Manuel d'utilisation / d'entretien du produit MONO CLASS D du fabricant Cadence
Aller à la page of 16
MONO CLASS D AMPLIFIERS.
INTRODUCTION 2 Thank you for purchasing a Cadence T ype RS amplifier . Over the past years, the technology used to create audio amplifiers has grown by leaps and bounds. W e have thousands of satisfied customers still using our first generation Ultra Drive amplifiers which are almost 10 years old.
FEA TURES 3 GOLD PLA TED TERMINALS: BASS DRIVE EQUALIZA TION CIRCUITRY : “ADR”: - ACTIVE DYNAMIC REGULA TION CLASS D AUDIO ST AGE PERFORMANCE POWER AND PROTECTION CIRCUITR Y : STIFFENING CAP ACITO.
FEA TURES 4 “ARV A” - AUTOMA TIC RAIL VOL T AGE ADJUSTMENT CIRCUITR Y : AMPLIFIER MODE SWITCH BA TTERY VOL T AGE: INDUCTION AND TUNNEL F AN COOLING: PROTECTION CIRCUITR Y : Cadence RS amplifiers feature "ARV A" circuitry in their power supply .
INST ALLA TION BASICS 5 INST ALLA TION BASICS: REMOTE TURN ON CONECTION: STIFFENING CAP ACITOR DIRECT CONNECTION: USING THE RS AMPLIFIERS IN CONJUNCTION WITH A MUL TI- CHANNEL AMPLIFIER: POWER/GROUND WIRING: Before you begin with your installation disconnect the NEGA TIVE (-) terminal from your car's battery .
MOUNTING 6 MOUNTING THE RS AMPLIFIERS: 1 A B A 2 3 Choose a convenient mounting location with unobstructed airflow . 1 - Mount and fasten amplifier bracket A onto the mounting surface, with two screws as shown. 2 - Slide the amplifier so that hook B engages with bracket A.
Remote turn on Remote turn on Mode switch Line level inputs from head unit S tereo RCA cable from RS LINE OUT to highs amp LINE IN CPR Remote Control Woofer 1 ohm minimum High frequency speakers Groun.
USING THE CPR REMOTE CONTROL WITH THE RS AMPLIFIERS 8 CPR (COMPETITION PODIUM REMOTE) BASICS LEVEL CONTROL: BURST BUTTON: DIGIT AL BA TTERY VOL T AGE MONITOR: POWER BARGRAPH: INST ALLA TION: The optional CPR remote control can be used for street or SPL competitions alike.
ADJUSTING THE SYSTEM 9 SETTING THE TOP P ANEL CONTROLS ADJUSTING THE SYSTEM AUDIO PREAMP INPUT AUDIO PREAMP OUTPUT USING THE BUIL T-IN LOW P ASS ELECTRONIC CROSSOVER SUBSONIC FIL TERING . PHASE SHIFT CONTROL AMPLIFIER MODE SWITCH The RS amplifiers feature RCA preamp inputs.
MASTER/SLA VE CONNECTION DIAGRAM MONO BRIDGING 2 AMPLIFIERS INTO 1 WOOFER 10 Mode switch Mode switch 2 ohm minimum AMPLIFIER MODE SWITCH, INPUTS AND REMOTE CONTROL Set the AMPLIFIER MODE switches as shown Connect the source to the master amplifier inputs, and an optional CPR remote control to the master , as shown.
MONO BRIDGING MUL TIPLE P AIRS OF AMPLIFIERS 2 OR MORE AMPLIFIERS WITH SEP ARA TE SPEAKERS IMPORT ANT : Note the reverse speaker phase on 2nd amplifier IMPORT ANT : Reverse the speaker phase on every .
BASIC SPEAKER WIRING DIAGRAMS FOR V ARIOUS LOADS 12 4 OHM 8 OHM 2 OHM 4 OHM 1 OHM TO AMPLIFIER 2 OHM TO AMPLIFIER 4 OHM TO AMPLIFIER 8 OHM TO AMPLIFIER 1 OHM TO AMPLIFIER 2 OHM TO AMPLIFIER + + + + + .
ADV ANCED SPEAKER WIRING DIAGRAMS FOR V ARIOUS LOADS 13 P ARALLEL: DUAL VOICE COIL SPEAKERS 3 X DUAL VC 8 OHM SPEAKERS WITH P ARALLEL VOICE COILS, IN P ARALLEL 2 X DUAL VC 4 OHM SPEAKERS WITH P ARALLE.
TROUBLESHOOTING 14 GENERAL TOOLS NEEDED NO SOUND By utilizing this process of elimination you can determine where the cause of the problem is. If the amplifier goes in to diagnostic with nothing connected to it, and you are sure of proper power and ground, please contact our service dep artment for further help ay 732 370 5400.
SPECIFICA TIONS 15 Due to constant product improvements, these specifications are subject to change without notice. High current rated powers are at amplifier minimum distortion and are for competition purposes. Not responsible for typographical errors.
MONO CLASS D AMPLIFIERS.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Cadence MONO CLASS D c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Cadence MONO CLASS D - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Cadence MONO CLASS D, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Cadence MONO CLASS D va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Cadence MONO CLASS D, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Cadence MONO CLASS D.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Cadence MONO CLASS D. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Cadence MONO CLASS D ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.