Manuel d'utilisation / d'entretien du produit GT-PG (50YE) du fabricant Bryant
Aller à la page of 48
GT -PG (50YE) P ackaged Ser ies SINGLE-ST A GE HORIZONT AL, VER TIC AL, AND DO WNFLO W PURON ® SYSTEMS SIZES 018 - 070 [5.3 - 21.1 kW] Revised June 10, 2013.
GT -PG 2 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. T ab le of Contents What’ s New With The GT -PG? ..................................................... 3 GT -PG Design Features .............................................................
Br y ant Geother mal Heat Pump Systems GT -PG 3 Residential Products T echnical Guide Copeland – turned theor y into pr actical reality , using sophisticated, computer -assisted design and manufacturing methods to achieve the critical toler ances required.
GT -PG 4 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. The GT -PG Ser ies has abundant features and industr y leading ef fi ciency . Application Flexibility • Eight Capacities 018, 024, 030, 036, 042, 048, 060 and 070. • Extended range oper ation (20-120°F EWT) and fl ow r ates as low as 1.
Br y ant Geother mal Heat Pump Systems GT -PG 5 Residential Products T echnical Guide Options & Accessor ies • Optional hot water generator with inter nally mounted pump. • Optional cupro-nickel coaxial heat exchanger . • Electronic thermostat.
GT -PG 6 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. Unit Model Key 5 0 J 0 2 4 B C 3 1 1 4 5 6 7 8 91 0 1 1 1 2 Prefix Series 018, 024, 030, 036, 042, 048, 060, 070 Unit Size Air Flow Configur.
Br y ant Geother mal Heat Pump Systems GT -PG 7 Residential Products T echnical Guide About AHRI/ISO/ASHRAE 13256-1 About AHRI/ISO/ASHRAE 13256-1 AHRI/ASHRAE/ISO 13256-1 (Air -Conditioning and Refrige.
GT -PG 8 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. AHRI/ISO/ASHRAE/ANSI 13256-1 P erfor mance ASHRAE/AHRI/ISO 13256-1. English (I-P) Units ASHRAE/AHRI/ISO 13256-1.
Br y ant Geother mal Heat Pump Systems GT -PG 9 Residential Products T echnical Guide Ref er ence Calculations & Legend L WT = EWT - HE GPM x 500 LA T = EA T + HC CFM x1.
GT -PG 10 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. Air Flo w Cor rection Factor s PSC Fan Motor Air fl ow Cooling Heating % of Rated T otal Capacity Sensible Capacity S/T Power Heat of Rejection Heating Capacity Power Heat of Extraction 68.
Br y ant Geother mal Heat Pump Systems GT -PG 11 Residential Products T echnical Guide Enter ing Air Cor rection Factor s Heating Entering Air DB°F Heating Capacity Power Heat of Extraction 45 1.0514 0.7749 1.1240 50 1.0426 0.81 13 1.1032 55 1.0329 0.
GT -PG 12 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. N/A N/A 1575 47.0 5.12 30.6 98 2.69 5.3 N/A N/A 2100 48.3 4.68 32.5 91 3.02 4.5 22.3 - 1575 50.7 5.21 33.9 100 2.85 6.2 22.5 - 2100 52.1 4.77 36.0 93 3.20 5.3 23.6 - 1575 52.8 5.26 35.8 101 2.
Br y ant Geother mal Heat Pump Systems GT -PG 13 Residential Products T echnical Guide P erfor mance Data — GT -PG Model 018 - PSC Blow er 600 CFM Nominal (Rated) Air fl ow Cooling, 600 CFM Nominal.
GT -PG 14 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. P erfor mance Data — GT -PG Model 018 - ECM Blow er Operation not recommended Operation not recommended 750 CFM Nominal (Rated) Air fl o.
Br y ant Geother mal Heat Pump Systems GT -PG 15 Residential Products T echnical Guide P erfor mance Data — GT -PG Model 024 - PSC Blow er 850 CFM Nominal (Rated) Air fl ow Cooling, 850 CFM Nominal.
GT -PG 16 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. P erfor mance Data — GT -PG Model 024 - ECM Blow er 850 CFM Nominal (Rated) Air fl ow Cooling, 950 CFM Nominal (Rated) Air fl ow Heatin.
