Copy right 20 02 Carrie r Cor poration Form 50AH-6PD Single Pac kage Coolin g Units F eatur ing: • compact des ign • fle xibi lity • easy maint enance • hig h quali ty and reli abilit y • qu.
2 locatio n is ideal for th e mainten ance technicia n, and five acce ss pane ls, easi ly removed, provide quick a nd convenient acces s to all co mponents wh en needed.
3 LEGEND *Shipping weights include base unit plus packaging. †If components are to be split, additional refr igerant will be needed. **T wo-speed motor.
4 Thermostat and subb ase — Attractive wall-mounted 24-v accesso ry provide s precise temp erature co ntrol. Automatic a nd Manual changeover mod els availabl e. A thermostat subbase is av ailable that works with Cycle- LOC™ circuitry. If a safety device trips, compressor locks out and su bbase war ning ligh t (LK OUT) al erts occupa nt.
5 Base unit dimensions DIME NSIONS (f t-in .) UNIT 50AH ABCD E 024 2-5 2-1 5 / 8 1- 5 3 / 4 1-2 1-1 036 2-4 3 / 4 2-2 1- 5 3 / 4 1-2 1-1 048 2-5 2-3 1-11 5 / 8 1-8 7 / 8 1-7 7 / 8 060 2-4 3 / 4 2-2 3 .
6 I De ter m ine co oling req uir eme nts at desi gn conditions. Given: Gross Cooling Capacity Required (TC) . . . . . . . . . . . . . . . . . . 39,000 Btuh Sensible Heat Capacity (SHC) . . . . . . 30,500 Btuh T emperature of Air Entering Condenser . .
7 GROSS COOLING CAP ACITIES (cont) LEGEN D NO TES: 1. P e rformance b ased on n ominal con denser airflow l isted in physical dat a table on page 3 . 2. SHC is based on 80 F db temp erature of air ent ering th e coil. Bel o w 80 F db , sub tract (co rr f actor x c fm) from SH C.
8 BEL T DRI VE EV AP ORA T OR F AN PER FORMANC E (Special Order Only, Pricing and or dering on related price pa ges.) LEGEND NO T E: Pulley setti ng must be adjusted to limit cfm to 450 c fm/ton maximum. Unit operation be yond that limit may result in blow-off and condensate problems.
9 ELECTRIC HEA TER ST A TIC PRESSURE DROP (in. wg) NO T E: Abov e electr ic heaters are not UL (Underwriters’ Laboratories) or CSA (Canadian Standards Association) listed f or use with optional high-static e vapor at or-fan motor (048, 060 units only).
10 ELECTR IC HEA TER DA T A LEGEND *May be field conv er ted t o single-phase units, see electric heat inst allation instructions. NO T E: Separate pow er source is required for all heaters. Control from base unit 50AH (24 v). ELECT RIC HE A T ER UNIT 88EN USED WITH UNIT 50AH V- P H (60 Hz) CAP .
11 T ypical w iring schematic 50AH048,060 — 230-1- 60 UNITS LEGEND AHA — Adjustable Heat Anticipator C— Contactor Compressor CB — Circuit Breaker CC — Cooling Compensator E Q UIP GND — Equ.
12 T ypical w iring schematic (c ont) 50AH036,048,060 — 208/2 30- 3-60 UNITS LEGEND AHA — Ad justab le Hea t Anticipator C— Contactor Compres sor CB — Circuit Breaker CC — Cooling Compensato.
13 Application d ata OUTDOOR-AIR TEMPE R A TURE OPERA TING LIMITS (F) Field splitting inst ructions — If componen ts are spli t, maximum length of refrigerant tubing to be used is 50 ft, assumi ng componen ts are installed in same horizo ntal plane.
14 Indoor P a c k aged Unit HV AC Guide S pecific ations — Se ction 15 787 Size Range: 2 to 5 T ons, Nomina l Carrier Mode l Number: 50AH Part 1 — General 1.01 SYSTEM DESCRIPTION Indoor mo unted, electricall y controll ed packaged horizontal cooling unit utilizing a hermetic type scroll compressor .
15 I. O perating char acteristics: 1. Unit shall operate using refrigerant R-22. 2. Unit sha ll be desi gne d for indo or sus pended horiz onta l moun ting an d ope rati on. J. Elec trical Requirements Unit shall ha ve single point power connection to leads in ter minal box.
Manufa cturer reser ves the right to disconti nue, or change at any time, specificat ions or designs wi thout noti ce and without incurrin g obligations.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Carrier 50AH c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Carrier 50AH - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Carrier 50AH, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Carrier 50AH va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Carrier 50AH, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Carrier 50AH.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Carrier 50AH. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Carrier 50AH ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.