measure the masses of Cart 1 and Cart 2.
20020601 English 쐽 Calculator Operation u Find the applicable program in the Program Library (P .2-16-1), input it into your calculator , and then run it.
20020601 English Activity: Setup Activity: Setup 2-4-1 쐽 Equipment Syringe (with scale markings) Pl astic Contai ner Rubber T ube Rubber Gasket Clip Mixing Stick Warm W ater , Cold Water , Ice T emp.
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-4-2 55555555555555555555555 5555555555555555555555 55555 Other Things T o Do 55555 쐽 Measuring Data u The water temperature is displayed on the calculator .
20020601 English Activity: Setup Activity: Setup 2-5-1 쐽 Equipment Polarizers (2) Thick Paper Wood Penlight Glass Screen Protractor Optical Measurement Setup (EA-200, graphic scientific calculator ,.
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-5-2 55555555555555555555555 5555555555555555555555 55555 Other Things T o Do 55555 쐽 Me.
20020601 English Activity: Setup Activity: Setup 2-6-1 쐽 Equipment Box String Bolts (2) T riangular Wood Blocks (2) Audio Measurement Setup (EA-200, graphic scientific calculator , data communication cable) 쐽 Building a Monochord u Use tape to affix the bolts at either end of the box, and stretch the string taut between them.
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-6-2 쐽 Measuring the Sound Frequency u Position the two wood blocks so there is about 40cm between them, and then lightly pluck the center of the string to produce a sound.
20020601 English Activity: Setup Activity: Setup 2-7-1 쐽 Equipment Glass Resonance T ube (Uniform Inside Diameter , With Scale Markings) Rubber T ube Reservoir Stand Low Frequency Generator (or Tuni.
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-7-2 쐽 Measuring the Resonance Points u Record the sound on the Audio Measurement Setup, display the waveform, and observe the amplitude. u Lower the water level, and find the point of maximum amplitude.
20020601 English Activity: Setup Activity: Setup 2-8-1 쐽 Equipment Piano (Sound Source) Computer (MIDI Sound Source) Audio Measurement Setup (EA-200, graphic scientific calculator , data communication cable) 쐽 Setting Up u T ake care so there is no unwanted noise in the area where you are conducting the activity .
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-8-2 55555555555555555555555 5555555555555555555555 55555 Other Things T o Do 55555 쐽 Analyzing Do-Re-Mi u Record the notes Do, Re, and Mi, and then record the peaks of their frequency distribu- tions.
20020601 English Activity: Setup Activity: Setup 2-9-1 쐽 Equipment Battery (D.C. Power Supply) Resistor Capacitor Coil Switch Vo ltage Measurement Setup (EA-200, graphic scientific calculator , data.
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-9-2 쐽 Measuring Data u Prepare the V oltage Measurement Setup. At the same time you start the measurement operation, move the switch to “ON” to connect the power supply .
20020601 English 쐽 Equipment AC Power Supply (Switched) Resistor Capacitor Coil Vo ltage Measurement Setup (EA-200, graphic scientific calculator , data communication cable, voltage probe (3)) 쐽 Building the RCL Series Circuit u Build a circuit for a 3V , 50Hz power supply .
20020601 English 쐽 Calculator Operation u Perform the following operation to prepare for voltage measurement using the voltage probe. Using E-CON Using a Calculator Program Find the applicable program in the Program Library (P .2-16-3), input it into your calculator , and then run it.
20020601 English Activity: Setup Activity: Setup 2-11-1 쐽 Equipment Stand Heater Reflux Condenser Desiccant Auto Stirrer Beaker Round Bottom Flask (2) Mixing Stick Ice Water Benzene Naphthalene T em.
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-11-2 u As shown in the illustration, force water through the reflux condenser . u For boiling point elevation, turn on the heater and use the T emperature Measurement Setup to measure the temperature.
20020601 English 2-12-1 Activity: Setup Activity: Setup 쐽 Equipment Stand Auto Stirrer Beaker (3) Hydrochloric Acid (Solution) Sodium Hydroxide (Solid) Distilled W ater T emperature Measurement Setu.
