NOTE: Read the entire instruction in manual applicable to specific unit before starting the installation. This symbol → indicates a change since the last issue.
I. INSPECT PACKAGE AND CHECK EQUIPMENT Inspect contents of packaged humidifier. File claim with shipping company prior to installation if shipment is damaged or incom- plete. The package should contain: 1. Humidifier and media assembly 2. Humidistat 3.
VI. INSTALL DRAIN LINE 1. Use 1/2- or 5/8-in. vinyl tubing (field supplied) to connect drain on bottom of humidifier housing to an open drain. 2. Use supplied worm clamp to hold drain tubing in position over drain fitting outlet. CAUTION: Unit may leak if drain tubing is misapplied.
II. SELECT LOCATION (SEE FIG. 5.) Humidifier must be installed on supply plenum only. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal.
INSTALLATION OF HUMBBSFP1016-A-- FAN POWERED HUMIDIFIER Bryant’s HUMBBSFP1016-A-- fan powered humidifier can only be installed on the supply plenum of a forced-air system. This unit requires an external 115-vac (fused) plug-in receptacle near the equipment for proper operation.
IV. MOUNT THE HUMIDIFIER 1. Attach foam tape to back of mounting flange (exclude the off-set edge). 2. Hook off-set edge over opening cut in plenum. 3. Place humidifier in plenum aligning screw holes with flange. 4. Align, level, and tighten all screws for air tight seal.
INSTALLATION OF HUMBBSBP2017-A-- BYPASS HUMIDIFIER Bryant’s HUMBBSBP2017-A-- bypass humidifier can be installed on either the supply or return plenum of a forced air system. This unit requires an external bypass duct between the supply- and return-air ductwork.
5. Attach transfer tube to solenoid valve and insert free end into inlet fitting on top of unit housing. 6. Attach bridge rectifier to solenoid valve. 7. Insert sheet metal screws into lower holes in plenum, pre-drilled using template. 8. Tighten screws until heads protrude approximately 3/16-in.
II. SELECT LOCATION (SEE FIG. 14.) Humidifier may be installed on either supply or return plenum. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal.
VIII. INSTALL HUMIDISTAT AND COMPLETE WIRING 1. Mount humidistat on inside wall or return-air duct in accordance with section INSTALLATION OF HUMIDIS- TAT on page 10. NOTE: Wiring must comply with national electrical code and any local codes or ordinances that may apply.
II. DUCT MOUNTING (LOW VOLTAGE) 1. Locate humidistat at least 8 in. upstream of humidifier in return-air duct. If mounting near elbow area, keep device 6 in.
V. OPERATION When relative humidity falls to humidistat set point, the humidistat switch makes contact and starts humidifier. In some central unit humidifier systems, furnace fan must be operating before humidi- fier will start. An increase in relative humidity above set point will stop humidifier.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bryant HUM-56-1 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bryant HUM-56-1 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bryant HUM-56-1, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bryant HUM-56-1 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bryant HUM-56-1, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bryant HUM-56-1.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bryant HUM-56-1. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bryant HUM-56-1 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.