Br y ant Geother mal Heat Pump Systems GT -PG 17 Residential Products T echnical Guide P erfor mance Data — GT -PG Model 030 - PSC Blow er 950 CFM Nominal (Rated) Air fl ow Cooling,950 CFM Nominal .
GT -PG 18 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. P erfor mance Data — GT -PG Model 030 - ECM Blow er 1,000 CFM Nominal (Rated) Air fl ow Cooling, 1,100 CFM Nominal (Rated) Air fl ow He.
Br y ant Geother mal Heat Pump Systems GT -PG 19 Residential Products T echnical Guide P erfor mance Data — GT -PG Model 036 - PSC Blow er 1,250 CFM Nominal (Rated) Air fl ow Cooling, 1,250 CFM Nom.
GT -PG 20 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. P erfor mance Data — GT -PG Model 036 - ECM Blow er 1,250 CFM Nominal (Rated) Air fl ow Cooling, 1,250 CFM Nominal (Rated) Air fl ow He.
Br y ant Geother mal Heat Pump Systems GT -PG 21 Residential Products T echnical Guide P erfor mance Data — GT -PG Model 042 - PSC Blow er 1,400 CFM Nominal (Rated) Air fl ow Cooling, 1,400 CFM Nom.
GT -PG 22 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. P erfor mance Data — GT -PG Model 042 - ECM Blow er 1,400 CFM Nominal (Rated) Air fl ow Cooling, 1,400 CFM Nominal (Rated) Air fl ow He.
Br y ant Geother mal Heat Pump Systems GT -PG 23 Residential Products T echnical Guide P erfor mance Data — GT -PG Model 048 - PSC Blow er 1,600 CFM Nominal (Rated) Air fl ow Cooling, 1,600 CFM Nom.
GT -PG 24 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. P erfor mance Data — GT -PG Model 048 - ECM Blow er 1,550 CFM Nominal (Rated) Air fl ow Cooling, 1,650 CFM Nominal (Rated) Air fl ow He.
Br y ant Geother mal Heat Pump Systems GT -PG 25 Residential Products T echnical Guide P erfor mance Data — GT -PG Model 060 - PSC Blow er 1,950 CFM Nominal (Rated) Air fl ow Cooling, 1,950 CFM Nom.
GT -PG 26 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. P erfor mance Data — GT -PG Model 060 - ECM Blow er 1,825 CFM Nominal (Rated) Air fl ow Cooling, 2,050 CFM Nominal (Rated) Air fl ow He.
Br y ant Geother mal Heat Pump Systems GT -PG 27 Residential Products T echnical Guide P erfor mance Data — GT -PG Model 070 - ECM Blow er 1,950 CFM Nominal (Rated) Air fl ow Cooling, 2,100 CFM Nom.
GT -PG 28 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. Ph ysical Data Model 018 024 030 036 042 048 060 070 Compressor (1 Each) Copeland Scroll Factory Charge HFC-410a, oz [kg] 50 [1.13] 56 [1.59] 58 [1.64] 70 [1.96] 80 [2.27] 80 [2.27] 136 [3.86] 144 [4.
Br y ant Geother mal Heat Pump Systems GT -PG 29 Residential Products T echnical Guide Dimensions — V er tical Up fl o w GT -PG (50YE) Ser ies Condensate is 3/4” PVC female glue socket and is switchable from fr ont to side. Unit shipped with deluxe duct collar/ fi lter rack extending fr om unit 3” [7.
GT -PG 30 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. Dimensions — V er tical Up fl o w GT -PG (50YE) Ser ies V ertical Up fl ow Model Discharge Connection Duct Flange Installed (+/- 0.20 in, +/- 5.1mm) Return Connection Standard Deluxe Filter Rack (+/- 0.
Br y ant Geother mal Heat Pump Systems GT -PG 31 Residential Products T echnical Guide Dimensions — V er tical Do wn fl ow GT -PG (50YE) Ser ies Condensate is 3/4” PVC female glue socket and is switchable from fr ont to side. Unit shipped with deluxe duct collar/ fi lter rack extending fr om unit 3” [7.
GT -PG 32 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. Dimensions — V er tical Do wn fl ow GT -PG (50YE) Ser ies V ertical Down fl ow Model Discharge Connection Duct Flange Installed (+/- 0.20 in, +/- 5.1mm) Return Connection Standard Deluxe Filter Rack (+/- 0.