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-12-2 쐽 Reaction Path 1 Measurement u T urn on the auto stirrer and start a measurement operation with the calculator . u Little-by-little, add sodium hydroxide ( s ) to the distilled water , and observe how the temperature changes.
20020601 English Activity: Setup Activity: Setup 2-13-1 쐽 Equipment Stand Vo ltaic Battery (Zinc Plate, Copper Plate, Dilute Sulfuric Acid Solution, Cistern) Flashlight Bulb Hydrogen Peroxide Pipett.
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-13-2 u If the variation in voltage becomes small, use the pipette with a bulb to inject a small amount of hydrogen peroxide into the dilute sulfuric acid around the copper plate.
20020601 English Activity: Setup Activity: Setup 2-14-1 쐽 Equipment Solar Cell Panel (Operating V oltage: 5V max.) Magnetic Compass Rain Cover Wood Block Vo ltage Measurement Setup (EA-200, graphic .
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-14-2 55555555555555555555555 5555555555555555555555 5555555555555 Other Things T o Do 5555555555555 쐽 Performing Preliminary Measurements u Display the light intensity (or voltage) measurement result on the calculator .
20020601 English Activity: Setup Activity: Setup 2-15-1 쐽 Equipment 500ml Clear Plastic Bottles (3) Dry Earth (or Sand) Seawater (or W ater) Styrofoam Boards Rain Cover Te mperature Measurement Setu.
20020601 English Activity: Operating the Equipment Activity: Operating the Equipment Measurement Measurement 2-15-2 쐽 Measuring Data u Prepare the T emperature Measurement Setup and start temperature measurement. u Cover the system with the rain cover .
20020601 English 2-16-1 Pr ogram Librar y Y ou can download the programs used in the activities at the CASIO W ebsite: http://world.casio.com/edu_e/ Uniformly Accelerated Motion Conservation of Momentum Period of Pendular Movement Charles’ Law * This program cannot be run on an fx-7400 Series calculator .
20020601 English 2-16-2 Polarization of Light Natural Ferquency and Sound Column of Air Resonance and the Velocity of Sound Construction of the Musical Scale Light Multi Meter * This program cannot be run on an fx-7400 Series calculator .
20020601 English 2-16-3 Direct Current and T ransient Phenomena AC Circuit Dilute Solution Properties Exothermic Reaction.
20020601 English 2-16-4 Electromotive Force of a Battery Sunlight and Solar Cells T opographic Conditions and Climate *R un the following program after sampling is complete.
20020601 English Channel Operation Post-Processing FFT Samples 0 Clear all channels ––– ––– ––– *1 Channel 1 0 Clear the selected channel.
20020601 English Command 3 - Sample and T rigger Setup Sample Interval Number of Samples Record T ime 0.00002 Number of seconds 1 to Number of samples 0 Off to 16000 120000 *1 Absolute time recording (*0.
20020601 English Command 4 – Conversion Equation Setup { 4, Equation Number, Equation T ype, Number Format, Constants } Equation Number Equation T ype Number Format Constants * 0 Clear All equations. * 0 Clear equation selected by the equation number parameter .
20020601 English Command APO Time(sec) 0 or 2 Abort Sampling ( *0) 3T u r ns sound off ––– 4T u r ns sound on 10 APO * 0 1800 (Auto Power Off) 1 10 23 6 0 Wa rmup Time (sec) 0.
20020601 English α -2-1 Appendix B Specifications Model: ............................... CASIO EA-200 Power Supply: ................... Four AA-size alkaline batteries (LR6 (AM3)) or AC adaptor (AD-A60024) Power Consumption: ......... 1.5W Battery Life: .
20020601 English MEMO.
20020601 English MEMO.
SA0208-000102B Printed in Japan A342984-008V01 Printed on recycled paper. CASIO COMPUTER CO., LTD. 6-2, Hon-machi 1-chome Shibuya-ku, Tokyo 151-8543, Japan.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Casio EA200 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Casio EA200 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Casio EA200, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Casio EA200 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Casio EA200, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Casio EA200.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Casio EA200. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Casio EA200 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.