Manuel d'utilisation / d'entretien du produit 50AH024-096 du fabricant Carrier
Aller à la page of 20
Manufacturer reserves the right to disco ntinue, or change at any time, specifications or de signs without notice and without inc urring obligations. Catalog No . 04-53500057-0 1 Printed in U. S.A. F orm 50AH-14SI Pg 1 5-10 Replaces: 50AH-12SI Installation, Star t-Up , and Ser vice Instructions CONTENTS SAFETY CONSIDERA T IONS .
2 Evaporator Confi g uration Factory-In s talled Option s 50AH AC 04 8 5 – – – – 2 1 XX 50AH – Horizont a l, Indoor S ingle-P a ck a ge Cooling Unit Packa g in g 1 – Dome s tic 2 – Expor.
3 DET AIL A CLEARANCE HOLE FOR 3 /8" HANGING ROD TYP 8 PL S AIR IN COIL ACCE SS FRONT TOP RIGHT REAR LEFT RETURN AIR S UPPL Y AIR AIR OUT MOT OR ACCE SS ELECT BO X ACCE SS BLOWER ACCE SS EV AP S .
4 64 1/2 6 1/ 8 1 83 /4 1 3 /4 16 1/ 8 1 1/2 3 1 3 /16 1 15/16 44 1/ 8 3 7/ 8 38 1/ 8 6 1/16 24 3 /4 38 1/2 5 15/16 3 1/4 3 1/4 5 7/ 8 1 3 5/ 8 9 5/16 12 3 / 8 6 7/16 2 1/4 5 7/ 8 12 0 lb s . Fig. 3 — Unit Dimensions — 50AH024-060 Units wi th F actory-Instal led Air -Side Economizer a50-8548 NO TES: 1.
5 DET AIL A CLEARANCE HOLE FOR 3 /8" HANGING ROD TYP 8 PL S DET AIL "A" AIR IN MOT OR ACC ELECT BOX ACCE SS COIL ACCE SS COMPRE SS OR ACCE SS FIL TER ACCE SS CONDEN S A TE DRAIN 7/8&quo.
6 1 3 7/16 16 1/16 6 7/16 1 8 3 /4 6 5/ 8 70 1/2 3 1/4 2 1/4 5 7/ 8 22 1/ 8 21 7/16 1 8 15/16 10 7/ 8 3 1/4 5 15/16 1 1/2 72 1/2 1 15/16 61 1/ 8 3 7/ 8 4 3 1/ 8 6 1/16 42 1/2 29 3 /4 12 NO TES: 1. Dimensions are in inches. 2. Economizer weight is 200 l b s.
7 Table 1 — Physical Data LEGEND * Shipping weigh ts include b ase unit plus packag ing. †If componen ts are to b e split, addi tional refrigera nt will b e needed.
8 Table 1 — Ph ysical Data (cont) LEGEND * Shipping weigh ts include b ase unit plus packag ing. †If componen ts are to b e split, addi tional refrigera nt will b e needed.
9 Condensing section must be located in same plane as, or above, evaporator section to main tain the liquid refrigerant seal at the expansion device. This permits expansion device to feed liquid refrigerant to evaporator coil properly . T o split sections (some of the following steps may be eliminated depending on particular application): 1.
10 of the tubing. Use a 1 / 4 -in. hole to mount the valve. Clean and debur the tubing before doing any brazing to ensure that no chips or debris are left in the refrigerant circuit. Remove the Schrader valve cap and core before doing any brazing. 5. After brazing the tubing to the self-sealing coupling halves, evacuate each line to 500 microns.
11 Table 2B — Electrica l Data — Upgrade 1 Evapora tor Motor with Standar d Condenser Motor Table 2C — Electrica l Data — Upgrade 2 Evapora tor Motor with Standar d Condenser Motor LEGEND UNIT.
12 Table 2D — Electrical Data — Upgra de 3 Evaporator Motor with Sta ndard Condenser Motor Table 2E — Electric al Data — Standard Evaporator Moto r with Upgrade 1 Condenser Motor LEGEND UNIT 5.
13 Table 2F — Elect rical Data — Upg rade 1 Eva porator Motor with Upgr ade 1 Condenser Motor Table 2G — Electric al Data — Upgrade 2 Evapo rator Motor with Upgrade 1 Condenser Motor LEGEND UN.
14 Table 2H — Electrical Data — Upg rade 3 Ev aporator Mo tor with Upg rade 1 Con denser Moto r Table 2I — Electrica l Data — Standard Evapo rator Motor with Upgrade 2 Condenser Motor LEGEND U.
15 Table 2J — Electrical Data — Upgrade 1 Eva porator Motor with Upgrade 2 Condense r Motor Table 2K — Electrical Data — Upg rade 2 Evap orator Mot or with Upgr ade 2 Conde nser Motor LEGEND U.
16 Table 2L — Elect rical Data — Upgrad e 3 Evaporator Moto r with Upgrade 2 Cond enser Motor LEGEND Table 3 — Evaporator-Fan Performa nce LEGEND NO TES: 1. Refer to T a b le 1 f or ev aporator f an motor and dr ive inf ormation. 2. Upgrade 1 Static Motor is required for boldface valu es.
17 Table 4 — Co ndenser-Fan Performance LEGEND NO TES: 1. Refer to T a b le 1 f or condenser fan motor and drive inf or mation. 2. Upgrade 1 Static Motor is required for boldface valu es.
18 Blower Belt Adjustment — Inspect blower belt for wear , proper belt tension, and pulley alignment as conditions require or at the beginning of each heating and air conditioning season. Make sure that fan shafts and motor shafts are parallel and level.
.
Manufacturer reserves the right to disco ntinue, or change at any time, specificatio ns or designs without notice and without inc urring obligations. Catalog No .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Carrier 50AH024-096 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Carrier 50AH024-096 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Carrier 50AH024-096, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Carrier 50AH024-096 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Carrier 50AH024-096, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Carrier 50AH024-096.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Carrier 50AH024-096. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Carrier 50AH024-096 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.