Br y ant Geother mal Heat Pump Systems GT -PG 33 Residential Products T echnical Guide Dimensions — Hor izontal GT -PG (50YE) Ser ies Condensate is 3/4” FPT . Unit shipped with deluxe duct collar/ fi lter rack extending fr om unit 3” [7.6cm] and is suitable for duct connection.
GT -PG 34 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. Dimensions — Hor izontal GT -PG (50YE) Ser ies Horizontal Model 1 Discharge Connection Duct Flange Installed (+/- 0.20 in, +/- 5.1mm) Return Connection Standard Deluxe Filter Rack (+/- 0.20 in, +/- 5.
Br y ant Geother mal Heat Pump Systems GT -PG 35 Residential Products T echnical Guide Electr ical Data Rated V oltage of 208-230/60/1 Min/Max V oltage of 197/254 HACR circuit br eaker in USA only All.
GT -PG 36 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. GT -PG ECM Electr ical Wir ing Diagr am - 96B0005N37.
Br y ant Geother mal Heat Pump Systems GT -PG 37 Residential Products T echnical Guide GT -PG PSC Electr ical Wir ing Diagr am - 96B0005N36.
GT -PG 38 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. GT -PG ECM & Whole House Dehumidi fi cation Electr ical Wir ing Diagr am - 96B0216N33.
Br y ant Geother mal Heat Pump Systems GT -PG 39 Residential Products T echnical Guide GT -PG ECM Control Features The EC M f a n i s co n tr o l l e d by an i nte r fa c e b oa r d t h a t conv er ts thermostat inputs and fi eld selectable CF M set ti n g s to sig n a ls u s ed by t h e ECM m o to r c o n t r o ll e r .
GT -PG 40 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. GT -PG ECM Control Features ECM Board T ap Settings Y GGGGR W O Y2 Y1 G R C Y2 Y1 G O W C R DH AL1 A A AL1 SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 .
Br y ant Geother mal Heat Pump Systems GT -PG 41 Residential Products T echnical Guide Air fl ow in CFM with wet coil and clean air fi lter ECM Blo wer P erfor mance Data Residential Units Only Model Max ESP (in.
GT -PG 42 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. PSC Blo wer P erfor mance Data Air fl ow in CFM with wet coil and clean air fi lter Model Fan Speed Rated Air fl ow Min CFM Air fl ow (cfm) at External Static Pressure (in. wg) 0.00 0.05 0.
Br y ant Geother mal Heat Pump Systems GT -PG 43 Residential Products T echnical Guide Auxiliar y Heat Electr ical Data Auxiliar y Electr ic Heat Auxiliar y Heat Ratings Auxiliary Electric Heat Model GT -PE, GT -PX Packaged Models kW Rating Btuh Rating Minimum CFM Required 018 024- 030 036- 038 042- 072 230V 208V 230V 208V AGM4A 3.
GT -PG 44 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. The water -to-re frig er ant heat exchanger and refr iger ant suction lines shall be insulated to prevent condensation at lo w liquid tem per a tures. Fan Motor a nd B lower The fan shall be a direct drive centr ifugal type with a dynamically balanced wheel.
Br y ant Geother mal Heat Pump Systems GT -PG 45 Residential Products T echnical Guide W arr anty Infor mation The 2010 standard warr anty applies to units ordered on or after July 1, 2010. See Br yant’ s 2010 Limited Express Residential Warranty Cer ti fi cate C A234 for speci fi c co verage and limitation.
GT -PG 46 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. Notes.
Br y ant Geother mal Heat Pump Systems GT -PG 47 Residential Products T echnical Guide Notes.
GT -PG 48 GT -PG (50YE) Ser ies Br yant: Whatever it T akes. Date Page # Description 10 June, 13 38 Updated Unit Wiring Diagram 8 May , 13 All Pages Re-numbered 4 Jan., 12 V arious Deleted references to 070 Model with PSC 28 Sept., 10 154 ECM Electrical Data Updated 28 Sept.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bryant GT-PG (50YE) c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bryant GT-PG (50YE) - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bryant GT-PG (50YE), vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bryant GT-PG (50YE) va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bryant GT-PG (50YE), mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bryant GT-PG (50YE).
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bryant GT-PG (50YE). Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bryant GT-PG (50YE) ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.