Manuel d'utilisation / d'entretien du produit 350MAV du fabricant Bryant
Aller à la page of 16
WARNING: ELECTRICAL SHOCK, FIRE, OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in dangerous operation, serious injury, death, or property damage. Improper servicing could result in dangerous operation, serious indury, death, or property damage.
CSA B149.1-00 (NSCNGPIC) in Canada; and the Installation Standards, Warm Air Heating and Air Conditioning Systems (NFPA 90B) ANSI/NFPA 90B. In Canada, refer to the CAN/CGA-B/49.1- and .2-M95 National Standard of Canada, Natural Gas and Propane Installation Codes (NSCNGPIC).
WARNING: Turn off the gas and electrical supplies to the unit before performing any maintenance or service. Follow the operating instructions on the label attached to the furnace. Failure to follow this warning could result in personal injury or death.
1. Turn off electrical supply to furnace. 2. Remove main furnace door and blower access panel. 3. Disconnect blower motor wires from furnace control. Field thermostat connections may need to be disconnected depending on their length and routing.
7. Remove screws that secure manifold to burner box. (See Fig. 5.) NOTE: Do not remove burner box from cell panel. 8. Remove manifold, orifices, and gas valve as 1 assembly. 9. Remove screws attaching burner assembly in burner box. 10. Remove burner assembly from burner box.
CAUTION: The ground wire from the gas valve MUST be attached to the burner box attachment screw. Failure to attach this ground wire to an adequate casing ground will cause the furnace control to lock out. NOTE: Be sure burner box gasket is installed between burner box and cell panel.
14. Check furnace operation through 2 complete heat operating cycles. Check area below inducer housing, vent pipe, and condensate trap to ensure no condensate leaks occur.
box or inlet pipe, but can be removed without removing either. After removing screw, slide igniter and bracket toward outside of burner box and pull straight out. CAUTION: The igniter is fragile. DO NOT allow it to hit the side of the burner box opening while removing or replacing it.
1. Turn off electrical supply to furnace. 2. Remove main furnace door. 3. Disconnect cap from unused drain tap on inducer housing. (See Fig. 14.) 4. Connect field-supplied 1/2-in.
1. LED flashes a current status code, or code 11, 4 times. Record this status code for further troubleshooting. 2. The inducer will start and continue to run until test is over. 3. Hot surface igniter (HSI) is energized for 15 sec, then de-energized. 4.
A99118 Fig. 14 — Inducer Housing Drain Tube A99119 Fig. 15 — Funnel in Drain and Antifreeze Running Through Trap — 11 —.
Fig. 16 — Wiring Diagram A02157 PCB TRAN FRS NOTE #11 LS PRS (WHE N USED) LGPS FUSED OR CIRCUIT BREAKER DI SCONNEC T SWI TCH ( WHEN REQ ’ D) NOTE #2 JB L1 L1 BLWR HI/LO TO 115V AC FI ELD DISCONNEC.
Fig. 17 — Service Label A02154 SER VI CE To initiate th e component te st sequence, shut OFF the room thermost at or disconnect the "R" therm ostat lead. Briefl y short the TEST/TWIN ter m inal to the "Com 24V" ter- minal. St atus LED will fl ash code and then tur n ON the i nducer moto r .
A02204a Is LED status light on? Is LED status light blinking rapidly without a pause? Is LED status light blinking ON/OFF slowly with a combination of short and long flashes? Determine status code.
A02204b 11 NO PREVIOUS CODE – Stored codes are erased after 72 hours. On RED LED boards stored status codes can also be erased whene ver pow er (115V or 24V) is interrupted. Run system through a heating or cooling cycle to check system. 12 BLOWER ON AFTER POWER UP – (115V OR 24V) – Normal operation.
© 2002 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 — 16 — Printed in U.S.A. sp0558 Catalog No. 5335-207.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bryant 350MAV c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bryant 350MAV - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bryant 350MAV, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bryant 350MAV va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bryant 350MAV, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bryant 350MAV.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bryant 350MAV. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bryant 350MAV ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.